JBL SPARK (serv.man7) EMC - CB Certificate ▷ View online
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 5 of 48
1. TEST RESULT SUMMARY
EN 301 489-17 V2.2.1 &EN 301 489-1 V1.9.2
Standard
Item
Result
Remarks
EN 301 489-17 V2.2.1
&EN 301 489-1 V1.9.2
Conducted Emission
PASS
Meets the Class B requirement
Radiated Emission
PASS
Meets the Class B requirement
Harmonics Current
N/A
Less than 75w
Voltage Fluctuation
and Flicks
PASS
/
EN 301 489-17 V2.2.1 &EN 301 489-1 V1.9.2
Standard
Item
Result
Remarks
EN 61000-4-2:2009
ESD
PASS
Meets the requirements of
Performance Criterion B
EN 61000-4-3: 2006
+A1: 2008+A2: 2010
RS PASS
Meets the requirements of
Performance Criterion A
EN 61000-4-4: 2012
EFT
PASS
Meets the requirements of
Performance Criterion B
EN 61000-4-5:2006
Surge
PASS
Meets the requirements of
Performance Criterion B
EN 61000-4-6:2009
CS
PASS
Meets the requirements of
Performance Criterion A
EN 61000-4-11:2004
Voltage Dips & Short
Interruptions
PASS
Meets the requirements of
Performance Criterion B and C
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 6 of 48
2. GENERAL DESCRIPTION OF TUT
2.1 APPLICANT
Name:
Harman International Industries, Incorporated
Address:
2.2 MANUFACTURER
Name:
Harman International Industries, Incorporated
Address:
2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST
Equipment:
Wireless stereo speaker
Model No.:
JBL SPARK
Trade Name:
JBL
Power supply:
Adapter: Model:F13V-1.7C-DC
Input:AC 100-240V,50/60Hz,0.8A MAX
Output:DC 13V 1.7A
Test Mode
:
Mode 1: BT (EUT is working on Bluetooth connection with mobile phone)
Mode 2: Standby (EUT’s Bluetooth is open and EUT is waiting for pairing with
mobile phone)
Mode 2: Standby (EUT’s Bluetooth is open and EUT is waiting for pairing with
mobile phone)
Sample
submitting way:
submitting way:
■Provided by customer □Sampling
Note: /
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 7 of 48
3. LABORATORY AND ACCREDITATIONS
3.1 LABORATORY
The tests and measurements refer to this report were performed by EMC Laboratory of Guangzhou
GRG Metrology and Test CO., LTD.
Add.
: 163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China
Telephone: +86-20-38699959, 38699960, 38699961
Fax
: +86-20-38695185
3.2 ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies according to
ISO/IEC 17025.
ISO/IEC 17025.
USA
FCC Listed Lab No. 688188
China
CNAS NO.L0446
China
DILAC No.DL175
Canada
Registration No.:8355A-1
3.3 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the EUT as specified in CISPR 16-4-2:
Measurement
Frequency
Uncertainty
Radiated
Emission
Emission
Horizontal 30MHz~1000MHz 4.2dB
Horizontal 1GHz~6GHz 4.2dB
Vertical 30MHz~1000MHz 4.4dB
Vertical 1GHz~6GHz 4.4dB
Horizontal 1GHz~6GHz 4.2dB
Vertical 30MHz~1000MHz 4.4dB
Vertical 1GHz~6GHz 4.4dB
Conducted Emission
9kHz~30MHz 3.1
dB
This uncertainty represents an expanded uncertainty factor of
k=2.
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 8 of 48
3.4 TEST INSTRUMENTS
Name of equipment
Manufacturer
Model
Serial number Calibration due
RE
Receiver R&S
ESU40
100106
2014-01-24
Biconical
Log-periodic Antenna
ETS.LINDGREN
3142C 00075971
2013-05-26
Horn antenna
SCHWARZBECK
BBHA9120D
D752
2013-10-14
CE
EMI Receiver
R&S
ESCI
100529
2013-07-31
L.I.S.N SCHWARZBECK
NSLK
8127
8127450 2013-08-05
ISN TESEQ
ISN-T8
24821
2013-06-02
Harmonics & Flicker
AC Source
California
Instruments
5001ix-400-LF
57549 2013-07-05
Power Analyzer
California
Instruments
PACS-1 72501 2013-07-05
ESD
ESD Tester
EMPEK
ESD-2030A
0230809N
2013-12-14
RS
Signal generator
Rohde & Schwarz
SML03
103002
2013-11-13
Power meter
BOOTON
4232A
10543
2013-09-11
Amplifier
PRANA R&D
AP32 DT214
0611-768
2014-01-11
Amplifier
PRANA R&D
AP32 SV150A
0611-767
2014-01-11
Log-periodic Antenna SCHWARZBECK
STLP 9128 E
9128E-029
2013-05-26
Horn Antenna
SCHWARZBECK
BBHA 9120E BBHA9120E318
2013-10-14
EFT
EFT Generator
EMC PARTNER
TRA2000
853
2014-03-06
EFT Coupling Clamp EMC PARTNER
CN-EFT1000
521
2014-03-06
Surge
Surge Generator
EMC PARTNER
TRA2000
852
2013-08-30
CDN EMC
PARTNER
CDN
2000-06-32
110 2013-05-29
Transient Immunity
Test System
EMC‐
PARTNER
TRANSIENT20
00
845
2013-07-13
Click on the first or last page to see other SPARK (serv.man7) service manuals if exist.