JBL SUB 200 EMC - CB Certificate ▷ View online

Page 6 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
e) Instructions for multimedia system connection
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
N/A
g) Warning: battery exposure to heat
N/A
h) Warning: protective film on CRT face
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
Plug. Text in User Instructions.
P
c) Instructions for permanently connected equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
N/A
6
Hazardous radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 …….:
N/A
Emission limits under fault conditions ……………..:
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
o
C
Mains fuse holder
P
8
Constructional requirements with regard to the protection against electric shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
PCB
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
Tools are required.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
Not used.
P
Page 7 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the removal
of a cover which can be removed by hand
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
Mains Transformer and TR1
P
Basic insulation bridged by components complying
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
C3
P
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
N/A
8.7
This clause is void
8.8
Basic or supplementary insulation > 0,4 mm (mm) ...: Primary wires are double
insulated
P
Reinforced insulation > 0,4 mm (mm) ……………….: Mains Transformer bobbin.
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
TIW in TR1
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
TIW in TR1
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
P
Page 8 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
P
Double insulation between conductors connected to
the mains and accessible parts.
Mains wires are double
insulated
P
8.10
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
No secondary wire can come in
to contact with bare live parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
No risk of any wire becoming
detached.
N/A
Vibration test carried out ……………………………:
No, no need. See above.
N/A
8.12
This clause is void
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
In Standby transformer TR1.
P
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
C15
P
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
P
9.1.1.1
a) Open circuit voltages
P
b) Touch current measured from terminal devices
using the network in annex D ………………………:
See Table 9
P
c) Discharge not exceeding 45
μC
N/A
Page 9 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ………………:
0V
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
a) Test probe 11 of IEC 61032 for 10 s (50 N)
P
b) Test hook of fig. 4 for 10 s (20 N)
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
N/A
9.2
No hazard after removing a cover by hand
N/A
10
Insulation requirements
10.1
Insulation resistance (M
Ω) at least 2 MΩmin. after
surge test for basic and 4 M
Ωmin. for reinforced
insulation ………………………………………………..:
N/A
10.2
Humidity treatment 48 h or 120 h …………………….: 48 and 120h. See also page 52.
P
10.3
Insulation resistance and dielectric strength between
mains terminals
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
P
11
Fault conditions
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
P
No hazard from softening solder
P
Soldered terminations not used as protective
mechanism
P
Page of 67