DOWNLOAD JBL GTO 14001 (serv.man3) Service Manual ↓ Size: 889.99 KB | Pages: 29 in PDF or view online for FREE

Model
GTO 14001 (serv.man3)
Pages
29
Size
889.99 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Car Audio
File
gto-14001-sm3.pdf
Date

JBL GTO 14001 (serv.man3) EMC - CB Certificate ▷ View online

 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 21 of 28 
 
 
 
20 
RESISTANCE TO FIRE 
– 
20.1 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 N 
 
b) Exemption for small components as defined in 20.1 PCB is of flammability class 
V-0, and exception is made 
for small components. 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
Electrical components 
comply with flammability 
requirements in clause 14. 
20.1.2 
Insulation of internal wiring working at voltages > 4 Kv 
or leaving an internal fire enclosure, or located within 
the areas mentioned in Table 21, not contributing to 
the spread of fire 
No wires working at voltage 
> 4kV. 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better 
to IEC60707, unless used in a fire enclosure 
The PCB is of base material 
with flammability category 
V-0 (UL approved). See List 
of critical components. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the distances 
in Table 21 comply with the relevant flammability 
category in Table 21 
 N 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 
 
Apparatus with voltages >4kV under normal operating 
conditions and distances to the enclosure exceed 
those specified Table 21, flammability classification 
HB40 or better is required for the enclosure. 
 
20.2 
Fire enclosure 
Metal enclosure 
– 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire enclosure 
to V-1 
No voltage > 4 kV (peak) 
20.2.2 
No internal fire enclosure. 
 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 22 of 28 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an internal 
fire enclosure 
 
 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 23 of 28 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
– 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
Not intended for outdoor use 
 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
– 
 
Complies with IEC 62151 clause 1 
No TNV circuits 
 
Complies with IEC 62151 clause 2 
 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 
 
Complies with IEC 62151 clause 6  
 
 
Complies with IEC 62151 clause 7  
 
 
Complies with IEC 62151 annex A, B and C 
 
 
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH 
APPARATUS FOR PHOTOGRAPHIC PURPOSES. 
– 
L5.4 
Marking and Instructions 
Not applicable 
L9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE 
 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in 
Table  3 , unless comply with 6.3.2 of IEC 60086-4
 
L14.6.6 
Mains switch characteristics   appropriate to its 
function under normal conditions 
 
 
 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 24 of 28 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
Position of the functional switch (W)  ................ : - 
— 
 
Operating conditions 
Testing use 1KHz signal under 1/8 max non clipped output power 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
12V 6.83 81.96  - 
 
         
 
Loudspeaker impedance (Ω) .............................. : 
— 
         
 
Several loudspeaker systems 
P  
         
 
Marking of loudspeaker terminals 
Monitored point: 
dT (K) 
Limit dT (K) 
Fuse holder 
21.8 
C53 
39.5 
80 
L3 
44.6 
75 
L5 
53.4 75 
L10 
45.7 75 
C106 
50.6 80 
L9 winding 
48.9 75 
L9 core 
50.9 75 
L4 
43.2 75 
L8 winding 
38.9 
75 
L8 core 
39.2 
75 
C70 
52.3 80 
PCB near Q27 
39.5 
80 
PCB near Q21 
38.5 
80 
C34 
34.6 
80 
Page of 29