JBL SB 200 (serv.man6) EMC - CB Certificate ▷ View online
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 17 of 59
Project No.:
ZJ00016958
Polarziation:
Vertical
Standard:
(RE)EN55022_class B_3m
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2012-7-24
Temp./Hum.(%RH): 23/50%RH
Time:
15:39:47
EUT: Soundbar
Distance:
3m
Model:
CINEMA SB200
Test Result:
Pass
Note:
BT
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1 34.7196 17.24 16.56 33.80 40.00 -6.20
QP
2 91.2728 23.04 9.66 32.70 40.00 -7.30
QP
3 125.7335 16.06 8.74 24.80 40.00 -15.20
QP
4 147.1586 13.74 9.86 23.60 40.00 -16.40
QP
Note: Above 1GHz, since the radiated emission of the EUT is too weak to be detected.
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 18 of 59
4.2 CONDUCTED EMISSION MEASUREMENT
4.2.1 LIMITS
AC Power port
Frequency (MHz)
Quasi-peak(dBµV)
Average(dBµV)
0.15 ~ 0.5
66~56 56~46
0.5 ~ 5
56 46
5 ~ 30
60
50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 ~0.5 MHz.
Telecommunication ports
Frequency (MHz)
Quasi-peak(dBµV)
Average(dBµV)
0.15 ~ 0.5
84~74 74~64
0.5 ~ 30
74 64
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 ~0.5 MHz.
Telecommunication ports
4.2.2 TEST PROCEDURES
Procedure of Preliminary Test
For measurement of the disturbance voltage the equipment under test (EUT) is connected to
the power supply mains and any other extended network via one or more artificial network(s).
An EUT, whether intended to be grounded or not, and which is to be used on a table is
configured as follows:
the power supply mains and any other extended network via one or more artificial network(s).
An EUT, whether intended to be grounded or not, and which is to be used on a table is
configured as follows:
– Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as
follows:
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as
follows:
1) place the EUT on a table of non-conducting material which is at least 80 cm high. Place the
EUT so that it is 40 cm from the wall of the shielded room, or
EUT so that it is 40 cm from the wall of the shielded room, or
2) place the EUT on a table of non-conducting material which is 40 cm high so that the
bottom of the EUT is 40 cm above the ground plane;
bottom of the EUT is 40 cm above the ground plane;
– All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground
plane;
plane;
– The ANs are placed on the floor that one side of the AN housings is 40 cm from the
vertical reference ground plane and other metallic parts;
vertical reference ground plane and other metallic parts;
– Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle
between the ground plane and the table.
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle
between the ground plane and the table.
– I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the
cable may be terminated if required using correct terminating impedance. The total length
shall not exceed 1 m.
The test mode(s) described in Item 2.3 were scanned during the preliminary test. After the
preliminary scan, we found the test mode described in Item 2.3 producing the highest
cable may be terminated if required using correct terminating impedance. The total length
shall not exceed 1 m.
The test mode(s) described in Item 2.3 were scanned during the preliminary test. After the
preliminary scan, we found the test mode described in Item 2.3 producing the highest
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 19 of 59
emission level. The EUT configuration and cable configuration of the above highest emission
levels were recorded for reference of the final test.
levels were recorded for reference of the final test.
Procedure of Final Test
EUT and support equipment were set up on the test bench as per the configuration with
highest emission level in the preliminary test.Emission frequency and amplitude were
recorded into a computer in which correction factors were used to calculate the emission level
and compare reading to the applicable limit. The test data of the worst-case condition(s) was
recorded.
highest emission level in the preliminary test.Emission frequency and amplitude were
recorded into a computer in which correction factors were used to calculate the emission level
and compare reading to the applicable limit. The test data of the worst-case condition(s) was
recorded.
4.2.3 TEST SETUP
Report No.: EM201200331-2 Application No.: ZJ00016958 Page 20 of 59
4.2.4 TEST RESULTS
Project No.:
ZJ00016958
Probe:
L1
Standard:
(CE)EN55022 class B_QP
Power Source:
AC 230V/50Hz
Test item:
Conduction Test
Date:
2012-7-24
Temp./Hum.(%RH): 22/46%RH
Time:
16:26:51
EUT: Soundbar
Model:
CINEMA SB200
Test Result:
Pass
Note:
BT
keep the product on the full volume to make sure the power is maximum
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV)
Factor(dB)
(dBuV)
(dBuV)
(dB)
1 0.1615 33.51 11.79 45.30
65.38
-20.08
QP
2 0.1615 18.81 11.79 30.60
55.38
-24.78 AVG
3 0.1932 29.18 11.22 40.40
63.89
-23.49
QP
4 0.1932 17.38 11.22 28.60
53.89
-25.29 AVG
5 0.2255 27.03 10.97 38.00
62.61
-24.61
QP
6 0.2255 15.73 10.97 26.70
52.61
-25.91 AVG
7 0.5493 19.68 10.52 30.20
56.00
-25.80
QP
8 0.5493 24.58 10.52 35.10
56.00
-20.90
QP
9 5.5053 22.41 10.79 33.20
60.00
-26.80
QP
10 5.5053 16.31 10.79 27.10 50.00 -22.90
AVG
11 6.4537 23.89 10.71 34.60 60.00 -25.40
QP
12 6.4537 17.09 10.71 27.80 50.00 -22.20
AVG