DOWNLOAD JBL SPOT (serv.man3) Service Manual ↓ Size: 7.74 MB | Pages: 72 in PDF or view online for FREE

Model
SPOT (serv.man3)
Pages
72
Size
7.74 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
spot-sm3.pdf
Date

JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online

 
Page 3 of 62 
Ref. No. : 06-1331-0461
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
Items covered 
 
1. Model number covered by the scope of this test report is as follows; 
 
Model No. 
Descriptions 
jbl spot 
BASIC model 
jbl spyro 
The same as basic model, jbl spot, except for satellite speaker 
 
 
Manufacturer and factory 
 
 Manufacturer 
 
 
Zylux Acoustic Corporation. 
 
12F, 95, Tun Hwa S. Road, Sec. 2, Taipei 106, Taiwan  
 
 Factory 
 
 
Zhao Yang Electronic (Shen Zhen) Co., Ltd. 
 
Ma Bu Technology Park, Xixiang Town, Baoan District, Shenzhen, P.R.C. 518102 
 
Contents 
1.  Test report : page 1 to 27 of 62 
2.  National deviations of AR, AT, AU, BE, BR, CA, CH, CN, CS, CZ, DE, DK, FI, FR, GB, GR, HU, IL, IT, 
JP, KE, KR, MY, NL, NO, PL, PT, RU, SE, SG, SI, SK, UA and US: Page 28 to 62 of 62 
3.  ATTACHMENT 1: Photos 
4.  ATTACHMENT 2: Circuit diagram 
5.  ATTACHMENT 3: CB certificate of AC/DC adaptor 
 
 
Page 4 of 62 
Ref. No. : 06-1331-0461
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
Copy of marking plate 
   
 
 
 
 
 
 
Page 5 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
3 GENERAL 
REQUIREMENTS 
 
Safety class of the apparatus ................................. : Fed from AC/DC adaptor 
 
 
 
GENERAL CONDITIONS OF TESTS 
4.1.4 Ventilation 
instructions 
require the use of the test 
box 
Tested in the test box 
 
 
 
5 MARKING 
 
Comprehensible and easily discernible 
Compliance checked. 
 
Permanent durability against water and petroleum 
spirit 
After rubbing test by water and 
petroleum spirit, the markings 
are still easily discernible, 
indelible and legible. 
5.1 
Identification, maker, model  ................................... : JBL, jbl spot, jbl spyro 
 
Class II symbol if applicable 
No live voltage in apparatus 
 
Rated supply voltage and symbol .......................... : 18 Vdc 
 
Frequency if safety dependant 
 
 
Rated current or power consumption .................... : 2,5 A 
5.2 
Earth terminal 
No protective earth terminal 
 
Hazardous live terminals 
No live terminals 
 
Supply output terminals (other than mains) 
None 
5.3 
Use of triangle with exclamation mark 
18Vdc powered equipment 
5.4 
Instructions for use 
Installation instruction was 
provided in English. Versions 
in other languages are to be 
provided during the 
corresponding national 
approval. 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled 
with liquid, etc. 
18Vdc powered equipment 
 
Hazardous live terminals, instructions for wiring 
No Hazards live terminals 
 
Instructions for replacing lithium battery 
None 
 
Instructions for modem if fitted 
No modem provided. 
 
Class I earth connection warning 
No class I apparatus 
 
Instructions for multimedia system connection 
No multimedia system 
connection 
 
Special stability warning for fixed installation 
< 7 kg 
 
Page 6 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
18Vdc powered equipment 
 
Instructions for permanently connected equipment Not a permanently connected  
 
 
6 HAZARDOUS 
RADIATION 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation inside the 
EUT. 
6.1 
EN 60065 
 N 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... : No laser radiation inside the 
EUT. 
 
Emission limits under fault conditions .................... :  
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts 
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table 7.1) 
7.1.4 
Temperature rise of windings 
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No such components 
 
Page of 72