JBL SPYRO (serv.man3) EMC - CB Certificate ▷ View online
Page 23 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
20
RESISTANCE TO FIRE
N
20.1
Electrical components and mechanical parts
N
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
No potential ignition sources
N
b) Exemption for small components as defined in
20.1
20.1
N
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
N
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
PCB: Min. V-1
N
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
N
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
< 4 kV
N
20.2.2
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N
Page 24 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
N
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N
A.10.2.1
Enclosure provides protection against splashing
water
water
N
A.10.2.2 Humidity
treatment
carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
N
Complies with IEC 62151 clause 1
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
Page 25 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
-
N
Position of the functional switch (W) ...................... : -
-
Operating conditions
- 1/8 clipped output audio power with pink noise input
Un (V)
In(A)
Pin(W)
Pout(W)
18 Vdc
0,57
10,26
0,69 W / CH
for AC/DC adaptor
90 V / 50 Hz
0,287
12,5
0,69 W / CH
90 V / 60 Hz
0,289
12,5
0,69 W / CH
100 V / 50 Hz
0,270
12,4
0,69 W / CH
100 V / 60 Hz
0,268
12,4
0,69 W / CH
240 V / 50 Hz
0,141
12,6
0,69 W / CH
240 V / 60 Hz
0,144
12,6
0,69 W / CH
264 V / 50 Hz
0,131
12,3
0,69 W / CH
264 V / 60 Hz
0,131
12,2
0,69 W / CH
Loudspeaker impedance (Ω) ................................. : Sub woofer: 5
Ω
Satellite speaker: 4
Ω x 2
-
Several loudspeaker systems
--
-
Marking of loudspeaker terminals
--
-
dT (K)
Monitored point:
90V/60Hz
264V/50Hz
Limit dT (K)
1. C100
body
27,4
27,5
50
2. PCB near U17 H/S
40,2
40,4
85
3. C78
body
11,4
11,5
50
4. PCB near U16
24,4
24,6
85
5. Enclosure inside near U17 H/S
19,1
19,1
---
6.
Enclosure outside near U17
H/S
H/S
8,1 9,0
60
7. T1 Coil (AC/DC Adaptor)
11,8
17,5
55
8. Top enclosure (AC/DC Adaptor)
3,3
5,5
60
9. Ambient
( )
℃
24,1
23,9
-
Winding temperature rise measurements
N
Page 26 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
Operating conditions
Ambient temperature t1 (
o
C) .................................. :
-
—
Ambient temperature t2 (
o
C) .................................. :
-
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
- - - - -
Click on the first or last page to see other SPYRO (serv.man3) service manuals if exist.