Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 25 of 59 
 
 
Project No.: 
ZJ00016958 
Probe: 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2012-7-24 
Temp./Hum.(%RH): 22/46%RH 
Time: 
16:25:06 
EUT: Soundbar 
 
 
Model: 
CINEMA SB200 
Test Result: 
Pass 
Note:  
Optical fiber mode 
 
keep the  product  on  the  full  volume to make sure  the  power  is  maximum 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.1615 33.21 11.79 45.00 
65.38 
-20.38 
QP 
2 0.1615 18.41 11.79 30.20 
55.38 
-25.18  AVG 
3 0.1932 30.98 11.22 42.20 
63.89 
-21.69 
QP 
4 0.1932 16.98 11.22 28.20 
53.89 
-25.69  AVG 
5 0.5493 23.78 10.52 34.30 
56.00 
-21.70 
QP 
6 0.5493 15.78 10.52 26.30 
46.00 
-19.70  AVG 
7 1.2555 19.67 10.53 30.20 
56.00 
-25.80 
QP 
8 1.2555 13.67 10.53 24.20 
46.00 
-21.80  AVG 
9 3.8603 21.68 10.62 32.30 
56.00 
-23.70 
QP 
10 3.8603 14.38 10.62 25.00 46.00 -21.00 
AVG 
11 4.8224 23.59 10.71 34.30 56.00 -21.70 
QP 
12 4.8224 17.19 10.71 27.90 46.00 -18.10 
AVG 
 
 
 
 
 
 
 
 
 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 26 of 59 
 
4.3 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 
4.3.1 LIMITS 
Test standard: EN 61000-3-3:2008 
Test Item 
Limit 
Remark 
P
st
 1.0 
P
st 
means short-term flicker indicator. 
P
lt
 0.65 
P
lt
 means long-term flicker indicator. 
T
dt
 (ms) 
500 
T
dt 
means maximum time that dt exceeds 3 %. 
d
max
 (%) 
4% 
d
max
 means maximum relative voltage change. 
dc (%) 
3.3% 
dc means relative steady-state voltage change 
4.3.2 TEST PROCEDURES 
The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated 
to produce the most unfavorable sequence of voltage changes under normal operating 
conditions. 
During the flick measurement, the measure time shall include that part of whole operation 
cycle in which the EUT produce the most unfavorable sequence of voltage changes. The 
observation period for short-term flicker indicator is 10 minutes and the observation period 
for long-term flicker indicator is 2 hours. 
4.3.3 TEST SETUP 
 
 
Harmonics & 
Flicker 
Analyzer 
Power Source 
 
EUT 
 
Support  
Power 
Cord
 
0.8
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 27 of 59 
 
4.3.4 TEST RESULTS 
Flicker Test Summary per EN/IEC61000-3-3  (Run time) 
 
EUT: SOUNDBAR 
Tested by: LIANG 
Start time: 10:02:00 
End time: 10:12:21 
Test duration (min): 10  Data file name: F-000084.cts_data 
Comment: keep the  product  on  the  full  volume to make sure  the  power  is  maximum. 
Customer: Customer information 
 
Test Result: Pass 
Status: Test Completed 
 
 
Pst
i
Limits 
 
Plt and limit line  
 
Parameter values recorded during the test: 
Vrms at the end of test (Volt): 
230.06 
Highest dt (%):  0.74 
Test limit (%):                                                 3.30  Pass 
Time(mS) > dt:   0.0 
Test limit (mS):                       500.0 
Pass 
Highest dc (%):  0.00 
Test limit (%):                                    3.30  Pass 
Highest dmax (%): 
-0.81 
Test limit (%):                                   4.00  Pass 
Highest Pst (10 min. period):         0.083  Test limit:                1.000 Pass  
 
Highest Plt (2 hr. period):               0.036  Test limit:                0.650 Pass 
 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 28 of 59 
 
5. IMMUNITY TEST 
5.1 GENERAL DESCRIPTION 
Product Standard 
ETSI EN 301 489-17 V2.1.1 (2009-05) & EN 301 489-1 V1.8.1(2008-04) 
Test set-up 
Test specification 
ETSI EN 301 489-17 
V2.1.1  & EN 301 
489-1 V1.9.2 
 
EN 61000-4-2 
Electrostatic Discharge – ESD: 
8kV air discharge, 4kV Contact discharge 
Performance Criterion B 
EN 61000-4-3 
Radio-Frequency Electromagnetic Field Susceptibility 
Test – RS: 
80 ~1000 MHz, 1400~2700 MHz 3V/m, 80% 
AM(1kHz),  
Performance Criterion A 
EN 61000-4-4 
Electrical Fast Transient/Burst - EFT, 
AC power Port: 1kV,  
DC power Port: 0.5kV 
Signal and control line: 0.5kV, 
Performance Criterion B 
EN 61000-4-5 
Surge Immunity Test: 
1.2/50 us Open Circuit Voltage, 
8 /20 us Short Circuit Current, 
AC Power Port: line to earth: ±1kV, line to line: ±0.5kV
Performance Criterion B 
EN 61000-4-6 
Conducted Radio Frequency Disturbances Test –CS: 
0.15 ~ 80 MHz, 3Vrms, 80% AM, 1kHz, 
Performance Criterion A 
EN 61000-4-11 
Voltage dips: 
30 during 25 periods, 
Meets the requirements of  Performance Criterion C
Voltage interruption: 
100% during 0.5 cycles, 
100% during 1 cycles, 
Meets the requirements of Performance Criterion B 
100% during 250 cycles, 
Meets the requirements of Performance Criterion C 
 
 
 
 