DOWNLOAD JBL SDP-5 (serv.man7) Service Manual ↓ Size: 3.09 MB | Pages: 127 in PDF or view online for FREE

Model
SDP-5 (serv.man7)
Pages
127
Size
3.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
sdp-5-sm7.pdf
Date

JBL SDP-5 (serv.man7) Service Manual ▷ View online

Lexicon 
Signal-to-Noise Ratio*   >65dB 
 
Frequency Response*   
10Hz to 10MHz + 0.1/-0.3dB 
Component Video Performance 
Compatibility 
 
  3-Channel 
(Y/Pb/Pr), format-independent 
 
Switching 
 
  Passive 
 
Impedance  
 
 
75
Ω 
 
 
Bandwidth  
 
 
>150MHz 
 
Insertion Loss*  
 
<3dB 
 
Microphone Input Connectors (For V2 and Higher Units) 
Input    
 
 
4 3.5 miniature phone jacks 
 
Input Sensitivity 
 
10mVrms (400mV maximum input level) 
 
Input Impedance   20k
Ω (accepts balanced or unbalanced input signals) 
 
Other
 
Trigger Outputs  
1 power on/off and 1 programmable connector on detachable screw 
terminals (+12 VDC, 0.5 amps each) 
 
RS-232 Serial Input/Output  
2 9-pin D-sub connectors 
 
Power Requirements  
90-250 VAC, 50-60Hz, 60W (universal line input), detachable power cord 
 
MC-8 Dimensions & Weight 
Height (with feet): 3.81 inches (97mm) 
Width: 17.3 inches (440mm) 
Depth: 14.85 inches (377mm) 
Weight: 17lb (7.6kg) 
 
 
 
 
3-3
MC-8 Service Manual 
MC-8 Balanced Dimensions & Weight 
Height (with feet): 5.04 inches (128mm) 
Width: 17.3 inches (440mm) 
Depth: 14.85 inches (377mm) 
Weight: 24lb (10.7kg) 
Rack Mounting  
Optional brackets are available for installation in a standard 19" 
equipment rack (2 rack units required for MC-8; 3 rack units for MC-8 
Balanced) 
 
Environment 
  Operating 
Temp: 0° to 35°C (32° to 95°F) 
 
 
Storage Temp: -30° to 75°C (-22° to 167°F) 
 
Relative Humidity: 95% maximum without condensation 
 
Remote Control  
 
Hand-held, backlit infrared remote control unit, preprogrammed & 
 learning 
 
Requires two AA batteries (alkaline batteries recommended) 
 
 
*
Specifications are subject to change without notice. 
 
 
3-4
Lexicon 
CHAPTER 4 – FUNCTIONAL VERIFICATION  
PERFORMANCE VERIFICATION 
This section describes a quick verification of the operation of the MC-8 and the integrity of its analog and 
digital audio signal paths. Tests that are specifically included for the MC-8 Balanced version can be 
omitted when testing an MC-8. 
WARNING
 
Dangerous voltages capable of causing death are present in this unit. Use extreme 
caution when handling, testing, or adjusting. Always power down all equipment before 
breaking/making connections.  
Initial Inspection 
1.  Inspect the MC-8 for obvious signs of physical abuse. 
2.  Verify that all switches operate smoothly. 
3.  With the power off for ten minutes and the AC cord disconnected, remove the MC-8 top cover using a 
hex wrench (2.5mm). Remove the 13 screws on the top cover of the unit to remove the cover. 
4.  Verify that all socketed ICs are correctly seated. 
5.  Verify that all cables are correctly installed and are securely fastened. 
6.  Check for burnt or obviously damaged components. 
7.  Put the top cover back on.  
8.  Power on the MC-8 using the main power switch on the back of the unit, and verify that the MC-8 
runs through its Power On Diagnostics. 
9.  Check each of the front panel switches for smooth mechanical operation, verify each LED turns on 
and off when the associated switch is depressed, and that the display acknowledges each switch 
function. 
10.  Press each button on the remote and verify that the MC-8 is responding to all the remote commands. 
 
 
 
 
 
 
 
 
 
4-1
MC-8 Service Manual 
FUNCTIONAL AUDIO I/O TESTS 
The following tests verify the basic functions of the MC-8. 
Power Supply Tests 
 
Lethal voltages capable of causing death are present in this unit. In this procedure, 
testing will be performed with the top cover removed and the unit turned on. Due to risk 
of shock, do not remove the cover with the unit powered on.
 
Test: 
1.  Set the variable AC supply to 120 volts. 
2.  Verify that the MC-8 is powered off at its rear panel power switch. 
3.  Connect the power cord between the supply and the MC-8. 
4.  Remove the top cover. 
5.  Check for power supply shorts to ground.  
6.  Turn on the MC-8 using the rear main power switch. 
7.  Power on the unit at 120VAC. 
8.  Verify the current draw on the Variac does not exceed 0.6 amps.  
9.  Using a DMM, measure all the power supply rails as stated in the tables below, being sure to use the 
MC-8 chassis as ground. 
10.  Verify that all the voltages are within the tolerance range shown below. 
 
Main Board 
Supply Rail 
Tolerance 
Test Points 
+5VD 
4.75 - 5.25 
Red wire at J45 behind front panel center at volume 
knob left to ground 
Battery 
≥ 2.5 
Right side to the Left of U69, measure the top of the 
battery to ground 
+15V 
15.00 - 16.95 
Yellow wire at J32 to ground 
-15V 
-14.25 - 15.75 
Blue wire at J32 to ground 
+5VAD 
4.75 - 5.25 
Red wire at J32 to ground 
-5VA 
-4.75 - 5.25 
Gray wire at J32 to ground 
 
 