Report No.: EM201300221-2 Application No.: ZJ00028648 Page 13 of 48
Project No.:
ZJ00028648
Polarization:
Vertical
Standard:
(RE)CISPR22 class B _3m_PK
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-5-2
Temp./Hum.(%RH): 21/50%RH
Time:
15:18:31
EUT:
JBL Wireless Speaker
Distance:
1m
Model:
JBL SPARK
Test Result:
Pass
Note:
Test mode:Mode 1
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m) (dBuV/m)
(dB)
1 3779.012
34.13 24.92
59.05 74.00 -14.95
peak
2 3779.012
21.28 24.92
46.20 54.00 -7.80 AVG
3 4412.841
32.72 26.67
59.39 74.00 -14.61
peak
4 4412.841
19.23 26.67
45.90 54.00 -8.10 AVG
5 4782.283
33.55 27.67
61.22 74.00 -12.78
peak
6 4782.283
20.53 27.67
48.20 54.00 -5.80 AVG
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 14 of 48
Project No.:
ZJ00028648
Polarization:
Horizontal
Standard:
(RE)CISPR22 class B _3m
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-5-2
Temp./Hum.(%RH): 21/50%RH
Time:
14:52:14
EUT:
JBL Wireless Speaker
Distance:
3m
Model:
JBL SPARK
Test Result:
Pass
Note:
Test mode:Mode 1
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m) (dBuV/m)
(dB)
1 30.0000
3.07 19.43
22.50 40.00 -17.50
QP
2 31.0288
1.71 18.79
20.50 40.00 -19.50
QP
3 43.2269
4.71 12.19
16.90 40.00 -23.10
QP
4 97.6401
9.57 9.93
19.50 40.00 -20.50
QP
5 151.3521
6.18 10.22
16.40 40.00 -23.60
QP
6 321.3783
11.99 16.31
28.30 47.00 -18.70
QP
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 15 of 48
Project No.:
ZJ00028648
Polarization:
Horizontal
Standard:
(RE)CISPR22 class B _3m_PK
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-5-2
Temp./Hum.(%RH): 21/50%RH
Time:
15:22:45
EUT:
JBL Wireless Speaker
Distance:
1m
Model:
JBL SPARK
Test Result:
Pass
Note:
Test mode:Mode 1
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m) (dBuV/m)
(dB)
1 1610.676
35.24 12.26
47.50 70.00 -22.50
peak
2 1610.676
21.94 12.26
34.20 50.00 -15.80
AVG
3 4025.437
32.84 25.60
58.44 74.00 -15.56
peak
4 4025.437
19.50 25.60
45.10 54.00 -8.90 AVG
5 4865.389
34.80 27.89
62.69 74.00 -11.31
peak
6 4865.389
20.21 27.89
48.10 54.00 -5.90 AVG
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 16 of 48
4.2 CONDUCTED EMISSION MEASUREMENT
4.2.1 LIMITS
AC Power port
Frequency (MHz)
Quasi-peak(dBμV)
Average(dBμV)
0.15 ~ 0.5
66~56 56~46
0.5 ~ 5
56 46
5 ~ 30
60
50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 ~0.5 MHz.
Telecommunication ports
Frequency (MHz)
Quasi-peak(dBμV)
Average(dBμV)
0.15 ~ 0.5
84~74 74~64
0.5 ~ 30
74 64
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 ~0.5 MHz.
Telecommunication ports
4.2.2 TEST PROCEDURES
Procedure of Preliminary Test
For measurement of the disturbance voltage the equipment under test (EUT) is connected to
the power supply mains and any other extended network via one or more artificial network(s).
An EUT, whether intended to be grounded or not, and which is to be used on a table is
configured as follows:
For measurement of the disturbance voltage the equipment under test (EUT) is connected to
the power supply mains and any other extended network via one or more artificial network(s).
An EUT, whether intended to be grounded or not, and which is to be used on a table is
configured as follows:
– Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as
follows:
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as
follows:
1) place the EUT on a table of non-conducting material which is at least 80 cm high. Place the
EUT so that it is 40 cm from the wall of the shielded room, or
EUT so that it is 40 cm from the wall of the shielded room, or
2) place the EUT on a table of non-conducting material which is 40 cm high so that the
bottom of the EUT is 40 cm above the ground plane;
bottom of the EUT is 40 cm above the ground plane;
– All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground
plane;
plane;
– The ANs are placed on the floor that one side of the AN housings is 40 cm from the
vertical reference ground plane and other metallic parts;
vertical reference ground plane and other metallic parts;
– Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle
between the ground plane and the table.
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle
between the ground plane and the table.
– I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the
cable may be terminated if required using correct terminating impedance. The total length
shall not exceed 1 m.
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the
preliminary scan, we found the test mode described in Item 2.4 producing the highest
emission level. The EUT configuration and cable configuration of the above highest emission
cable may be terminated if required using correct terminating impedance. The total length
shall not exceed 1 m.
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the
preliminary scan, we found the test mode described in Item 2.4 producing the highest
emission level. The EUT configuration and cable configuration of the above highest emission
Click on the first or last page to see other SPARK (serv.man7) service manuals if exist.