Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
b) Hazardous live terminals, instructions for wiring   
No hazardous live terminal 
N/A 
 
c) Instructions for replacing lithium battery  
No battery used 
N/A 
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
 
N/A 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
No battery used 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Mains plug is provided 
 
c) Instructions for permanently connected equipment    
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
Hazardous radiation 
  
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No such device 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
...................................................................: 
No such device 
N/A 
 
Emission limits under fault conditions ..................... :   
N/A 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table) 
7.1.1 
Temperature rise of accessible parts  
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table) 
7.1.4 
Temperature rise of windings  
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
Recognized Component is 
provided. 
N/A 
 
Constructional requirements with regard to the protection against electric 
shock 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Windings are covered by 
lacquer 
 
Page 9 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Tools are required 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No such hygroscopic material 
used 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
No such construction 
8.5 
Class I equipment  
  
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
  
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Mains transformer T501 and 
TR1 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
C03 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
Primary wires are double 
insulated 
 
Reinforced insulation > 0,4 mm (mm) .................... : 
 
N/A 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
TIW in TR1 and tape in T501 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 
N/A 
 
Page 10 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Reinforced insulation, three layers any two which 
meet 10.3  
TR1: TIW wire 
T501: TT093050527D-E 
Thin sheet insulation tape with 
a thickness of 0.05 mm. 
And alt. 
T501: TD230-0300E+C 
Thin sheet insulation tape with 
a thickness of 0.08 mm. 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Min. 0.4 mm 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
Min. 0.4 mm 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
See clause 8.9 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
 
8.11 
Detaching of wires  
  
 
No undue reduction of creepages or clearance 
distances if wires become detached  
No risk of any wires detached 
N/A 
 
Vibration test carried out  ........................................ : 
No, no need. See above. 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 
N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
 
 
8.16 
Only special supply equipment can be used  
Not such apparatus 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
Not used 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device  
Mains plug is provided 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
No such devices 
N/A 
8.19.2 
Mains switch ON indication  
Power ON, + green LED 
N/A 
8.20 
Switch not fitted in the mains cord  
  
8.21 
Bridging components comply with clause 14  
C15 (Relay shunt) 
8.22 
Non-separable thin sheet material  
No such material 
N/A 
 
 
Page 11 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1 
a) Open circuit voltages  
 
 
b) Touch current measured from terminal devices 
using the network in annex D ................................. : 
253 V/ 60 Hz 
U1: 0.280 Vpeak max. 
U2: 0.067 Vpeak max. 
 
c) Discharge not exceeding 45 
µ
C  
 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
< 15 KV 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No ventilation holes on top 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No such part 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
  
 
If C is not greater than 0,1 
µ
F no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
  
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
250 N 
9.2 
No hazard after removing a cover by hand  
  
N/A 
 
10 
Insulation requirements 
10.1 
Insulation resistance (M
) at least 2 M
 min. after 
surge test for basic and 4 M
 min. for reinforced 
insulation ................................................................. : 
  
N/A 
10.2 
Humidity treatment 48 h or 120 h  .......................... : 
48 h and 120 h 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 