JBL GTO 14001 (serv.man3) EMC - CB Certificate ▷ View online
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.: HL-S07062713
Page 5 of 28
Page 5 of 28
3 GENERAL
REQUIREMENTS
–
Safety class of the apparatus .................................:
–
4
GENERAL CONDITIONS OF TESTS
–
4.1.4 Ventilation
instructions
require the use of the test box
Tested according to user
instruction.
instruction.
–
5 MARKING
P
Comprehensible and easily discernible
On rear and front side of
the enclosure
the enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / sprit
P
5.1 Identification,
maker,
model ....................................:
Model name: GTO14001 P
Class II symbol if applicable
N
Rated supply voltage and symbol ...........................:
DC12V
P
Frequency if safety dependant
DC supply
N
Rated current or power consumption .....................:
40A*4 1450W
P
5.2
Earth terminal
DC supply
N
Hazardous live terminals
No live parts accessible
N
Supply output terminals (other than mains)
N
5.3
Use of triangle with exclamation mark
The symbol is used in the
circuit diagram. Not used on
components.
circuit diagram. Not used on
components.
N
5.4
Instructions for use
User information in the
following language:
English.
See Summary of Testing.
following language:
English.
See Summary of Testing.
P
5.4.1
Mains powered equipment not exposed to dripping or
splashing. Warning concerning objects filled with
liquid, etc.
splashing. Warning concerning objects filled with
liquid, etc.
P
Hazardous live terminals, instructions for wiring
No live terminals
N
Instructions for replacing lithium battery
No lithium battery
N
Instructions for modem if fitted
No modem used
N
Class I earth connection warning
N
Instructions for multimedia system connection
Adequate instructions
supplied.
supplied.
P
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 6 of 28
Special stability warning for fixed installation
Adequate instructions
supplied.
supplied.
P
Warning: battery exposure to heat
No battery used
N
Warning: protective film on CRT face
No CRT component
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Appliance coupler is
disconnecting device.
Adequate information
included in “User
instruction”
disconnecting device.
Adequate information
included in “User
instruction”
P
Instructions for permanently connected equipment
No permanently connected
apparatus.
apparatus.
P
6 HAZARDOUS
RADIATION
–
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation.
N
6.1
EN 60065
N
6.2
Laser radiation, emission limits to IEC 60825-1 .....:
No laser radiation.
N
Emission limits under fault conditions .....................:
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
–
7.1
Temperature rises not exceeding specified values, no
operation of fuse links
operation of fuse links
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
o
C
The mains supply dc 12V
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 7 of 28
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No changing voltage setting
device
device
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
used
used
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by
hand.
hand.
N
8.5
Class I equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Basic insulation complies
with requirements specified
in clause 10 and 13.
with requirements specified
in clause 10 and 13.
N
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
No resistors bridging basic
insulation.
insulation.
N
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class I appliance
N
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced
insulation complies with
requirements specified in
clause 10 and 13.
insulation complies with
requirements specified in
clause 10 and 13.
N
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus have
isolating transformers
complies with clause 14.3
isolating transformers
complies with clause 14.3
N
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitor.
N
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitor.
N
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
Certified capacitor is
mounted on PCB and
inside enclosure. See
clause 14.
mounted on PCB and
inside enclosure. See
clause 14.
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components
N
8.7
This clause is void
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced
insulation
> 0,4 mm (mm) ....................:
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 8 of 28
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Thin sheet insulation
covered all of power broad
circuit
covered all of power broad
circuit
N
Basic or supplementary insulation, at least two layers,
each meeting 10.3
each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which meet
10.3
10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
N
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
N
8.11
Detaching of wires
N
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
N
Vibration
test carried out .........................................:
–
8.12
This clause is void
N
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N
8.14
Adequate fastening of covers (pull test 50 N for 10 s) No damage in the sense of
this standard
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored
away from parts with high
temp.
away from parts with high
temp.
N
8.16
Only special supply equipment can be used
No special supply
apparatus.
apparatus.
N
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such appliance.
N
8.18
Endurance test as required by 8.17
Test not required.
N
8.19
Disconnection from the mains
Appliance coupler is
disconnection device
disconnection device
P
8.19.1 Disconnect
device
No mains switch
N
Click on the first or last page to see other GTO 14001 (serv.man3) service manuals if exist.