JBL SUB 200 EMC - CB Certificate ▷ View online
Page 30 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Object/Part
No.
No.
Manufacturer
/Trademark
Type/Model
Technical Data2)
Standard
Mark(s) of
Conformity1)
Alt.
Changyuan
Electronics
(Shenzhen) Co.,
Ltd.
102
VW -1
UL224
Com plies with
IEC 60707:HB75
Accepted in
appliance
PCB
Chih Hsien
Enterprise Co. Ltd.
KB-3150 or
CEM-1
94V-0
Complies with
IEC 60707
V-1
—
Alt.
Luen Tai PCB
Factory Co. Ltd.
A126
94V-0
Complies with
IEC 60707
V-1
—
Alt.
Various
Various
Min. V-1
Complies with
IEC 60707
V-1
—
1
) An asterisk indicates a mark which assures the agreed level of surveillance.
2
) Description to include adjacent markings for critical fuse/s.
Page 31 of 54
Report No.: 1009939
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according ....................:
Differences according ....................:
EN 60065:2002 + A1:2006
Attachment Form No. ..................... :
EU_GD_IEC60065J_I
Attachment Form Originator ............. :
Intertek Semko AB
Master Attachment Form .................. :
2009-06
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN)
Clause
Requirement + Test
Result - Remark
Verdict
Contents
Add the following annexes:
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated with portable audio
equipment – Maximum sound pressure level
measurement methodology and limit considerations –
Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with portable audio equipment –
Maximum sound pressure level measurement
methodology and limit considerations – Part 2:
Guidelines to
associate sets with headphones coming from different
manufacturers.
EN 50332-1, Sound system equipment: Headphones
and earphones associated with portable audio
equipment – Maximum sound pressure level
measurement methodology and limit considerations –
Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with portable audio equipment –
Maximum sound pressure level measurement
methodology and limit considerations – Part 2:
Guidelines to
associate sets with headphones coming from different
manufacturers.
P
4.1.1
Replace the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333
50333
.
P
5.1.i)
Add the following note:
NOTE
For RATED POWER CONSUMPTION
measurements of TVs reference is made to EN 60107.
N/A
6.1
Replace the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
N/A
Page 32 of 54
Report No.: 1009939
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
13.3.1
Delete note 4.
P
14
Delete note 4 and note 5.
P
15.1.1
Delete notes 1 and 2.
P
15.2
Delete note 2.
P
16.1
Delete note 1.
P
16.2
Delete the note.
P
20
Delete note 2.
P