JBL SB 200 (serv.man6) EMC - CB Certificate ▷ View online
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 5 of 59
1. TEST RESULT SUMMARY
EN 301 489-17 V2.1.1 (2009-05) &EN 301 489-1 V1.8.1(2008-04)
Standard
Item
Result
Remarks
EN 301 489-17 V2.1.1
(2009-05) &EN 301
489-1 V1.8.1(2008-04)
Conducted Emission
PASS
Meets the Class B requirement
Radiated Emission
PASS
Meets the Class B requirement
Harmonics Current
N/A
Less than 75w
Voltage Fluctuation
and Flicks
PASS
/
EN 301 489-17 V2.1.1 (2009-05) &EN 301 489-1 V1.8.1(2008-04)
Standard
Item
Result
Remarks
EN 61000-4-2:2008
ESD
PASS
Meets the requirements of
Performance Criterion B
EN 61000-4-3: 2006 +
A1: 2007 + A2: 2010
RS PASS
Meets the requirements of
Performance Criterion A
EN 61000-4-4:2004 +
A1: 2010
EFT PASS
Meets the requirements of
Performance Criterion B
EN 61000-4-5:2005
Surge
PASS
Meets the requirements of
Performance Criterion B
EN 61000-4-6:2008
CS
PASS
Meets the requirements of
Performance Criterion A
EN 61000-4-11:2004
Voltage Dips & Short
Interruptions
PASS
Meets the requirements of
Performance Criterion B and C
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 6 of 59
2. GENERAL DESCRIPTION OF EUT
2.1 Applicant
Name:
Harman International Industries, Inc.
Address:
2.2 Manufacturer
Name:
Harman International Industries, Inc.
Address:
2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST
Equipment: Soundbar
Model No.: CINEMA SB200
Trade
Name:
Name:
Harman
Power:
100-240V 50/60Hz 60W
Type of
modulation
modulation
GFSK, 8DPSK, Pi/4 QPSK
Operating
Frequency:
Frequency:
2402MHz~2480MHz
Channels:
Channels with 1MHz step
Antenna
Type
Integral
Test mode
1、 Optical fiber mode
2、 AUX IN
3、 BT
2、 AUX IN
3、 BT
Note:
The EUT have no any interface for other device. During test do not need to add any other load.
On the testing situation, control the power with operation volume of product .
On the testing situation, control the power with operation volume of product .
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 7 of 59
3. LABORATORY AND ACCREDITATIONS
3.1 LABORATORY
The tests and measurements refer to this report were performed by EMC Laboratory of Guangzhou
GRG Metrology and Test CO., LTD.
Add.
: 163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China
Telephone: +86-20-38699959, 38699960, 38699961
Fax
: +86-20-38695185
3.2 ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies according to
ISO/IEC 17025.
ISO/IEC 17025.
USA
FCC Listed Lab No. 688188
China
CNAS NO.L0446
China
DILAC No.DL175
Canada
Registration No.:8355A-1
3.3 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the EUT as specified in CISPR 16-4-2:
Measurement
Frequency
Uncertainty
Radiated
Emission
Emission
Horizontal 30MHz~1000MHz 4.2dB
Horizontal 1GHz~6GHz 4.2dB
Vertical 30MHz~1000MHz 4.4dB
Vertical 1GHz~6GHz 4.4dB
Horizontal 1GHz~6GHz 4.2dB
Vertical 30MHz~1000MHz 4.4dB
Vertical 1GHz~6GHz 4.4dB
Conducted Emission
9kHz~30MHz 3.1
dB
This uncertainty represents an expanded uncertainty factor of
k=2.
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 8 of 59
3.4 TEST INSTRUMENTS
Name of equipment
Manufacturer
Model
Serial number Calibration due
RE
Biconical
Log-periodic Antenna
ETS.LINDGREN
3142C 00075971
2014-05-26
Receiver R&S
ESU40
100106
2013-02-04
Horn antenna
SCHWARZBECK
BBHA9120D
D752
2013-10-14
CE
EMI Receiver
R&S
ESCI
100529
2012-08-16
L.I.S.N SCHWARZBECK
NSLK
8127
8127450 2012-08-21
ISN TESEQ
ISN-T8
24821
2013-06-08
EMI Receiver
R&S
ESCS30
100317
2013-08-24
Harmonics & Flicker
AC Source
California
Instruments
5001ix-400-LF
57549 2013-07-05
Power Analyzer
California
Instruments
PACS-1 72501 2013-07-05
ESD
ESD Tester
EMPEK
ESD-2030A
0230809N
2012-08-21
RS
Signal generator
Rohde & Schwarz
SML03
103002
2012-11-14
Power meter
BOOTON
4232A
10543
2012-09-26
Amplifier
PRANA R&D
AP32 DT214
0611-768
2013-01-03
Amplifier
PRANA R&D
AP32 SV150A
0611-767
2013-01-03
Log-periodic Antenna SCHWARZBECK
STLP 9128 E
9128E-029
2014-05-26
Horn Antenna
SCHWARZBECK
BBHA 9120E
BBHA9120E31
8
2013-10-14
EFT
EFT Generator
EMC PARTNER
TRA2000
853
2013-03-06
EFT Coupling Clamp EMC PARTNER
CN-EFT1000
521
2013-03-06
Surge
Surge Generator
EMC PARTNER
TRA2000
852
2013-05-31
CDN EMC
PARTNER
CDN
2000-06-32
110 2013-05-29
Transient Immunity
Test System
EMC PARTNER
‐
TRANSIENT20
00
845
2013-07-13
Click on the first or last page to see other SB 200 (serv.man6) service manuals if exist.