Page 21 of 62 
 
Report No.: 085-120207501-000 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
 
N/A 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)  
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
 
N/A 
16.5 
Adequate strain relief on external flexible cords  
 
N/A 
 
Not possible to push cord back into equipment  
 
N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor  
 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use  
 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
 
N/A 
 
 
 
 
17 
Electrical connections and mechanical fixings 
17.1 
Torque test to table 20  
 
 
- screws into metal: 5 times  
 
N/A 
 
- screws into non-metallic material: 10 times  
0.8 Nm for Ø 3.50 mm fixing 
enclosure parts of center 
1.2 Nm for Ø 4.00 mm fixing 
enclosure parts of subwoofer
 
17.2 
Correct introduction into female threads in non-
metallic material  
 
17.3 
Cover fixing screws: captive  
 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
Checked by Ø x 10 screw
 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A  
 
 
 
Page 22 of 62 
 
Report No.: 085-120207501-000 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder  
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
 
17.9 
 
N/A 
 
 
 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
N/A 
18.1 
Picture tube separately approved to IEC 61965  .... : 
No picture tubes used 
N/A 
 
Picture tube separately approved to 18.2  .............. : 
 
N/A 
18.2 
Non-intrinsically protected tubes tested to 18.2 
 
N/A 
 
 
 
 
19 
Stability and mechanical hazards 
 
Mass of the equipment exceeding 7 kg  ................. : 
Measured mass: 3.3 kg for 
center 
Measured mass: 10.9 kg for 
subwoofer
 
N/A 
 
Apparatus intended to be fastened in place 
– 
suitable instructions  ................................................ : 
 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
 
N/A 
19.2 
100 N force applied vertically downwards  
 
N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability  
 
N/A 
19.4 
Edges or corners not hazardous  
Edges or corners are smoothed. 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension 
> 450 mm, pass the test of 19.5.1  
 
N/A 
19.6 
Wall or ceiling mountings adequate  
 
N/A 
 
 
 
 
20 
Resistance to fire 
20.1 
Electrical components and mechanical parts  
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
See sub-clause 20.1.4. 
N/A 
 
b) Exemption for small components as defined in 
20.1  
Small components mounted on a 
PCB with rating as described in 
table 14. Furthermore, refer to 
sub-clause 20.1.4. 
 
 
Page 23 of 62 
 
Report No.: 085-120207501-000 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4  
See sub-clauses 14 and 20.1.4. 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60695-11-10, unless used in a fire 
enclosure  
Flammability of PCB: V-0 or 
better. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60695-11-10.  
 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
(see appended table 14) 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 
N/A 
20.2 
Fire enclosure  
 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
For subwoofer: 
Wooden enclosure thickness 7.0 
mm 
20.2.2 
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
 
 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
N/A 
A.5 
Marking and instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
IP20 
N/A 
A.10 
Insulation requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
 
Page 24 of 62 
 
Report No.: 085-120207501-000 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS 
N/A 
 
Complies with IEC 62151 clause 1  
No TNV 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
 
 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
N/A 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 
60086-4  
 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 
Insulation requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
Page of 127