Page 5 of 62 
 
Report No.: 085-120207501-000 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
  
Test item particulars .................................................. :   
Classification of installation and use ...................... :  Class II moveable equipment 
Supply Connection .................................................... :  Appliance inlet  
Possible test case verdicts: 
 
- test case does not apply to the test object ........... :  N/A (Not Applicable) 
- test object does meet the requirement .................. :  P (Pass) 
- test object does not meet the requirement ........... :  F (Fail) 
Testing: 
 
Date of receipt of test item......................................... :  2012-09-11 
Date (s) of performance of tests ............................... :  2012-09-11 to 2012-11-21 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test Certificate 
includes more than one factory location and a 
declaration from the Manufacturer stating that the 
sample(s) submitted for evaluation is (are) 
representative of the products from each factory 
has been provided ...................................................... : 
 Yes 
 Not applicable 
When differences exist; they shall be identified in the General product information section. 
Name and address of factory (ies) .......................... :  Guoguang Electric Co., Ltd. 
No.8 JingHu Road Xinhua Town 510800 Huadu 
Reg, Guangzhou PEOPLE'S REPUBLIC OF CHINA
 
General product information: 
1. The apparatus is including center & subwoofer, there is two 4
 speakers and four 8
 speakers housed   
     in the enclosure of center, there is one 8
 speakers housed in the enclosure of subwoofer. Bluetooth   
     Pairing between the center and the wireless subwoofer.There are 2 sources of power board in the   
 center and subwoofer. The two sources of power board are identical with size and function except  
 schematic and PCB layout. 
     Power board of two sources factory: 
     Factory1: Foshan Hanwei  Electron Co., Ltd. 
     Factory2: Shenzhen Jingquanhua (JQH) Electronics Co., Ltd. 
2. The apparatus is intended for indoor use only. 
3.  The max. ambient  temperature is 35°C.  
 
 
 
 
Page 6 of 62 
 
Report No.: 085-120207501-000 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
 
General requirements 
 
Safety class of the apparatus  .................................. :  Class II apparatus. 
 
 
 
 
4 
General test conditions 
4.1.4 
Ventilation instructions require the use of the test 
box  
Yes 
 
 
 
 
5 
Marking and instructions 
 
Comprehensible and easily discernible 
All markings are printed on outer 
enclosures of the appliance. 
 
Permanent durability against water and petroleum 
spirit  
After rubbing test by water and 
petroleum spirit, the markings are 
still easily discernible, indelible 
and legible. 
5.1 
a) Identification, maker  ............................................ :  Trademark and model no. are 
marked on the outer enclosure. 
 
b) Model number or type reference .......................... :  Cinema SB400 
 
c) Class II symbol if applicable  ................................ :  See marking plate 
 
d) Nature of supply .................................................... : 
~
 
 
e) Rated supply voltage  ........................................... :  For center: 100-240V~ 
For subwoofer: 100-240V~ 
 
f) Mains frequency if safety dependant  ................... :  For center: 50/60Hz 
For subwoofer: 50/60Hz 
 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use  ............................................................................ : 
 
N/A 
 
Measured current or power consumption  ............... :   
N/A 
 
Deviation % (max 10%)  ........................................... :   
N/A 
 
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply  : 
For center: 100 W 
For subwoofer: 100 W 
 
Measured current or power consumption  ............... :  (See appended table 7.1) 
 
Measured current or power consumption for 
Television set  ........................................................... : 
 
N/A 
 
Deviation % (max 10%)  ........................................... :  (See appended table 7.1) 
5.2 
a) Earth terminal  
 
N/A 
 
b) Hazardous live terminals  
No such terminals provided. 
N/A 
 
c) Markings on supply output terminals 
No such terminals provided. 
N/A 
5.3 
a) Use of triangle with exclamation mark  
 
 
b) marking on loudspeaker grille, IEC 60417-5036 
 
N/A 
 
 
 
Page 7 of 62 
 
Report No.: 085-120207501-000 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
5.4 
Instructions for use 
English. 
Instruction in other language shall 
be provided when national 
approvals. 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
See user manual. 
 
b) Hazardous live terminals, instructions for wiring   
No such terminals provided 
N/A 
 
c) Instructions for replacing lithium battery  
No batteries provided 
N/A 
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
Not multimedia system. 
N/A 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
No batteries provided 
N/A 
 
h) Warning: protective film on CRT face  
No CRT provided 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
The appliance inlet was used as 
disconnect device. See user 
manual. 
 
c) Instructions for permanently connected equipment   Not permanently connected 
equipment 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
 
 
 
Hazardous radiation 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No ionizing radiation inside the 
EUT. 
N/A 
 
Ionizing radiation under fault condition  
See above. 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ................................................................................... : 
No laser radiation inside the EUT. 
N/A 
 
Emission limits under fault conditions  ..................... :  See above. 
N/A 
 
 
 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table) 
7.1.1 
Temperature rise of accessible parts  
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table) 
7.1.4 
Temperature rise of windings  
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
 
 
Page 8 of 62 
 
Report No.: 085-120207501-000 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
 
N/A 
 
Constructional requirements with regard to the protection against electric shock 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
No such material used 
N/A 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
No cover can be removed. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic material used. 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
No such cover which can be 
removed by hand. 
N/A 
8.5 
Class I equipment  
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
See below. 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Secondary circuit to primary 
circuit is separated by reinforced 
or double insulation. (The 
insulation system of input 
transformer is double insulation 
system). 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
The switching transformer has 
been tested during this approval 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 