JBL SUB Brochure ▷ View online
Page 32 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Component
Manufacturer/
trademark
trademark
Type/model Value/rating
Standard
Approval/
reference
reference
1)
AC Inlet
Pronic Electronics
(Shenzhen) Co.,
Ltd.
PST-101
10A, 250 V
DIN EN
60320-1
VDE
Mains Switch
Chily Precision
Industrial Co., Ltd.
3024
16 A, 250 V, 1E4
EN
61058-1
ENEC
AC Connector
(Male)
Jowle Technology
Co., Ltd.
A3693H02-
3P
600 Vac, 7A
EN61984
TUV
AC Connector
(Female)
Jowle Technology
Co., Ltd.
A3963WV2-
3P-D
600 Vac, 7A
EN61984
TUV
PCB
various
various
V-0, 130
°
C
IEC 60065
Tested with
appliance
appliance
Mains Capacitor
(C19)
(across the line)
various
various
X2, 0.22
µ
F, 275 V
IEC 60384-14
2
2
nd
edition
VDE
Mains Capacitor
(C06)
(across the line)
various
various
X2, 0.22
µ
F, 275 V
IEC 60384-14
2
2
nd
edition
VDE
Mains Capacitor
(C15)
(across the line)
various
various
X2, 0.01
µ
F, 275 V
IEC 60384-14
2
2
nd
edition
VDE
Mains Capacitor
(C03)
(single
connected to
accessible
parts)
various
various
Y1, 330 pF, 250 V
IEC 60384-14
2nd edition
2nd edition
VDE
Relay (K1)
Tyco Electronics
EC K.K.
SDT-S-
112LMR
Rated 250 Vac,
5 A, 3 Vdc for coil
TV-5
EN 61810-1
TUV
Secondary
Relay (RY101)
Goodsky
UDH-SS-
124D
12 A / 120 V;
10 A / 250 V
IEC 60065
Tested with
appliance
appliance
Page 33 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Component
Manufacturer/
trademark
trademark
Type/model Value/rating
Standard
Approval/
reference
reference
1)
Optocoupler
(OP1)
Cosmo Electronic
Corporation
K1010
Dti
≥
0,5mm,
external Cr. = 8 mm,
internal Cr. = 5.3 mm
DIN VDE 0884
IEC 60950
VDE
Alt.
Cosmo Electronic
Corporation
KPC817
Dti
≥
0,5mm,
external Cr. = 8 mm,
internal Cr. = 5.3 mm
DIN VDE 0884
IEC 60950
VDE
Transformer
(TR1)
Xin Wnag
Electronics
Industry Co., Ltd.
KB1157-
11486
Class 130
IEC 60065
Tested with
appliance
appliance
-Magnet wire
Hoi Luen
Electrical MFR
Co., Ltd.
XUEW
Alt.
E&B Technology
Co., Ltd.
E&B-XXXB
Rated min. 130°C,
Primary winding:
N1:
Ф
0.2mm X 1P x 61Ts
N4:
Ф
0.2 mm X 1P x
61Ts
N5:
Ф
0.2 mm X 1P x
10Ts
Secondary winding:
N2:
N2:
Ф
0.25mm x 1P X
8Ts
N2:
Ф
0.25mm x 1P X
8Ts
IEC 60065
Tested with
appliance
appliance
- Insulation tape Jing Yahua
Pressure
Sensitive Glue
Co., Ltd.
Sensitive Glue
Co., Ltd.
CT
130
°
C
IEC 60065
Tested with
appliance
appliance
-Bobbin
Chang Chun
Plastics Co., Ltd.
Plastics Co., Ltd.
T375J
V-0, 150
o
C,
Min. 0,75 mm thick
IEC 60065
Tested with
appliance
appliance
-Varnish
Hang Cheung
Petrochemical Ltd.
Petrochemical Ltd.
8562
155
°
C
IEC 60065
Tested with
appliance
appliance
Page 34 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity1)
Shrinking
tubing
tubing
Changyuan
Electronics
(Shenzhen) Co.,
Ltd.
Electronics
(Shenzhen) Co.,
Ltd.
CB-1000
600 Vac, 125
°
C
Applicable
parts of IEC
60065, UL
224
UL recognized
Alt.
Dongguan
Quantai Industrial
Co., Ltd.
Quantai Industrial
Co., Ltd.
T-2
600 Vac, 125
°
C
Applicable
parts of IEC
60065, UL
224
UL recognized
Varistor RV1
(after mains
fuse)
Thinking
Electronic
Industrial Co.,
Ltd.
TVR10471
470 V, 500 A
IEC 61051-2
VDE
Thermistor TR1 Thinking
Electronic
Industrial Co.,
Ltd.
SCK2R55A
5 A
IEC 60065
Tested with
appliance
appliance
Fuse in stand
by power
supply
by power
supply
various
various
T250mA, 250 V
IEC60127
VDE
Amplifier
Plastic Cover
Plastic Cover
Chi Mei
Corporation
Corporation
PA-765 (ABS)
Min.: 3 mm, V-0,
85
o
C
Applicable
parts of IEC
60065, UL 94
UL recognized
Supplementary information:
1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
1) An asterisk indicates a mark which assures the agreed level of surveillance
2) A separately approved power cord that incorporates plugs which complies with the special national
requirements shall be provided with this apparatus when be marketed in the specified countries.
Page 35 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
P
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered to
be equal to the line-to-line voltage, and will remain
230V in case of a single earth fault.
N/A
15.1.1
DK: mains cord for single-phase equipment having a
rated current not exceeding 10 A shall be provided
with a plug according to Heavy Current Regulations
Section 107-2-D1
N/A
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used in
locations where protection against indirect contact is
required shall be provided with a plug in compliance
with Standard Sheet DK 2-1a
No socket outlet
N/A
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 179 of
EN 60 065:2002 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
N/A
DK: mains socket-outlets with earthing contact shall
comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
N/A
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
N/A
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet I page 180 of
EN 60 065:2002
N/A