JBL GTO 14001 (serv.man3) EMC - CB Certificate ▷ View online
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 21 of 28
20
RESISTANCE TO FIRE
–
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in 20.1 PCB is of flammability class
V-0, and exception is made
for small components.
for small components.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components
comply with flammability
requirements in clause 14.
comply with flammability
requirements in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages > 4 Kv
or leaving an internal fire enclosure, or located within
the areas mentioned in Table 21, not contributing to
the spread of fire
or leaving an internal fire enclosure, or located within
the areas mentioned in Table 21, not contributing to
the spread of fire
No wires working at voltage
> 4kV.
> 4kV.
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better
to IEC60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better
to IEC60707, unless used in a fire enclosure
The PCB is of base material
with flammability category
V-0 (UL approved). See List
of critical components.
with flammability category
V-0 (UL approved). See List
of critical components.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
N
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
Apparatus with voltages >4kV under normal operating
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure.
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure.
N
20.2
Fire enclosure
Metal enclosure
–
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire enclosure
to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire enclosure
to V-1
No voltage > 4 kV (peak)
N
20.2.2
No internal fire enclosure.
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 22 of 28
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an internal
fire enclosure
fire enclosure
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 23 of 28
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
–
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor use
N
A.10.2.1
Enclosure provides protection against splashing
water
water
N
A.10.2.2 Humidity
treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
–
Complies with IEC 62151 clause 1
No TNV circuits
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
–
L5.4
Marking and Instructions
Not applicable
N
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.3.2 of IEC 60086-4
Table 3 , unless comply with 6.3.2 of IEC 60086-4
N
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 24 of 28
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
-
N
Position of the functional switch (W) ................ : -
—
Operating conditions
Testing use 1KHz signal under 1/8 max non clipped output power
Un (V)
In (A)
Pn (W)
Pout (W)
12V 6.83 81.96 -
Loudspeaker impedance (Ω) .............................. : 4
—
Several loudspeaker systems
4
P
Marking of loudspeaker terminals
-
N
Monitored point:
dT (K)
Limit dT (K)
Fuse holder
21.8
-
C53
39.5
80
L3
44.6
75
L5
53.4 75
L10
45.7 75
C106
50.6 80
L9 winding
48.9 75
L9 core
50.9 75
L4
43.2 75
L8 winding
38.9
75
L8 core
39.2
75
C70
52.3 80
PCB near Q27
39.5
80
PCB near Q21
38.5
80
C34
34.6
80
Click on the first or last page to see other GTO 14001 (serv.man3) service manuals if exist.