JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online
Page 3 of 62
Ref. No. : 06-1331-0461
TRF No: IECEN 60065F
TRF originator BEAB
Items covered
1. Model number covered by the scope of this test report is as follows;
1. Model number covered by the scope of this test report is as follows;
Model No.
Descriptions
jbl spot
BASIC model
jbl spyro
The same as basic model, jbl spot, except for satellite speaker
Manufacturer and factory
♦ Manufacturer
Zylux Acoustic Corporation.
12F, 95, Tun Hwa S. Road, Sec. 2, Taipei 106, Taiwan
♦ Factory
Zhao Yang Electronic (Shen Zhen) Co., Ltd.
Ma Bu Technology Park, Xixiang Town, Baoan District, Shenzhen, P.R.C. 518102
Contents
1. Test report : page 1 to 27 of 62
2. National deviations of AR, AT, AU, BE, BR, CA, CH, CN, CS, CZ, DE, DK, FI, FR, GB, GR, HU, IL, IT,
2. National deviations of AR, AT, AU, BE, BR, CA, CH, CN, CS, CZ, DE, DK, FI, FR, GB, GR, HU, IL, IT,
JP, KE, KR, MY, NL, NO, PL, PT, RU, SE, SG, SI, SK, UA and US: Page 28 to 62 of 62
3. ATTACHMENT 1: Photos
4. ATTACHMENT 2: Circuit diagram
5. ATTACHMENT 3: CB certificate of AC/DC adaptor
4. ATTACHMENT 2: Circuit diagram
5. ATTACHMENT 3: CB certificate of AC/DC adaptor
Page 4 of 62
Ref. No. : 06-1331-0461
TRF No: IECEN 60065F
TRF originator BEAB
Copy of marking plate
Page 5 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
3 GENERAL
REQUIREMENTS
N
Safety class of the apparatus ................................. : Fed from AC/DC adaptor
N
4
GENERAL CONDITIONS OF TESTS
P
4.1.4 Ventilation
instructions
require the use of the test
box
Tested in the test box
P
5 MARKING
P
Comprehensible and easily discernible
Compliance checked.
P
Permanent durability against water and petroleum
spirit
spirit
After rubbing test by water and
petroleum spirit, the markings
are still easily discernible,
indelible and legible.
petroleum spirit, the markings
are still easily discernible,
indelible and legible.
P
5.1
Identification, maker, model ................................... : JBL, jbl spot, jbl spyro
P
Class II symbol if applicable
No live voltage in apparatus
N
Rated supply voltage and symbol .......................... : 18 Vdc
P
Frequency if safety dependant
N
Rated current or power consumption .................... : 2,5 A
P
5.2
Earth terminal
No protective earth terminal
N
Hazardous live terminals
No live terminals
N
Supply output terminals (other than mains)
None
N
5.3
Use of triangle with exclamation mark
18Vdc powered equipment
N
5.4
Instructions for use
Installation instruction was
provided in English. Versions
in other languages are to be
provided during the
corresponding national
approval.
provided in English. Versions
in other languages are to be
provided during the
corresponding national
approval.
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
18Vdc powered equipment
N
Hazardous live terminals, instructions for wiring
No Hazards live terminals
N
Instructions for replacing lithium battery
None
N
Instructions for modem if fitted
No modem provided.
N
Class I earth connection warning
No class I apparatus
N
Instructions for multimedia system connection
No multimedia system
connection
connection
N
Special stability warning for fixed installation
< 7 kg
N
Page 6 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
18Vdc powered equipment
N
Instructions for permanently connected equipment Not a permanently connected
N
6 HAZARDOUS
RADIATION
N
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation inside the
EUT.
EUT.
N
6.1
EN 60065
N
6.2
Laser radiation, emission limits to IEC 60825-1 .... : No laser radiation inside the
EUT.
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such components
N