JBL SPARK (serv.man7) EMC - CB Certificate ▷ View online

Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 13 of 48 
 
 
Project No.: 
ZJ00028648 
Polarization: 
Vertical 
Standard: 
(RE)CISPR22 class B _3m_PK 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-5-2 
Temp./Hum.(%RH): 21/50%RH 
Time: 
15:18:31 
EUT: 
JBL Wireless Speaker 
Distance: 
1m 
Model: 
JBL SPARK 
Test Result: 
Pass 
Note:  
Test modeMode 1 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m) 
(dBuV/m) (dBuV/m) 
(dB) 
 
1 3779.012 
34.13 24.92 
59.05 74.00 -14.95 
peak 
2 3779.012 
21.28 24.92 
46.20 54.00 -7.80 AVG 
3 4412.841 
32.72 26.67 
59.39 74.00 -14.61 
peak 
4 4412.841 
19.23 26.67 
45.90 54.00 -8.10 AVG 
5 4782.283 
33.55 27.67 
61.22 74.00 -12.78 
peak 
6 4782.283 
20.53 27.67 
48.20 54.00 -5.80 AVG 
 
Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 14 of 48 
 
 
Project No.: 
ZJ00028648 
Polarization: 
Horizontal 
Standard: 
(RE)CISPR22 class B _3m 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-5-2 
Temp./Hum.(%RH): 21/50%RH 
Time: 
14:52:14 
EUT: 
JBL Wireless Speaker 
Distance: 
3m 
Model: 
JBL SPARK 
Test Result: 
Pass 
Note:  
Test modeMode 1 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m) 
(dBuV/m) (dBuV/m) 
(dB) 
 
1 30.0000 
3.07  19.43 
22.50 40.00 -17.50 
QP 
2 31.0288 
1.71  18.79 
20.50 40.00 -19.50 
QP 
3 43.2269 
4.71  12.19 
16.90 40.00 -23.10 
QP 
4 97.6401 
9.57  9.93 
19.50 40.00 -20.50 
QP 
5 151.3521 
6.18  10.22 
16.40 40.00 -23.60 
QP 
6 321.3783 
11.99 16.31 
28.30 47.00 -18.70 
QP 
 
Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 15 of 48 
 
 
Project No.: 
ZJ00028648 
Polarization: 
Horizontal 
Standard: 
(RE)CISPR22 class B _3m_PK 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-5-2 
Temp./Hum.(%RH): 21/50%RH 
Time: 
15:22:45 
EUT: 
JBL Wireless Speaker 
Distance: 
1m 
Model: 
JBL SPARK 
Test Result: 
Pass 
Note:  
Test modeMode 1 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m) 
(dBuV/m) (dBuV/m) 
(dB) 
 
1 1610.676 
35.24 12.26 
47.50 70.00 -22.50 
peak 
2 1610.676 
21.94 12.26 
34.20 50.00 -15.80 
AVG 
3 4025.437 
32.84 25.60 
58.44 74.00 -15.56 
peak 
4 4025.437 
19.50 25.60 
45.10 54.00 -8.90 AVG 
5 4865.389 
34.80 27.89 
62.69 74.00 -11.31 
peak 
6 4865.389 
20.21 27.89 
48.10 54.00 -5.90 AVG 
 
 
 
Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 16 of 48 
 
4.2 CONDUCTED EMISSION MEASUREMENT 
4.2.1 LIMITS 
AC Power port 
Frequency (MHz) 
Quasi-peakdBμV) 
AveragedBμV 
0.15 ~ 0.5 
66~56 56~46 
0.5 ~ 5 
56 46 
5 ~ 30 
60 
50 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
Telecommunication ports 
Frequency (MHz) 
Quasi-peakdBμV) 
AveragedBμV 
0.15 ~ 0.5 
84~74 74~64 
0.5 ~ 30 
74 64 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
Telecommunication ports 
4.2.2 TEST PROCEDURES 
Procedure of Preliminary Test 
For measurement of the disturbance voltage the equipment under test (EUT) is connected to 
the power supply mains and any other extended network via one or more artificial network(s). 
An EUT, whether intended to be grounded or not, and which is to be used on a table is 
configured as follows: 
–   Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a 
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It 
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as 
follows: 
1)  place the EUT on a table of non-conducting material which is at least 80 cm high. Place the 
EUT so that it is 40 cm from the wall of the shielded room, or 
2)  place the EUT on a table of non-conducting material which is 40 cm high so that the 
bottom of the EUT is 40 cm above the ground plane; 
–    All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground 
plane; 
–    The ANs are placed on the floor that one side of the AN housings is 40 cm from the 
vertical reference ground plane and other metallic parts; 
–    Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded 
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle 
between the ground plane and the table. 
–    I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the 
cable may be terminated if required using correct terminating impedance. The total length 
shall not exceed 1 m. 
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the 
preliminary scan, we found the test mode described in Item 2.4 producing the highest 
emission level. The EUT configuration and cable configuration of the above highest emission 
Page of 48