Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 29 of 59 
 
5.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION 
Criteria A 
The apparatus shall continue to operate as intended during the test. No 
degradation of performance or loss of function is allowed below a performance 
level (or permissible loss of performance) specified by the manufacturer, when 
the apparatus is used as intended. If the minimum performance level or the 
permissible performance loss is not specified by the manufacturer, then either of 
these may be derived from the product description and documentation, and from 
what the user may reasonably expect from the apparatus if used as intended. 
Criteria B 
The apparatus shall continue to operate as intended after the test. No degradation 
of performance or loss of function is allowed below a performance level (or 
permissible loss of performance) specified by the manufacturer, when the 
apparatus is used as intended. During the test, degradation of performance is 
allowed, however, no change of actual operating state or stored data is allowed. If 
the minimum performance level or the permissible performance loss is not 
specified by the manufacturer, then either of these may be derived from the 
product description and documentation, and from what the user may reasonably 
expect from the apparatus if used as intended. 
Criteria C 
 Temporary loss of function is allowed, provided the function is self- recoverable 
or can be restored by the operation of the controls, or by any operation specified in 
the instructions for use. Not all functions of the apparatus need to be tested. The 
selection, the specification of functions, and the permissible degradation is left to 
the responsibility of the manufacturer. 
 
 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 30 of 59 
 
5.3 ELECTROSTATIC DISCHARGE (ESD) 
5.3.1 TEST SPECIFICATION 
Basic Standard 
IEC 61000-4-2:
 
2008 
Discharge Impedance 
330 ohm / 150 pF 
Discharge Voltage 
Air Discharge       : ±8 kV; 
Contact Discharge: ± 4 kV  
Polarity 
Positive & Negative 
Number of Discharge 
Minimum 10 times at each test point 
Discharge Mode 
Single Discharge 
1 second minimum 
5.3.2 TEST PROCEDURE  
The basic test procedure was in accordance with IEC 61000-4-2: 
a) The EUT was located 0.1 m minimum from all side of the HCP (dimensions 1.6m * 0.8m). 
b) The support units were located another table 30 cm away from the EUT, but direct support unit 
was/were located at same location as EUT on the HCP and keep at a distance of 10 cm with EUT. 
c) The time interval between two successive single discharges was at least 1 second. 
d) Contact discharges were applied to the non-insulating coating, with the pointed tip of the generator 
penetrating the coating and contacting the conducting substrate. 
e) Air discharges were applied with the round discharge tip of the discharge electrode approaching the 
EUT as fast as possible (without causing mechanical damage) to touch the EUT. After each 
discharge, the ESD generator was removed from the EUT and re-triggered for a new single 
discharge. The test was repeated until all discharges were complete. 
f) At least ten single discharges (in the most sensitive polarity) were applied at the front edge of each 
HCP opposite the center point of each unit of the EUT and 0.1 meters from the front of the EUT. 
The long axis of the discharge electrode was in the plane of the HCP and perpendicular to its front 
edge during the discharge. 
g) At least ten single discharges (in the most sensitive polarity) were applied to the center of one 
vertical edge of the Vertical Coupling Plane (VCP) in sufficiently different positions that the four 
faces of the EUT were completely illuminated. The VCP  (dimensions 0.5m * 0.5m) was placed 
vertically to and 0.1 meters from the EUT. 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 31 of 59 
 
5.3.3 TEST SETUP 
 
 
 
Report No.:  EM201200331-2               Application No.:  ZJ00016958                                 Page 32 of 59 
 
 
5.3.4 TEST RESULTS 
EUT 
Soundbar 
Mode Number 
CINEMA SB200 
Test date 
2012-07-23 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
David Li 
environment 
Tem:25 Hum:58 %100kPa 
Test mode: 
1. Optical fiber mode
 
2. AUX IN 
3. BT 
 
 
Discharge point 
Discharge 
voltage 
C-Conduct 
A-Air 
Required Passing 
Performance 
Actual 
performance 
Result 
Nonmetallic 
exposed surface & 
button 
±8  kV 
Criterion B 
Criterion A* 
PASS 
Vertical coupling 
plane 
±4  kV 
Criterion B 
Criterion A* 
PASS 
Horizontal coupling 
plane 
±4  kV 
Criterion B 
Criterion A* 
PASS 
*: There was no change compared with the initial operation during the test. 
 
 