Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
D2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.048A, test duration: 
10 minutes, no hazard.
 
D11 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.048A, test duration: 
10 minutes, no hazard.
 
D12 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.048A, test duration: 
10 minutes, no hazard.
 
Q2 C-E 
S-C 
-- 
Similar with normal operation, no hazard.
 
10 
Q5 G-D 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.048A, test duration: 
10 minutes, no hazard.
 
11 
Q5 S-D 
S-C 
-- 
Similar with normal operation, no hazard.
 
12 
T1 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
13 
T1 pin4-6 
S-C 
-- 
Q3 was broken immediately, Input current: 
0A, duration: 10 minutes, no hazard. 
14 
T1 pin7-8 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
15 
T1 pin11-12  S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
16 
U3 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
17 
U3 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.042A, test duration: 
10 minutes, no hazard.
 
18 
U3 pin1 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
19 
U3 pin4 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
20 
Q3 G-D 
S-C 
-- 
Q3 was broken immediately, Input current: 
0A, duration: 10 minutes, no hazard. 
21 
Q3 D-S 
S-C 
-- 
Q3 was broken immediately, Input current: 
0A, duration: 10 minutes, no hazard. 
22 
Q3 G-S 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
23 
Q4 C-E 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
24 
U1 Vcc-gate  S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
25 
D10 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
26 
D1 
S-C 
-- 
Q3 was broken immediately, Input current: 
0A, duration: 10 minutes, no hazard. 
 
 
Page 38 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
27 
C1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
9.8 A (rated 3.15A), duration: 10 minutes, 
no hazard.
 
28 
BD1 +,~ 
S-C 
-- 
F1 opened immediately, F1 broken current: 
9.0A  (rated  3.15A),  duration:  10  minutes, 
no hazard.
 
29 
MOV1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
9.2A (rated 3.15A), duration: 10 minutes, 
no hazard.
 
30 
Speaker 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.147A, test duration: 
10 minutes, no hazard. 
31 
U501 pin29-
31 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.165A, test duration: 
10 minutes, no hazard. 
For subwoofer: 
+24V-Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
-24V-Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
+3.3-Gnd 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
C13 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
D2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.043A, test duration: 
10 minutes, no hazard.
 
U7 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.043A, test duration: 
10 minutes, no hazard.
 
C18 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
D9 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
U8 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.043A, test duration: 
10 minutes, no hazard.
 
10 
U2 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
11 
U2 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
12 
U2 pin1 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
13 
U2 pin4 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
 
 
Page 39 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
14 
U3 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
15 
U3 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
16 
U3 pin1 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
17 
U3 pin4 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
18 
U4 pin1-2 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.040A, test duration: 
10 minutes, no hazard.
 
19 
U4 pin3-4 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.044A, test duration: 
10 minutes, no hazard.
 
20 
U4 pin1 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
21 
U4 pin4 
O-C 
-- 
The apparatus was protected, the input 
current dropped to 0.04A, test duration: 10 
minutes, no hazard.
 
22 
T1 pin1,2-
4,5 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.044A, test duration: 
10 minutes, no hazard. 
23 
T1 pin13-11  S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
24 
T1 pin11-pin 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.042A, test duration: 
10 minutes, no hazard.
 
25 
T2 pin5-7 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
26 
T2 pin9-10 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.043A, test duration: 
10 minutes, no hazard.
 
27 
T2 pinA-pinB  S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.041A, test duration: 
10 minutes, no hazard.
 
28 
U6 pin1-3 
S-C 
-- 
Q1, R30 was broken immediately, Input 
current: 0A, duration: 10 minutes, no 
hazard. 
29 
Q1 G-D 
S-C 
-- 
Q1,R39,R29,BD1was broken immediately, 
Input current: 0A, duration: 10 minutes, no 
hazard. 
30 
Q1 D-S 
S-C 
-- 
Q1, R30, BD1 was broken immediately, 
Input current: 0A, duration: 10 minutes, no 
hazard. 
31 
U1 pin1-7 
S-C 
-- 
Similar with normal operation, no hazard. 
32 
D1 
S-C 
-- 
Q1 was broken immediately, Input current: 
0A, duration: 10 minutes, no hazard. 
33 
C38 
S-C 
-- 
F1 opened immediately, F1 broken current: 
22.8A (rated 6.3A), duration: 10 minutes, 
no hazard.
 
 
 
Page 40 of 62 
Report No.: 085-120207501-000
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict
 
 
TRF No. IEC60065K                                                                                               Jiangsu TÜV Product Service Ltd. Guangzhou Branch 
34 
BD1 +,~ 
S-C 
-- 
F1 opened immediately, F1 broken current: 
25.4A (rated 6.3A), duration: 10 minutes, 
no hazard.
 
35 
MOV1 
S-C 
-- 
F1 opened immediately, F1 broken current: 
23.3A (rated 6.3A), duration: 10 minutes, 
no hazard.
 
36 
Speaker 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.134A, test duration: 
10 minutes, no hazard. 
37 
IC5 pin3-16 
S-C 
-- 
The apparatus was protected, the input 
current dropped to 0.043A, test duration: 
10 minutes, no hazard.
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  .................................. :  -- 
— 
 
Ambient temperature t2 (
o
C)  .................................. :  -- 
— 
Remark: 
1. 
―S-C‖ means short-circuited test, ―O-L‖ means overload test, ―O-C‖ means open-circuited test. 
2. Thermocouple method used for all points. 
3. Tma is 35°C Max., the above temp. rise limit are adjusted according to ambient temperature 35°C. 
 
13.2 
TABLE: Determination of operating voltage 
P        
Location 
RMS Voltage (V) 
Peak Voltage 
(V) 
Comments 
For Center with hanwei power board: 
TR1 pin 2 
– pin 7,8 
234 
364 
 
TR1 pin 2 
– pin 9,10 
234 
432 
 
TR1 pin 2 
– pin 11 
234 
380 
 
TR1 pin 2 
– pin 12 
233 
364 
 
TR1 pin 3 
– pin 7,8 
243 
456 
Max. Vrms, Max. Vpeak 
TR1 pin 3 
– pin 9,10 
238 
436 
 
TR1 pin 3 
– pin 11 
242 
448 
 
TR1 pin 3 
– pin 12 
242 
448 
 
TR1 pin 5 
– pin 7,8 
202 
386 
 
TR1 pin 5 
– pin 9,10 
200 
324 
 
TR1 pin 5 
– pin 11 
202 
356 
 
TR1 pin 5 
– pin 12 
202 
376 
 
TR1 pin 6 
– pin 7,8 
202 
324 
 
TR1 pin 6 
– pin 9,10 
201 
340 
 
TR1 pin 6 
– pin 11 
202 
328 
 
TR1 pin 6 
– pin 12 
202 
324 
 