DOWNLOAD JBL SUB Service Manual ↓ Size: 1.26 MB | Pages: 46 in PDF or view online for FREE

Model
SUB
Pages
46
Size
1.26 MB
Type
PDF
Document
Brochure
Brand
Device
Audio
File
sub.pdf
Date

JBL SUB Brochure ▷ View online

 
Page 12 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 
11 
Fault conditions 
11.1 
No shock hazard under fault condition  
 
11.2 
Heating under fault condition  
 
 
Flames extinguish within 10 seconds  
 
N/A 
 
No hazard from softening solder  
No softening solder 
N/A 
 
Soldered terminations not used as protective 
mechanism  
 
11.2.1 
Measurement of temperature rises  
(see appended table) 
11.2.2 
Temperature rise of accessible parts  
(see appended table) 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
(see appended table) 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
 
11.2.5 
Temperature rise of windings  
(see appended table) 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
  
N/A 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ............... : 
 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 
N/A 
 
Class I protective earthing maintained  
 
N/A 
11.2.7 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.6 shall not exceed the limits in table 3, 
item e), "Fault conditions". 
(see appended table) 
 
12 
Mechanical strength 
 
12.1.1 
Bump test where mass >7 kg  
Measured: 21.2 kg 
12.1.2 
Vibration test  
No connection or part which 
might impair safety can 
become loose 
 
Page 13 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
12.1.3 
Impact hammer test  
  
 
Steel ball test  
  
12.1.4 
Drop test for portable apparatus where mass 
 7 kg    
N/A 
12.1.5 
Thermoplastic enclosures stress relief test  
  
12.2 
Fixing of knobs, push buttons, keys and levers  
 
12.3 
Remote controls with hazardous live parts  
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
 
N/A 
12.6 
Telescoping or rod antennas construction  
 
N/A 
12.6.1 
Telescoping or rod antennas securement  
 
N/A 
 
13 
Clearances and creepage distances 
13.1 
Clearances in accordance with 13.3  
Pollution degree 2 
 
Creepage distances in accordance with 13.4  
Pollution degree 2 and material 
group IIIb 
13.2 
Determination of working voltage  
  
13.3 
Clearances  
 
13.3.1 
General  
 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9............. : 
(see appended table) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
Circuits not conductively 
connected to the mains cannot 
cause any shock hazard 
N/A 
13.3.4 
Measurement of transient voltages  
 
N/A 
13.4 
Creepage distances  
 
 
Creepage distances greater than table 11 minimum 
values  
(see appended table) 
13.5 
Printed boards  
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
No such PCB used 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Page 14 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 
N/A 
 
14 
Components 
 
14.1 
Resistors  
No such components 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
 
N/A 
 
Resistors separately approved  .............................. : 
 
N/A 
14.2 
Capacitors and RC units  
 
N/A 
 
Capacitors separately approved  : 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
Y1: C03 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 
edition ……: 
X2: C06, C15, C19 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... : 
No such components 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better ................. : 
C6, C19 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................ : 
 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal  ....................................................................... : 
 
N/A 
14.3 
Inductors and windings  
  
  
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
  
N/A 
 
Page 15 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  .............................. : 
T501: Transtec  
TT093050527D-E 
Alt. T501: Huizhou GP Wiring 
Technology Ltd. 
TD-230-0300+C 
TR1:  
DW KB1157-11486 
 
Transformers and inductors separately approved  : 
No 
N/A 
14.3.2 
General  
14.3.3, 14.3.4.1 and 14.3.5.1 
 
Insulation material complies with clause 20.1.4  
 
14.3.3 
Constructional requirements  
 
  
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
 
14.3.3.2 
Transformers meet the constructional requirements 
 
14.3.4 
Separation between windings 
 
  
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) ............................. : 
T501: Prim-secondary 
distances: 
TT093050527D-E: 14 mm 
Alt. T501: Prim-sec. 
TD-230-0300E+C: 18 mm 
TR1: Prim.-sec.: > 10 mm 
 
Coil formers and partition walls > 0,4 mm  
TR1: Sec. winding is TIW 
T501: Thin sheet 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
 
N/A 
14.3.4.3 
Separating transformers with at least basic insulation   
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and ACCESSIBLE parts 
  
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
T501: Iron core is floating  
Inside the transformer  
(toroidal transformer) 
TR1: Core not connected to 
accessible parts 
 
Coil formers and partition walls > 0,4 mm  
TR1: Core floating 
T501: Thin sheet tape 
N/A 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
No such transformer 
N/A 
Page of 46
Display

Click on the first or last page to see other SUB service manuals if exist.