Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 5 of 59 
 
1. TEST RESULT SUMMARY  
EN 301 489-17 V2.1.1 (2009-05) &EN 301 489-1 V1.8.1(2008-04) 
Standard 
Item 
Result
Remarks 
EN 301 489-17 V2.1.1 
(2009-05) &EN 301 
489-1 V1.8.1(2008-04) 
Conducted Emission 
PASS
Meets the Class B requirement 
Radiated Emission 
PASS
Meets the Class B requirement  
Harmonics Current 
N/A 
Less than 75w 
Voltage Fluctuation 
and Flicks 
PASS
 
 
EN 301 489-17 V2.1.1 (2009-05) &EN 301 489-1 V1.8.1(2008-04) 
Standard 
Item 
Result
Remarks 
EN 61000-4-2:2008 
ESD 
PASS
Meets the requirements of 
Performance Criterion B 
    EN 61000-4-3: 2006 + 
A1: 2007 + A2: 2010 
RS PASS
Meets the requirements of 
Performance Criterion A 
EN 61000-4-4:2004 + 
A1: 2010 
EFT PASS
Meets the requirements of 
Performance Criterion B 
EN 61000-4-5:2005 
Surge 
PASS
Meets the requirements of 
Performance Criterion B 
EN 61000-4-6:2008 
CS 
PASS
Meets the requirements of 
Performance Criterion A 
EN 61000-4-11:2004 
Voltage Dips & Short 
Interruptions 
PASS
Meets the requirements of 
Performance Criterion B and C 
 
 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 6 of 59 
 
2. GENERAL DESCRIPTION OF EUT 
2.1 Applicant 
Name: 
Harman International Industries, Inc.
 
Address: 
2.2 Manufacturer 
Name: 
Harman International Industries, Inc.
 
Address: 
2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST  
Equipment:  Soundbar
 
Model No.:  CINEMA SB200
 
Trade 
Name: 
Harman
 
Power: 
100-240V 50/60Hz  60W 
Type of 
modulation 
GFSK, 8DPSK, Pi/4 QPSK 
Operating 
Frequency: 
2402MHz~2480MHz 
Channels: 
Channels with 1MHz step 
Antenna 
Type 
Integral 
Test mode 
1、 Optical fiber mode 
2、 AUX IN 
3、 BT 
Note: 
The  EUT  have  no any  interface  for other  device. During  test do not  need  to add  any other  load.
On  the  testing  situation, control  the  power  with  operation  volume  of  product .  
 
 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 7 of 59 
 
 
3. LABORATORY AND ACCREDITATIONS  
3.1 LABORATORY 
The tests and measurements refer to this report were performed by EMC Laboratory of Guangzhou 
GRG Metrology and Test CO., LTD. 
         Add. 
  :    163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China 
         Telephone:   +86-20-38699959, 38699960, 38699961 
Fax 
  :   +86-20-38695185 
3.2 ACCREDITATIONS 
Our laboratories are accredited and approved by the following approval agencies according to 
ISO/IEC 17025. 
 
USA 
FCC Listed Lab No. 688188 
China 
CNAS NO.L0446 
China 
DILAC No.DL175 
Canada 
Registration No.:8355A-1 
 
3.3 MEASUREMENT UNCERTAINTY 
Where relevant, the following measurement uncertainty levels have been estimated for tests 
performed on the EUT as specified in CISPR 16-4-2: 
Measurement 
Frequency 
Uncertainty 
Radiated 
Emission 
Horizontal 30MHz~1000MHz 4.2dB 
Horizontal 1GHz~6GHz 4.2dB 
Vertical 30MHz~1000MHz 4.4dB 
Vertical 1GHz~6GHz 4.4dB 
Conducted Emission 
9kHz~30MHz 3.1 
dB 
This uncertainty represents an expanded uncertainty factor of
 
k=2. 
 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 8 of 59 
 
3.4 TEST INSTRUMENTS 
 
Name of equipment 
Manufacturer 
Model 
Serial number  Calibration due
RE 
Biconical 
Log-periodic Antenna
ETS.LINDGREN
3142C 00075971 
2014-05-26 
Receiver R&S 
ESU40 
100106 
2013-02-04 
Horn antenna 
SCHWARZBECK
BBHA9120D 
D752 
2013-10-14 
CE 
EMI Receiver 
R&S 
ESCI 
100529 
2012-08-16 
L.I.S.N SCHWARZBECK
NSLK 
8127 
8127450 2012-08-21 
ISN TESEQ 
ISN-T8 
24821 
2013-06-08 
EMI Receiver 
R&S 
ESCS30 
100317 
2013-08-24 
Harmonics & Flicker 
AC Source 
California 
Instruments 
5001ix-400-LF
57549 2013-07-05
 
Power Analyzer 
California 
Instruments 
PACS-1 72501 2013-07-05
 
ESD 
ESD Tester 
EMPEK 
ESD-2030A 
0230809N 
2012-08-21 
RS 
Signal generator 
Rohde & Schwarz
SML03 
103002 
2012-11-14
 
Power meter 
BOOTON 
4232A 
10543 
2012-09-26
 
Amplifier 
PRANA R&D 
AP32 DT214 
0611-768 
2013-01-03
 
Amplifier 
PRANA R&D 
AP32 SV150A
0611-767 
2013-01-03
 
Log-periodic Antenna SCHWARZBECK
STLP 9128 E 
9128E-029 
2014-05-26
 
Horn Antenna 
SCHWARZBECK
BBHA 9120E
BBHA9120E31
2013-10-14
 
EFT 
EFT Generator 
EMC PARTNER
TRA2000 
853 
2013-03-06
 
EFT Coupling Clamp EMC PARTNER
CN-EFT1000 
521 
2013-03-06
 
Surge 
Surge Generator 
EMC PARTNER
TRA2000 
852 
2013-05-31
 
CDN EMC 
PARTNER
CDN 
2000-06-32 
110 2013-05-29
 
Transient  Immunity  
Test System  
EMC PARTNER
 
 
TRANSIENT20
00
 
845 
 
2013-07-13 
 
Page of 59