DOWNLOAD JBL SPYRO (serv.man3) Service Manual ↓ Size: 7.74 MB | Pages: 72 in PDF or view online for FREE

Model
SPYRO (serv.man3)
Pages
72
Size
7.74 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
spyro-sm3.pdf
Date

JBL SPYRO (serv.man3) EMC - CB Certificate ▷ View online

 
Page 19 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
 N 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
 N 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 N 
15.3.6 
Terminals to 15.3.3 have sizes required by 
table 16 
 N 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
Powered 18 Vd.c. by certified 
adaptor 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 N 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 N 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
Powered 18 Vd.c. by certified 
adaptor 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
No non-detachable cord 
 
Terminals located and shielded: test with 8 mm 
strand 
 N 
15.4 
Devices forming a part of the mains plug 
Not devices forming a part of 
the mains plug 
15.4.1 
No undue strain on mains socket-outlets 
 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 N 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 N 
 
 
Page 20 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
16 
EXTERNAL FLEXIBLE CORDS 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ............................................................ :
Not a main powered 
equipment 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
 N 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
 N 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
No interconnection cord 
comprising live voltages 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
No interconnection cord 
comprising live voltages 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
 N 
16.5 
Adequate strain relief on external flexible cords 
No mains cords 
 
Not possible to push cord back into equipment 
 
 
Strain relief device unlikely to damage flexible cord  
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
 N 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
No mains cords 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
No mains cords 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 N 
 
 
Page 21 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
17 ELECTRICAL 
CONNECTIONS AND MECHANICAL FIXINGS 
17.1 
Torque test to table 20: 
No Hazards 
 
- screws into metal: 5 times 
 
 
- screws into non-metallic material: 10 times 
 
17.2 
Correct introduction into female threads in non-
metallic material 
 N 
17.3 
Cover fixing screws: captive 
 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 N 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
 N 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
 N 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
 N 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
 N 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N 
17.9 
 N 
 
 
Page 22 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
Picture tube separately approved to IEC 61965: 
No tube 
 
Picture tube separately approved to 18.1 ...............  
18.1 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 N 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N 
18.3 Non-intrinsically 
protected tubes tested to 18.3 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
Mass of the equipment exceeding 7 kg ................. : 1,6 kg 
 
Apparatus intended to be fastened in place – 
suitable instructions 
 N 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
19.2 
100 N force applied vertically downwards 
 
19.3 
Apparatus mass > 25 kg or height > 1 M or 
supplied with cart or stand 
 N 
19.4 
Edges or corners not hazardous 
No sharp edges or corners 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
 N 
19.6 
Wall or ceiling mountings adequate 
 
 
Page of 72
Display