JBL SPYRO (serv.man3) EMC - CB Certificate ▷ View online
Page 19 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
table 16
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
Powered 18 Vd.c. by certified
adaptor
adaptor
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
Powered 18 Vd.c. by certified
adaptor
adaptor
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
No non-detachable cord
N
Terminals located and shielded: test with 8 mm
strand
strand
N
15.4
Devices forming a part of the mains plug
Not devices forming a part of
the mains plug
the mains plug
N
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N
Page 20 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
16
EXTERNAL FLEXIBLE CORDS
N
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
Not a main powered
equipment
equipment
N
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
N
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
N
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnection cord
comprising live voltages
comprising live voltages
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
No interconnection cord
comprising live voltages
comprising live voltages
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
No mains cords
N
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible cord
N
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
N
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
No mains cords
N
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
No mains cords
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N
Page 21 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
17 ELECTRICAL
CONNECTIONS AND MECHANICAL FIXINGS
N
17.1
Torque test to table 20:
No Hazards
N
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
N
17.2
Correct introduction into female threads in non-
metallic material
metallic material
N
17.3
Cover fixing screws: captive
N
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
N
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
N
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
N
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N
17.8
Fixing devices for detachable legs or stands
provided
provided
N
17.9
N
Page 22 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
N
Picture tube separately approved to IEC 61965:
No tube
N
Picture tube separately approved to 18.1 ...............
N
18.1
Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N
18.3 Non-intrinsically
protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg ................. : 1,6 kg
N
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N
19.1
Test on a plane, inclined at 10
o
to the horizontal
N
19.2
100 N force applied vertically downwards
N
19.3
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
supplied with cart or stand
N
19.4
Edges or corners not hazardous
No sharp edges or corners
P
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
N
19.6
Wall or ceiling mountings adequate
N
Click on the first or last page to see other SPYRO (serv.man3) service manuals if exist.