DOWNLOAD JBL GTO 14001 (serv.man3) Service Manual ↓ Size: 889.99 KB | Pages: 29 in PDF or view online for FREE

Model
GTO 14001 (serv.man3)
Pages
29
Size
889.99 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Car Audio
File
gto-14001-sm3.pdf
Date

JBL GTO 14001 (serv.man3) EMC - CB Certificate ▷ View online

 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092    
Report No.: HL-S07062713 
                   Page 5 of 28
 
 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus .................................: 
 
 
 
 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 Ventilation 
instructions 
require the use of the test box
Tested according to user 
instruction. 
 
 
 
 
5 MARKING 
 
Comprehensible and easily discernible 
On rear and front side of 
the enclosure 
 
Permanent durability against water and petroleum 
spirit 
Tested with water / sprit 
5.1 Identification, 
maker, 
model ....................................: 
Model name: GTO14001 P 
 
Class II symbol if applicable 
 
 
Rated supply voltage and symbol ...........................: 
DC12V 
 
Frequency if safety dependant 
DC supply 
 
Rated current or power consumption .....................: 
40A*4 1450W 
5.2 
Earth terminal 
DC supply 
 
Hazardous live terminals 
No live parts accessible 
 
Supply output terminals (other than mains) 
 
5.3 
Use of triangle with exclamation mark 
The symbol is used in the 
circuit diagram. Not used on 
components. 
5.4 
Instructions for use 
User information in the 
following language: 
English. 
See Summary of Testing. 
5.4.1 
Mains powered equipment not exposed to dripping or 
splashing. Warning concerning objects filled with 
liquid, etc. 
 
 
Hazardous live terminals, instructions for wiring 
No live terminals 
 
Instructions for replacing lithium battery 
No lithium battery 
 
Instructions for modem if fitted 
No modem used 
 
Class I earth connection warning 
 
 
Instructions for multimedia system connection 
Adequate instructions 
supplied. 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 6 of 28 
 
Special stability warning for fixed installation 
Adequate instructions 
supplied. 
 
Warning: battery exposure to heat 
No battery used 
 
Warning: protective film on CRT face 
No CRT component 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
Appliance coupler is 
disconnecting device. 
Adequate information 
included in “User 
instruction” 
 
Instructions for permanently connected equipment 
No permanently connected 
apparatus. 
P  
 
 
 
 
6 HAZARDOUS 
RADIATION 
– 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation. 
6.1 
EN 60065 
 N 
6.2 
Laser radiation, emission limits to IEC 60825-1 .....: 
No laser radiation. 
 
Emission limits under fault conditions .....................: 
 
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
– 
7.1 
Temperature rises not exceeding specified values, no 
operation of fuse links 
(see appended table) 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier 
(see appended table) 
7.1.4 
Temperature rise of windings 
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the mains 
carrying a current > 0,2 A at least 150
 o
The mains supply dc 12V 
N  
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 7 of 28 
 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
No changing voltage setting 
device 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic materials 
used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover removable by 
hand. 
8.5 
Class I equipment 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Basic insulation complies 
with requirements specified 
in clause 10 and 13. 
 
Resistors bridging basic insulation complying with 
14.1 a) 
No resistors bridging basic 
insulation. 
8.6 
Class II equipment and Class II constructions within 
Class I equipment 
Class I appliance 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
Double/Reinforced 
insulation complies with 
requirements specified in 
clause 10 and 13. 
N  
 
Components bridging reinforced or double insulation 
complying with 14.1 a) or 14.3 
The apparatus have 
isolating transformers 
complies with clause 14.3 
N  
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a) 
No such capacitor. 
 
 
Reinforced or double insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) 
No such capacitor. 
 
 
Reinforced or double insulation being bridged with a 
single capacitor complying with 14.2.1 b) 
Certified capacitor is 
mounted on PCB and 
inside enclosure. See 
clause 14. 
N  
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such components 
 
8.7 
This clause is void 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
 
 Reinforced 
insulation 
> 0,4 mm (mm)  ....................: 
 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 8 of 28 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
Thin sheet insulation 
covered all of power broad 
circuit  
N  
 
Basic or supplementary insulation, at least two layers, 
each meeting 10.3 
 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N 
 
Reinforced insulation, two layers each of which meet 
10.3 
 
N  
 
Reinforced insulation, three layers any two which 
meet 10.3 
 
N  
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts 
 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts. 
 N 
 
8.11 
Detaching of wires 
 N 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
 N 
 Vibration 
test carried out .........................................: 
 
– 
8.12 
This clause is void 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
 
8.14 
Adequate fastening of covers (pull test 50 N for 10 s)  No damage in the sense of 
this standard 
P  
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges 
Wires safely anchored 
away from parts with high 
temp. 
8.16 
Only special supply equipment can be used 
No special supply 
apparatus. 
8.17 
Insulated winding wire without additional interleaved 
insulation 
No such appliance. 
8.18 
Endurance test as required by 8.17 
Test not required. 
8.19 
Disconnection from the mains 
Appliance coupler is 
disconnection device 
P  
8.19.1 Disconnect 
device 
No mains switch 
Page of 29
Display