Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 29 of 48 
 
 
5.4.3 TEST SETUP 
 
 
 
 
 
 
 
 
 
 
 
                                 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Power 
Amp 
Signal 
Generato
r
EUT Monitoring by 
using a spectrum and 
ear
 
0.8m
Control Room
9
×
6
×
EUT& 
Support 
Units 
PC Controller to 
control S.G. & PA as 
well as forward 
power
 
3 meter 
1.5m 
Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 30 of 48 
 
 
5.4.4 TEST RESULTS 
EUT 
JBL Wireless Speaker 
Mode Number 
JBL SPARK 
Test date 
2013-05-03 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Liang 
environment 
Tem:22℃ Hum:54 %100kPa 
Test mode: 
1. Test the EUT in mode 1:BT  
2. Test the EUT in mode 2:Standby 
 
Frequency  
(MHz) 
Polarity 
Azimuth 
Field 
Strength
(V/m)
Required 
Passing 
Performance 
Actual 
performance
Result
80 ~ 1000 
V&H 
Front 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Rear 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Right 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Left 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Front 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Rear 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Right 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Left 
Criterion A 
Criterion A* PASS
A*EUT is working on intended use operation, no abnormal phenomenon was observed.
Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 31 of 48 
 
 
5.5 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 
5.5.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-4: 2012 
Test Voltage 
Electrical Fast Transient/Burst – EFT: 
AC Power Port: ±1kV,Signal port ±0.5kV 
Performance Criterion B 
Polarity 
Positive and Negative 
Impulse Frequency 
5 kHz 
Impulse Wave-shape 
5 ns/50ns for voltage  
Burst Duration 
15 ms 
Burst Period 
300 ms 
Test Duration 
2 minutes 
5.5.2 TEST PROCEDURE  
 
The EUT and its simulators shall be placed 0.1m high above the ground reference plane which is a min. 
1m×1m metallic sheet with 0.65mm minimum thickness. This reference ground plane shall project 
beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other 
conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m. 
For input and AC power ports
The EUT is connected to the power mains by using a coupling device which couples the EFT 
interference signal to AC power lines. Both polarities of the test voltage should be applied during 
compliance test and the duration of the test can’t less than 1min. 
5.5.3 TEST SETUP 
 
 
 
 
 
10 cm isolation 
supporter 
AC
 input 
EFT 
Generator 
EUT 
AC
  
AC Line 
Ground Reference Plane 
0.5m
Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 32 of 48 
 
 
5.5.4 TEST RESULTS 
EUT 
JBL Wireless Speaker 
Mode Number 
JBL SPARK 
Test date 
2013-05-03 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Liang 
environment 
Tem:21℃ Hum:54 %100kPa 
Test mode: 
1. Test the EUT in mode 1:BT  
2. Test the EUT in mode 2:Standby 
 
Test Point 
Polarity 
Test Level 
(kV) 
Required Passing 
Performance 
Actual 
performance 
Result 
L–N 
+/- 
Criterion B 
Criterion A* 
PASS 
A*EUT is working on intended use operation, no abnormal phenomenon was observed. 
 