JBL SB 400 (serv.man4) EMC - CB Certificate ▷ View online
Page 5 of 62
Report No.: 085-120207501-000
TRF No. IEC60065K Jiangsu TÜV Product Service Ltd. Guangzhou Branch
Test item particulars .................................................. :
Classification of installation and use ...................... : Class II moveable equipment
Supply Connection .................................................... : Appliance inlet
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A (Not Applicable)
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing:
Date of receipt of test item......................................... : 2012-09-11
Date (s) of performance of tests ............................... : 2012-09-11 to 2012-11-21
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Guoguang Electric Co., Ltd.
No.8 JingHu Road Xinhua Town 510800 Huadu
Reg, Guangzhou PEOPLE'S REPUBLIC OF CHINA
Reg, Guangzhou PEOPLE'S REPUBLIC OF CHINA
General product information:
1. The apparatus is including center & subwoofer, there is two 4
speakers and four 8
speakers housed
in the enclosure of center, there is one 8
speakers housed in the enclosure of subwoofer. Bluetooth
Pairing between the center and the wireless subwoofer.There are 2 sources of power board in the
center and subwoofer. The two sources of power board are identical with size and function except
schematic and PCB layout.
schematic and PCB layout.
Power board of two sources factory:
Factory1: Foshan Hanwei Electron Co., Ltd.
Factory2: Shenzhen Jingquanhua (JQH) Electronics Co., Ltd.
Factory2: Shenzhen Jingquanhua (JQH) Electronics Co., Ltd.
2. The apparatus is intended for indoor use only.
3. The max. ambient temperature is 35°C.
Page 6 of 62
Report No.: 085-120207501-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K Jiangsu TÜV Product Service Ltd. Guangzhou Branch
3
General requirements
P
Safety class of the apparatus .................................. : Class II apparatus.
P
4
General test conditions
P
4.1.4
Ventilation instructions require the use of the test
box
box
Yes
P
5
Marking and instructions
P
Comprehensible and easily discernible
All markings are printed on outer
enclosures of the appliance.
enclosures of the appliance.
P
Permanent durability against water and petroleum
spirit
spirit
After rubbing test by water and
petroleum spirit, the markings are
still easily discernible, indelible
and legible.
petroleum spirit, the markings are
still easily discernible, indelible
and legible.
P
5.1
a) Identification, maker ............................................ : Trademark and model no. are
marked on the outer enclosure.
P
b) Model number or type reference .......................... : Cinema SB400
P
c) Class II symbol if applicable ................................ : See marking plate
P
d) Nature of supply .................................................... :
~
P
e) Rated supply voltage ........................................... : For center: 100-240V~
For subwoofer: 100-240V~
P
f) Mains frequency if safety dependant ................... : For center: 50/60Hz
For subwoofer: 50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................ :
apparatus supplied by supply apparatus for general
use ............................................................................ :
N/A
Measured current or power consumption ............... :
N/A
Deviation % (max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
For center: 100 W
For subwoofer: 100 W
P
Measured current or power consumption ............... : (See appended table 7.1)
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
N/A
Deviation % (max 10%) ........................................... : (See appended table 7.1)
P
5.2
a) Earth terminal
N/A
b) Hazardous live terminals
No such terminals provided.
N/A
c) Markings on supply output terminals
No such terminals provided.
N/A
5.3
a) Use of triangle with exclamation mark
P
b) marking on loudspeaker grille, IEC 60417-5036
N/A
Page 7 of 62
Report No.: 085-120207501-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K Jiangsu TÜV Product Service Ltd. Guangzhou Branch
5.4
Instructions for use
English.
Instruction in other language shall
be provided when national
approvals.
Instruction in other language shall
be provided when national
approvals.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
See user manual.
P
b) Hazardous live terminals, instructions for wiring
No such terminals provided
N/A
c) Instructions for replacing lithium battery
No batteries provided
N/A
d) Class I earth connection warning
N/A
e) Instructions for multimedia system connection
Not multimedia system.
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
N/A
g) Warning: battery exposure to heat
No batteries provided
N/A
h) Warning: protective film on CRT face
No CRT provided
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
The appliance inlet was used as
disconnect device. See user
manual.
disconnect device. See user
manual.
P
c) Instructions for permanently connected equipment Not permanently connected
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6
Hazardous radiation
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation inside the
EUT.
EUT.
N/A
Ionizing radiation under fault condition
See above.
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
................................................................................... :
................................................................................... :
No laser radiation inside the EUT.
N/A
Emission limits under fault conditions ..................... : See above.
N/A
7
Heating under normal operating conditions
P
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
Page 8 of 62
Report No.: 085-120207501-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K Jiangsu TÜV Product Service Ltd. Guangzhou Branch
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
N/A
8
Constructional requirements with regard to the protection against electric shock
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such material used
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No cover can be removed.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used.
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
No such cover which can be
removed by hand.
removed by hand.
N/A
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
See below.
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Secondary circuit to primary
circuit is separated by reinforced
or double insulation. (The
insulation system of input
transformer is double insulation
system).
circuit is separated by reinforced
or double insulation. (The
insulation system of input
transformer is double insulation
system).
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The switching transformer has
been tested during this approval
been tested during this approval
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Click on the first or last page to see other SB 400 (serv.man4) service manuals if exist.