DOWNLOAD JBL SUB 200 Service Manual ↓ Size: 5.61 MB | Pages: 67 in PDF or view online for FREE

Model
SUB 200
Pages
67
Size
5.61 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-200.pdf
Date

JBL SUB 200 EMC - CB Certificate ▷ View online

Page 22 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
L. 9
Electric shock hazard under normal operating
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
N/A
L.10
Insulation requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
N/A
L. 14
Components
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
N/A
Page 23 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements: Conditions
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W)………..….:…………....:
0 W in off position
P
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1
253
50
0.33
50
9
23
1/8 of max. non-clipping output
power (pink noise)
2
198
50
0.23
30
6.8
13
1/8 of max. non-clipping output
power (pink noise)
Input signal connected to ’Line in L/R’ (See instructions in OM-excerpt on page 5)
Loudspeaker impedance (
Ω) ..................................:
3.5
Ω (measured dc resistance)
Several loudspeaker systems
Marking of loudspeaker terminals
High Level out/in
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 1
No ___
No ___
Iron core of mains transformer
52
-
-
TR1 windings (Measured with thermocouple)
34
75 (65)
Mains wiring (Not under mechanical stress)
28
-
-
60 (50)
PCB -Amp
37
-
-
85 (75)
Inside plastic cover
37
-
-
Heat sink, on rear panel
30
-
-
40 (30)
Rear panel, near control
30
-
-
40 (30)
Buttons (plastic)
19
-
-
50 (40)
Rear enclosure (wood)
25
-
-
60 (50)
PCB – Stand-by PSU
32
85 (75)
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
Ambient temperature t2 (
o
C) ................................
23
26
-
-
-
-
Temperature rise dT of winding:
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(
Ω)
R
2
(
Ω)
dT (K)
Limit
maxK)
Insulation class
Mains Transformer Prim. winding
8.922
11.074
62
85
E
- Sec. winding red-red
0.8583
1.0613
63
85
E
- Sec. winding yellow-yellow
0.4392
0.5461
60
85
E
The values in parenthesis are the limit values for tropical climate.
Page 24 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
-
CLASS I: (single phase)
AC
DC
U1:
Vpk
mA rms
U1:
V
mA
U2:
Vpk
mA rms
CLASS II: (single phase)
U1:
0.24Vpk
mA rms
U1:
V
mA
U2:
0.05Vpk
mA rms
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (M
Ω)
Min
required R
(M
Ω)
Between mains poles (primary fuse disconnected)
>10
≥2
Between parts separated by basic or supplementary insulation
-
-
Between parts separated by double or reinforced insulation
>10
≥4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120 peak
No
Between parts separated by basic or supplementary insulation
-
-
Between parts separated by double or reinforced insulation
4240 peak
No
Page 25 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
11.2
TABLE: summary of fault condition tests
(sc=short circuit;
d=disconnected)
P
Voltage (V) 0.9 or 1.1 times rated voltage ..............:
220-230
Frequency (Hz)……………………………………..:
50-60
Ambient temperature (
o
C) .......................................:
22
No
Component
Fault
Temp Rise/ Component
Other results
(include description and test duration)
1
Max. non-
clipping
output
power
(pink noise)
Pout=100%
(limited)
Test Voltage=253V, Pn=105W, In=0.55A
Steady state after 3h.
No hazard.
2
Q105
sc
--
Test Voltage=198V
Mains fuse opened immediately.
No hazard.
3
Q107
sc
--
Test Voltage=198V
Mains fuse opened immediately. No
hazard.
4
C133
sc
--
Test Voltage=198V
Mains fuse opened immediately. No
hazard.
5a
C122
sc
--
Test Voltage=253V
Mains fuse opened immediately. No
hazard.
5b
C122
sc
--
Test Voltage=198V
Pin=450
→260W, Iin=2.3→1.5A
Printed conductors on the PCB were
interrupted. When the conductors were
bridged the thermal link in the transformer
opened after 3.5 min. No remarks.
6
D115
(
- +)
sc
--
Test Voltage=198V
Mains fuse opened immediately.
No hazard.
7
D110
(
- +)
sc
--
Test Voltage=198V
Mains fuse opened immediately.
No hazard.
8
C117
sc
--
Test Voltage=198V
P
mains
decreased to 8W. No hazard.
9
C10
sc
TR1 winding / 67K
Un=253V, Pn = 5.5W, In = 0.065A
Relay switched OFF.
No Hazard
Page of 67
Display