JBL SDP-5 (serv.man7) Service Manual ▷ View online
Lexicon
Signal-to-Noise Ratio* >65dB
Frequency Response*
Frequency Response*
10Hz to 10MHz + 0.1/-0.3dB
Component Video Performance
Compatibility
3-Channel
(Y/Pb/Pr), format-independent
Switching
Passive
Impedance
75
Ω
Bandwidth
>150MHz
Insertion Loss*
<3dB
Microphone Input Connectors (For V2 and Higher Units)
Input
4 3.5 miniature phone jacks
Input Sensitivity
10mVrms (400mV maximum input level)
Input Impedance 20k
Ω (accepts balanced or unbalanced input signals)
Other
Trigger Outputs
1 power on/off and 1 programmable connector on detachable screw
terminals (+12 VDC, 0.5 amps each)
terminals (+12 VDC, 0.5 amps each)
RS-232 Serial Input/Output
2 9-pin D-sub connectors
Power Requirements
90-250 VAC, 50-60Hz, 60W (universal line input), detachable power cord
MC-8 Dimensions & Weight
Height (with feet): 3.81 inches (97mm)
Width: 17.3 inches (440mm)
Depth: 14.85 inches (377mm)
Weight: 17lb (7.6kg)
3-3
MC-8 Service Manual
MC-8 Balanced Dimensions & Weight
Height (with feet): 5.04 inches (128mm)
Width: 17.3 inches (440mm)
Depth: 14.85 inches (377mm)
Weight: 24lb (10.7kg)
Rack Mounting
Optional brackets are available for installation in a standard 19"
equipment rack (2 rack units required for MC-8; 3 rack units for MC-8
Balanced)
equipment rack (2 rack units required for MC-8; 3 rack units for MC-8
Balanced)
Environment
Operating
Temp: 0° to 35°C (32° to 95°F)
Storage Temp: -30° to 75°C (-22° to 167°F)
Relative Humidity: 95% maximum without condensation
Remote Control
Hand-held, backlit infrared remote control unit, preprogrammed &
learning
Requires two AA batteries (alkaline batteries recommended)
*
Specifications are subject to change without notice.
3-4
Lexicon
CHAPTER 4 – FUNCTIONAL VERIFICATION
PERFORMANCE VERIFICATION
This section describes a quick verification of the operation of the MC-8 and the integrity of its analog and
digital audio signal paths. Tests that are specifically included for the MC-8 Balanced version can be
omitted when testing an MC-8.
digital audio signal paths. Tests that are specifically included for the MC-8 Balanced version can be
omitted when testing an MC-8.
WARNING
Dangerous voltages capable of causing death are present in this unit. Use extreme
caution when handling, testing, or adjusting. Always power down all equipment before
breaking/making connections.
caution when handling, testing, or adjusting. Always power down all equipment before
breaking/making connections.
Initial Inspection
1. Inspect the MC-8 for obvious signs of physical abuse.
2. Verify that all switches operate smoothly.
3. With the power off for ten minutes and the AC cord disconnected, remove the MC-8 top cover using a
hex wrench (2.5mm). Remove the 13 screws on the top cover of the unit to remove the cover.
4. Verify that all socketed ICs are correctly seated.
5. Verify that all cables are correctly installed and are securely fastened.
6. Check for burnt or obviously damaged components.
7. Put the top cover back on.
8. Power on the MC-8 using the main power switch on the back of the unit, and verify that the MC-8
runs through its Power On Diagnostics.
9. Check each of the front panel switches for smooth mechanical operation, verify each LED turns on
and off when the associated switch is depressed, and that the display acknowledges each switch
function.
function.
10. Press each button on the remote and verify that the MC-8 is responding to all the remote commands.
4-1
MC-8 Service Manual
FUNCTIONAL AUDIO I/O TESTS
The following tests verify the basic functions of the MC-8.
Power Supply Tests
Lethal voltages capable of causing death are present in this unit. In this procedure,
testing will be performed with the top cover removed and the unit turned on. Due to risk
of shock, do not remove the cover with the unit powered on.
testing will be performed with the top cover removed and the unit turned on. Due to risk
of shock, do not remove the cover with the unit powered on.
Test:
1. Set the variable AC supply to 120 volts.
2. Verify that the MC-8 is powered off at its rear panel power switch.
3. Connect the power cord between the supply and the MC-8.
4. Remove the top cover.
5. Check for power supply shorts to ground.
6. Turn on the MC-8 using the rear main power switch.
7. Power on the unit at 120VAC.
8. Verify the current draw on the Variac does not exceed 0.6 amps.
9. Using a DMM, measure all the power supply rails as stated in the tables below, being sure to use the
MC-8 chassis as ground.
10. Verify that all the voltages are within the tolerance range shown below.
Main Board
Supply Rail
Tolerance
Test Points
+5VD
4.75 - 5.25
Red wire at J45 behind front panel center at volume
knob left to ground
knob left to ground
Battery
≥ 2.5
Right side to the Left of U69, measure the top of the
battery to ground
battery to ground
+15V
15.00 - 16.95
Yellow wire at J32 to ground
-15V
-14.25 - 15.75
Blue wire at J32 to ground
+5VAD
4.75 - 5.25
Red wire at J32 to ground
-5VA
-4.75 - 5.25
Gray wire at J32 to ground
4-2