JBL SUB Brochure ▷ View online
Page 4 of 36
Report No.: TP11100216-ST
TRF No. IEC60065K
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
authorized by the respective NCBs that own these marks.
(Representative)
Note:
-
The above markings are the minimum requirements required by the safety standard. For the final
production, the additional markings which do not give rise to misunderstanding may be added.
Page 5 of 36
Report No.: TP11100216-ST
TRF No. IEC60065K
Test item particulars ..................................................:
Classification of installation and use ......................: Class II
Supply Connection.....................................................: Mains plug with cord
.......................................................................................:
Possible test case verdicts:
- test case does not apply to the test object........... : N/A (Not Applicable)
- test object does meet the requirement ................. : P (Pass)
- test object does not meet the requirement .......... : F (Fail)
Testing:
Date of receipt of test item ........................................ : Oct. 24, 2011
Date (s) of performance of tests............................... : Nov. 9, 2011 ~ Nov. 20, 2011
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by a NCB, in accordance with IECEE 02.
Throughout this report, a coma is used as the decimal separator.
List of test equipment must be kept on file and available for review.
When determining the test conclusion, the Measurement Uncertainty of test has been considered.
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek. The observations and test results in this report are relevant only to the sample
tested. This report by itself does not imply that the material, product, or service is or has ever been under an
Intertek certification program.
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the
agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek. The observations and test results in this report are relevant only to the sample
tested. This report by itself does not imply that the material, product, or service is or has ever been under an
Intertek certification program.
The test report only allows to be revised only within the report defined retention period unless standard or
regulation was withdrawn or invalid.
Page 6 of 36
Report No.: TP11100216-ST
TRF No. IEC60065K
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test
Certificate includes more than one factory
location and a declaration from the Manufacturer
stating that the sample(s) submitted for
evaluation is (are) representative of the products
from each factory has been provided.......................:
Certificate includes more than one factory
location and a declaration from the Manufacturer
stating that the sample(s) submitted for
evaluation is (are) representative of the products
from each factory has been provided.......................:
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies)...........................: Dongguan Meiloon Acoustic Equipment Co., Ltd.
No. 77, Yuanlin Road, Feng Huang Industrial Estate,
Tangxia, Dongguan, Guangdong Province, 523727,
China
Tangxia, Dongguan, Guangdong Province, 523727,
China
General product information:
The product covered by this Report is a Powered Subwoofer intended for indoor use only. This product is
provided with Mains plug with cord.
provided with Mains plug with cord.
Models SUB550P/230 is identical to Model LS120P/230 except for the enclosure shape.
This test report is based on and entirely replaces Test report with ref. No. 1009955.
Page 7 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3
General requirements
P
Safety class of the apparatus .................................. : Class II
P
4
General test conditions
P
4.1.4
Ventilation instructions require the use of the test box The equipment is located at
the test box and tested.
P
5
Marking and instructions
P
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1
a) Identification, maker ............................................ :
P
b) Model number or type reference.......................... :
LS120P/230 and
SUB550P/230
SUB550P/230
P
c) Class II symbol if applicable ................................ :
P
d) Nature of supply ................................................... :
a.c. only
P
e) Rated supply voltage ........................................... :
220-230 V~
P
f) Mains frequency if safety dependant ................... :
50/60 Hz
P
g) Rated current or power consumption for apparatus
supplied by supply apparatus for general use ........ :
supplied by supply apparatus for general use ........ :
N/A
Measured current or power consumption ............... :
N/A
Deviation % (max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
N/A
Measured current or power consumption ............... :
1 A
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
N/A
Deviation % (max 10%) ........................................... :
P
5.2
a) Earth terminal
N/A
b) Hazardous live terminals
No hazardous live terminal
N/A
c) Markings on supply output terminals
No such terminals
N/A
5.3
a) Use of triangle with exclamation mark
N/A
b) marking on loudspeaker grille, IEC 60417-5036
N/A
5.4
Instructions for use
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
The instruction is provided in
the user manual
the user manual
P
Click on the first or last page to see other SUB service manuals if exist.