Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
D9 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
TR1 pin1-3 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
TR1 pin5-6 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
10 
TR1 pin7-9 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
11 
TR1 pin10-
11 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
12 
IC3 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
13 
IC3 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
14 
IC3 pin1 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
15 
IC3 pin4 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
16 
Q1 G-D 
S-C 
-- 
F1 opened immediately, F1 broken current: 
8.8A (rated 3.15A), duration: 10 minutes, 
no hazard. 
17 
Q1D-S 
S-C 
-- 
F1 opened immediately, F1 broken current: 
9.1A (rated 3.15A), duration: 10 minutes, 
no hazard. 
18 
Q1 G-S 
S-C 
-- 
Q1 was broken immediately, Input current: 
0.03A, duration: 10 minutes, no hazard. 
19 
C1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
9.5A (rated 3.15A), duration: 10 minutes, 
no hazard. 
20 
D3 
S-C 
-- 
F1 opened immediately, F1 broken current: 
9.3A (rated 3.15A), duration: 10 minutes, 
no hazard. 
21 
VR1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
9.6A (rated 3.15A), duration: 10 minutes, 
no hazard. 
22 
Speaker 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
23 
U501 pin29-
31 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.165A, test duration: 
10 minutes, no hazard.
 
For subwoofer: 
V+&Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
V- &Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.050A, test duration: 
10 minutes, no hazard.
 
 
 
Page 34 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
+3.3V-Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
C27 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.052A, test duration: 
10 minutes, no hazard.
 
D2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
D11 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
C32 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.050A, test duration: 
10 minutes, no hazard.
 
C22 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
D10 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
10 
IC2 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.052A, test duration: 
10 minutes, no hazard.
 
11 
IC2 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
12 
IC2 pin1 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
13 
IC2 pin4 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
14 
IC4 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
15 
IC4 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
16 
IC4 pin1 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
17 
IC4 pin4 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
18 
IC6 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
19 
IC6 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
20 
IC6 pin1 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
21 
IC6 pin4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
 
 
Page 35 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
22 
TR1 pin7-
pin8 
S-C 
-- 
F1 opened immediately, F1 broken current: 
20.3A (rated 5A), duration: 10 minutes, no 
hazard.
 
23 
TR1 pin9-10  S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
24 
TR1 pin2-5 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
25 
TR2 pin1-3 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.052A, test duration: 
10 minutes, no hazard.
 
26 
TR2 pin4-6 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
27 
TR2 pin7-9 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.052A, test duration: 
10 minutes, no hazard.
 
28 
TR2 pin9-11  S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.051A, test duration: 
10 minutes, no hazard.
 
29 
Q1 G-D 
S-C 
-- 
Q1,D3,D2  was broken immediately, Input 
current: 0A, duration: 10 minutes, no 
hazard. 
30 
Q1 D-S 
S-C 
-- 
Q1, D1 was broken immediately, Input 
current: 0A, duration: 10 minutes, no 
hazard. 
31 
D16 
S-C 
-- 
Similar with normal operation, no hazard. 
32 
IC5 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.052A, test duration: 
10 minutes, no hazard.
 
33 
IC1 pin2-5 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard. 
34 
C1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
23.7A (rated 5A), duration: 10 minutes, no 
hazard.
 
35 
D1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
22.5A (rated 5A), duration: 10 minutes, no 
hazard.
 
36 
VR1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
25.0A (rated 5A), duration: 10 minutes, no 
hazard.
 
37 
Speaker 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
38 
IC5 pin3-16 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.053A, test duration: 
10 minutes, no hazard.
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  .................................. :  -- 
— 
 
Ambient temperature t2 (
o
C)  .................................. :  -- 
— 
 
 
Page 36 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
Remark: 
1. 
―S-C‖ means short-circuited test, ―O-L‖ means overload test, ―O-C‖ means open-circuited test. 
2. Thermocouple method used for all points. 
3. Tma is 35°C Max., the above temp. rise limit are adjusted according to ambient temperature 35°C. 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  .......... :  264 
— 
 
Frequency (Hz ...................................................... :  50 
— 
 
Ambient temperature (
o
C)  ................................... :  20-25 
— 
 
No 
Component 
Fault 
dT (K) / Component 
Other results 
(include description and test duration) 
With JQH power board: 
100% max 
non-clipped 
output power 
-- 
For center: 
LF1 surface: 30.1K 
LF2 surface: 34.3K 
T1 winding : 79.4K 
PCB surface (under 
Q3): 74.2K 
PCB surface (under 
U501): 69.3K 
Enclosure surface 
(outside,Top): 23.5K 
For subwoofer: 
LF1 surface: 56.7.1K 
LF2 surface: 72.9K 
T1 winding : 73.5K 
T2 winding : 55.3K 
PCB surface (under 
Q1): 83.4K 
PCB surface (under 
IC5): 69.9K 
Enclosure surface 
(outside,rear): 4.2K 
Input current: 0.675 A for center, 0.94 A for 
subwoofer; 
No Hazard, the apparatus 
operated until steady status.
 duration: 6 
hours, no hazard. 
For center: 
Block 
ventilation 
-- 
-- 
Similar with normal operation, duration: 3 
hours 23 minutes, no hazard. 
BK5.0V-Gnd  S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.028A, test duration: 
10 minutes, no hazard.
 
+5.0V-Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.028A, test duration: 
10 minutes, no hazard.
 
+18V-Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.03A, test duration: 10 
minutes, no hazard.
 
Page of 127
Display

Click on the first or last page to see other SB 400 (serv.man4) service manuals if exist.