Page 25 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
7.1 
TABLE: temperature rise measurements:  
 
Power consumption in the OFF mode of the 
functional switch (W)  .............................................. : 
 
 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W)  Uout (V)  Pout (W) 
Operating Condition / Status 
Center with JQH power board 
90 
50 
0.378 
20.4 
3.64 
6.62 
1/8 of max attainable output power with 
standard signal input
 
90 
60 
0.367 
20.5 
3.72 
6.92 
1/8 of max attainable output power with 
standard signal input
 
100 
50 
0.366 
20.3 
3.62 
6.55 
1/8 of max attainable output power with 
standard signal input
 
100 
60 
0.375 
20.5 
3.64 
6.62 
1/8 of max attainable output power with 
standard signal input
 ad 
240 
50 
0.201 
20.3 
3.64 
6.62 
1/8 of max attainable output power with 
standard signal input
 
240 
60 
0.202 
20.3 
3.76 
7.07 
1/8 of max attainable output power with 
standard signal input
 
264 
50 
0.181 
20.3 
3.72 
6.92 
1/8 of max attainable output power with 
standard signal input
 
264 
60 
0.192 
20.5 
3.76 
7.07 
1/8 of max attainable output power with 
standard signal input
 
Subwoofer with JQH power board 
90 
50 
0.469 
23.6 
9.61 
11.54 
1/8 of max attainable output power with 
standard signal input
 
90 
60 
0.476 
24.5 
9.75 
11.88 
1/8 of max attainable output power with 
standard signal input
 
100 
50 
0.440 
24.2 
9.72 
11.81 
1/8 of max attainable output power with 
standard signal input
 
100 
60 
0.430 
23.8 
9.75 
11.88 
1/8 of max attainable output power with 
standard signal input
 ad 
240 
50 
0.250 
26.9 
9.72 
11.81 
1/8 of max attainable output power with 
standard signal input
 
240 
60 
0.266 
26.8 
9.68 
11.71 
1/8 of max attainable output power with 
standard signal input
 
264 
50 
0.228 
27.2 
9.65 
11.64 
1/8 of max attainable output power with 
standard signal input
 
264 
60 
0.253 
28.4 
9.72 
11.81 
1/8 of max attainable output power with 
standard signal input
 
 
Loudspeaker 
impedance (Ω)  .................................. : 
for center: 8,4; for subwoofer: 8 
— 
 
Several loudspeaker systems ................................. : 
for center: 8x4;4x2, for 
subwoofer: 8x1 
— 
 
Marking of loudspeaker terminals ........................... : 
-- 
— 
 
Temperature Rise dT of Part 
 
dT (K) 
Limit max dT 
(K) 
Test Condition No. 
-- 
Center 
Inlet surface (internal) 
10.1 
10.4 
35 
Switch surface (internal) 
9.5 
9.8 
50 
7.2 
7.2 
50 
 
 
Page 26 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
11.3 
10.5 
50 
MOV1 surface 
18.0 
10.6 
50 
CX1 surface 
13.7 
9.0 
75 
LF1 surface 
15.6 
12.3 
85 
LF2 surface 
18.8 
13.8 
85 
CX2 surface 
16.6 
15.2 
75 
PCB surface (under BD1) 
19.6 
12.8 
85 
C1 surface 
20.4 
18.7 
70 
CY1 surface 
15.6 
15.1 
90 
CY2 surface 
18.3 
18.4 
90 
PCB surface (under Q3) 
27.6 
30.7 
85 
PCB surface (under Q4) 
28.5 
31.4 
85 
Primary heat sink surface 
20.4 
23.1 
Ref. 
C20 surface 
26.6 
29.4 
70 
CY3 surface 
22.8 
25.0 
90 
U3 surface 
24.7 
26.8 
65 
T1 winding surface 
28.9 
31.9 
75 
T1 winding surface 
27.3 
30.0 
75 
Core of T1 
28.1 
31.0 
Ref. 
C21 surface 
20.9 
22.8 
70 
C28 surface 
26.2 
30.0 
70 
C5 surface 
23.3 
25.2 
70 
PCB surface (under D12) 
27.8 
30.4 
85 
PCB surface (under Q2) 
15.7 
16.3 
85 
PCB surface (under D11) 
16.7 
17.5 
85 
PCB surface (under D2) 
25.5 
27.9 
85 
Secondary heat sink surface 
19.8 
21.8 
Ref. 
L3 surface 
27.8 
28.6 
85 
10.1 
9.0 
50 
PCB surface (under U501) 
32.7 
33.0 
85 
Enclosure surface (inside) 
13.1 
13.2 
Ref. 
Enclosure surface (outside,Top) 
9.2 
10.2 
60 
Enclosure surface (outside,Side) 
0.8 
0.9 
60 
Enclosure surface (outside,Rear) 
3.5 
3.2 
60 
Button surface 
4.0 
4.1 
50 
Switch surface (outside) 
4.5 
4.7 
50 
Subwoofer: 
Inlet surface (internal) 
3.1 
2.9 
35 
Switch surface (internal) 
8.3 
8.3 
50 
4.0 
3.7 
50 
7.0 
7.3 
50 
MOV1 surface 
15.7 
15.7 
50 
CX1 surface 
13.6 
15.3 
75 
LF1 surface 
11.8 
12.5 
85 
LF2 surface 
14.7 
17.4 
85 
CX2 surface 
10.4 
12.4 
75 
PCB surface (under BD1) 
20.2 
36.6 
85 
 
 
Page 27 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
C38 surface 
15.7 
24.5 
70 
CY1 surface 
10.5 
15.0 
90 
CY2 surface 
12.1 
18.1 
90 
PCB surface (under Q1) 
26.2 
45.3 
85 
Primary heat sink surface 
17.3 
32.7 
Ref. 
CY3 surface 
22.7 
31.3 
90 
U4 surface 
25.0 
33.9 
65 
U3 surface 
20.4 
27.0 
65 
T1 winding surface 
25.2 
30.8 
75 
T1 winding surface 
24 
29.3 
75 
Core of T1 
23.6 
28.8 
Ref. 
T2 winding surface 
23.1 
31.1 
75 
T2 winding surface 
23.5 
31.5 
75 
Core of T2 
23.0 
30.5 
Ref. 
PCB surface (under D3) 
22.2 
28.0 
85 
PCB surface (under D2) 
25.4 
34.9 
85 
C23 surface 
21.5 
28.0 
70 
C14 surface 
17.5 
21.1 
70 
L1 winding surface 
20.1 
24.7 
85 
Secondary heat sink surface 
20.1 
24.3 
Ref. 
6.4 
7.2 
50 
PCB surface (under IC5) 
26.3 
23.9 
85 
Enclosure surface (inside) 
3.4 
9.2 
Ref. 
Enclosure surface (outside,Top) 
2.0 
3.1 
60 
Enclosure surface (outside,Side) 
1.2 
1.1 
60 
Enclosure surface (outside,Rear) 
1.5 
1.5 
60 
Switch surface (outside) 
3.1 
2.9 
50 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C)  ....................... : 
35 
— 
Ambient temperature t2 (
o
C)  ....................... : 
35 
— 
 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) 
– (t2 – t1) 
             R
1
 
R
1
 
(Ω) 
R
2
 
(Ω) 
dT (K) 
Limit max (K)  Insulation class 
-- 
-- 
-- 
-- 
-- 
-- 
Supplementary information:  
1. Test with JQH power board.  
2. Thermocouple method used. 
3. Tma is 35°C Max., the above temp. rise limit are adjusted according to ambient temperature 35°C.  
 
 
 
Page 28 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
7.1 
TABLE: temperature rise measurements:  
 
Power consumption in the OFF mode of the 
functional switch (W)  .............................................. : 
 
 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W)  Uout (V)  Pout (W) 
Operating Condition / Status 
Center with Hanwei power board 
90 
50 
0.447 
20.5 
3.83 
7.33 
1/8 of max attainable output power with 
standard signal input
 
90 
60 
0.416 
20.3 
3.64 
6.62 
1/8 of max attainable output power with 
standard signal input
 
100 
50 
0.365 
20.4 
3.72 
6.92 
1/8 of max attainable output power with 
standard signal input
 
100 
60 
0.338 
20.1 
3.64 
6.62 
1/8 of max attainable output power with 
standard signal input
 ad 
240 
50 
0.171 
20.1 
3.79 
7.18 
1/8 of max attainable output power with 
standard signal input
 
240 
60 
0.201 
20.3 
3.72 
6.92 
1/8 of max attainable output power with 
standard signal input
 
264 
50 
0.169 
20.3 
3.83 
7.33 
1/8 of max attainable output power with 
standard signal input
 
264 
60 
0.191 
20.1 
3.64 
6.62 
1/8 of max attainable output power with 
standard signal input
 
Subwoofer with Hanwei power board 
90 
50 
0.502 
25.3 
10.07 
12.68 
1/8 of max attainable output power with 
standard signal input
 
90 
60 
0.505 
25.7 
10.14 
12.85 
1/8 of max attainable output power with 
standard signal input
 
100 
50 
0.451 
24.9 
9.93 
12.33 
1/8 of max attainable output power with 
standard signal input
 
100 
60 
0.462 
25.5 
10.03 
12.58 
1/8 of max attainable output power with 
standard signal input
 ad 
240 
50 
0.226 
24.0 
9.86 
12.15 
1/8 of max attainable output power with 
standard signal input
 
240 
60 
0.242 
23.1 
9.86 
12.15 
1/8 of max attainable output power with 
standard signal input
 
264 
50 
0.196 
22.5 
9.65 
11.64 
1/8 of max attainable output power with 
standard signal input
 
264 
60 
0.214 
22.4 
9.75 
11.88 
1/8 of max attainable output power with 
standard signal input
 
 
 
Loudspeaker impedance (Ω)  .................................. : 
For center: 8,4; for subwoofer: 
— 
 
Several loudspeaker systems ................................. : 
For center: 8x4,4x2;  for 
subwoofer: 8x1 
— 
 
Marking of loudspeaker terminals ........................... : 
-- 
— 
 
Temperature Rise dT of Part 
 
dT (K) 
Limit max dT 
(K) 
Test Condition No. 
-- 
Center 
Inlet surface (internal) 
15.9 
4.3 
35 
Page of 127