JBL SUB 200 EMC - CB Certificate ▷ View online

Page 34 of 54
Report No.: 1009939
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
(normative)
Other international publications quoted in this standard with the references of the relevant
European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of
any of these publications apply to this European Standard only when incorporated in it by
amendment or revision. For undated references the latest edition of the publication referred to
applies (including amendments).
NOTE When an international standard has been modified by common modification, indicated by (mod), the
relevant EN/HD applies.
P
Page 35 of 54
Report No.: 1009939
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Cont.
P
Page 36 of 54
Report No.: 1009939
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex ZA
Cont.
P
GROUP DIFFERENCES FOR AMENDMENT 1
COMMON MODIFICATIONS
5.1 i)
in EN 60065:2002
Replace 
the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is made to
EN 62087. Measurements are done in the ON (play) operating mode.
N/A
5.4.1
Add the following indent:
za) A warning that excessive sound pressure from earphones and headphones can cause
hearing loss.
N/A
6.1
6.1
in EN 60065:2002
Replace 
the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount of
radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1 000 mm
²
or by measuring equipment of other
μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background level.
NOTE These values appear in Directive 96/29/Euratom.
N/A
Bibliography
in EN
60065:2002
Replace the paragraph related to prEN 50332-2 by:
EN 50332-2:2003, Sound system equipment: Headphones and earphones associated with
portable audio equipment - Maximum sound pressure level measurement methodology and
limit
N/A
Page 37 of 54
Report No.: 1009939
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
considerations - Part 2: Matching of sets with headphones if either or both are offered
separately
EN 60065:2002/A1:2006 - 4 -
Bibliograp
hy in IEC
60065:200
1/A1:2005
Add the following notes for the standards indicated:
IEC 60598-2 -9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994 (not modified).
IEC 60598-2 -17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991 (not modified).
P
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1, may
be provided with a plug not establishing earthing
continuity when inserted in Danish socket-outlets
Justification: Heavy Current Regulations, Section
107.
N/A
13.3.1
NO: To the second paragraph the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered to
be equal to the line-to-line voltage, and will remain
230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
P
Page of 67