- Page 4 of 8 - 
 
 
www.nemko.com 
Report No.   241619 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
2.6.5.4 
Replace 1st sentence with the following.  
Protective earthing connections of CLASS I 
EQUIPMENT shall make earlier and break later 
than the supply connections in each of the 
following: 
Class III equipment. 
N/A 
2.6.5.8A 
Add the following new clause. after 2.6.5.8A  
 2.6.5.8A Earthing of CLASS 0I EQUIPMENT Plugs 
with a lead wire for earthing shall not be used for 
equipment having a rated voltage exceeding 150V. 
For plugs with a lead wire for earthing, the lead 
wire shall not be earthed by a clip.  
CLASS 0I EQUIPMENT shall be provided with an 
earthing terminal or lead wire for earthing in the 
external location where easily visible. 
Class III equipment. 
N/A 
3.2.3 
Add the following after Table 3A:   
Table 3A applies when cables complying JIS C 
3662 or JIS C 3663 are used.  In case of other 
cables, cable entries shall be so designed that a 
conduit suitable for the cable used can be fitted. 
Class III equipment. 
N/A 
3.2.5.1 
Add the following to the last of first dashed 
paragraph. Or mains cords shall be of the sheathed 
type complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. 
 Add the following to the last of second dashed 
paragraph. Or mains cords shall be of the sheathed 
type complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. 
Delete 1) in Table 3B 
Class III equipment. 
N/A 
3.3.4 
Add the following note to Table 3D:   
Note  For cables other than those complying with 
JIS C 3662 or JIS C 3663, terminals shall be 
suitable for the size of the intended cables. 
Class III equipment. 
N/A 
3.3.7 
Add the following after the first  sentence:   
This requirement is not applicable to the external 
earthing terminal of Class 0I equipment. 
Class III equipment. 
N/A 
4.3.4 
Add the following after the first  sentence:   
This requirement also applies to those connections 
in Class 0I equipment, where CLEARANCE or 
CREEPAGE DISTANCES over BASIC 
INSULATION would be reduced to less than the 
values specified in 2.10. 
Class III equipment. 
N/A 
 
 
- Page 5 of 8 - 
 
 
www.nemko.com 
Report No.   241619 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
5.1.3 
Add a note after the first paragraph as follows:   
Note – Attention should be drawn to that majority of 
three-phase power system in Japan is of delta 
connection, and therefore, in that case, test is 
conducted using the test circuit from IEC 60990,  
figure 13.   
Class III equipment. 
N/A 
5.1.6 
Replacement: Replace Table 5A. 
 
 
 
7.2 
Add the following after the paragraph:   
However, the separation requirements and tests of 
6.2.1 a), b) and c) do not apply to a CABLE 
DISTRIBUTION SYSTEM if all of the following 
apply:  
− the circuit under consideration is a TNV-1 
CIRCUIT; and  
– the common or earthed side of the circuit is 
connected to the screen of the coaxial cable and to 
all accessible parts and circuits (SELV, accessible 
metal parts and LIMITED CURRENT CIRCUITS, if 
any); and  
– the screen of the coaxial cable is intended to be 
connected to earth in the building installation. 
No CDS and TNV circuit. 
N/A 
 
 
- Page 6 of 8 - 
 
 
www.nemko.com 
Report No.   241619 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
W.1 
Replace second and third sentence in the first 
paragraph with the following:   
This distinction between earthed and unearthed 
(floating) circuit is not the same as between CLASS 
I EQUIPMENT, CLASS 0I EQUIPMENT and 
CLASS II EQUIPMENT.  Floating circuits can exist 
in CLASS I EQUIPMENT or CLASS 0I 
EQUIPMENT and earthed circuits in CLASS II 
EQUIPMENT. 
Class III equipment. 
N/A 
Annex JA 
Addition: Add a new annex with the following 
contents.   
Annex JA (normative) Document shredding 
machines 
Document shredding machines shall also comply 
with the requirements of this annex except those of 
STATIONARY EQUIPMENT used by connecting 
directly to an AC MAINS SUPPLY of three-phase 
200V or more. 
Not Document shredding 
machines. 
N/A 
JA.1 
Markings and instructions In the easily visible part 
near the document-slot, by a method capable to 
make out clearly and not easily disappeared, and 
by easily understandable wording, shall indicate the 
symbol of;   
 
 
 and, also the following precautions for use;  
- that use by an infant/child may cause a hazard of 
injury etc.;  
- that a hand can be drawn into the mechanical 
section for shredding when touching the document-
slot;  
- that clothes can be drawn into the mechanical 
section for shredding when touching the document-
slot;  
- that hairs can be drawn into the mechanical 
section for shredding when touching the document-
slot; 
 in case of equipment incorporating a commutator 
motor, that equipment may catch fire or explode by 
spraying of flammable gas. 
Not Document shredding 
machines. 
N/A 
 
 
- Page 7 of 8 - 
 
 
www.nemko.com 
Report No.   241619 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
JA.2  
Inadvertent reactivation  
Any safety interlock which can be operated by 
means of the test finger, Figure JA.1, is considered 
to cause reactivation of the hazard.   
Compliance is checked by inspection and, where 
necessary, by a test with the test finger, Figure 
JA.1. 
Not Document shredding 
machines. 
N/A 
JA.3 
Isolating switch
  
Document shredding machines shall incorporate an 
isolating switch complying with sub-clause 3.4.2 as 
the device disconnecting the power of hazardous 
moving parts. For this switch, two-position (single-
use) switch or multi-position (multifunction) switch 
(e.g., slide switch) may be used.    
If two-position switch, the positions for  “ON” and 
“OFF” shall be indicated in accordance with sub-
clause 1.7.8. If multi-position switch, the position for 
“OFF” shall be indicated in accordance with sub-
clause 1.7.8 and other positions shall be indicated 
with proper terms or symbols.   
Compliance is checked by inspection. 
Not Document shredding 
machines. 
N/A 
JA.4 
Protection in operator access areas  
Any warning shall not be used instead of the 
structure for preventing access to hazardous 
moving parts. Document shredding machines shall 
comply with the following requirements. 
Push the test finger, Figure JA.1, into all openings 
in MECHANICAL ENCLOSURES without applying 
additional force. It shall not be possible to touch 
hazardous moving parts with the test finger. The 
document shredding machine is installed as 
intended, and all face of MECHANICAL 
ENCLOSURES are subjected to this test. Before 
testing with the test finger, remove the parts 
detachable without a tool.   
Push the wedge-probe, Figure JA.2, into the 
document-slot. And, against all directions of 
openings, if straight-cutting type, a force of 45 N 
shall apply to the probe, and 90 N if cross-cutting 
type. In this case, the weight of the probe shall not 
influence the test. Before testing withy the test 
finger, remove the parts detachable without a tool. 
It shall not be possible to touch any hazardous 
moving parts, including the shredding roller or the 
mechanical section for shedding, with the probe. 
Not Document shredding 
machines. 
N/A 