Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
27 of 73 
 
Template 7-09aal 
Figure 6. EFT Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
CONFIGURATION LEGEND 
 
1.  Test Laboratory (6 x 7 meters) 
2.  Ground Plane 
3.  Power Strip for Peripherals from power line filter  
4.  AC Power for Devices 
5.  Capacitive Coupling Clamp (grounded) 
6.  Mains Power for EUT 
7.  AC Power for Fast Transient Noise Generator (120V) 
8.  Fast Transient Noise Generator 
9.  Coupling Network 
10.  10cm Non-Conducting Platform  
11.  EUT 
12.  Associated System, if needed 
 
10 
8
 
6
 
5
11 
10 
12 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 
Phone (858) 755-5525 - Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Error! Reference 
source not 
found. 
Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
28 of 73 
 
Template 7-09aal 
4.13.  Power Line Surge Immunity: EN 61000-4-5: 2006 
 
ETSI 301 489-1 specifies the EN 61000-4-5 Standard as the basic procedure for power line surge immunity 
tests. This standard relates to the immunity requirements, test methods, and range of recommended test levels 
for low voltage equipment to unidirectional surges caused by over-voltages from switching and lightning 
transients. The standard configuration as outlined in EN 61000-4-5: 2006, section 7 was used. 
 
Each device was tested in a total of three surge configurations: 
 
Surge #1: Combination Wave, Line to Protective Earth with 9uF and 10Ohm, common mode, generator 
earthed. 
Surge #2: Combination Wave, Neutral to Protective Earth with 9uF and 10Ohm, common mode, generator 
earthed. 
Surge #3: Combination Wave, Line to Neutral with 18uF, differential mode, generator floated. 
 
For further information, please refer to the technical sections in the EN 61000-4-5: 2006 in addition to the test 
results section and photographs of the test set-up provided in this report. 
 
For Power line surge tests, the EUT meet at least performance Criterion B for ±2kV common mode and ±1kV 
differential mode surges in the AC power supply configuration. 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 
Phone (858) 755-5525 - Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Error! Reference 
source not 
found. 
Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
29 of 73 
 
Template 7-09aal 
Figure 7. Power Line Surge Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
CONFIGURATION LEGEND 
 
1.  Test Laboratory 
2.  AC power for Devices 
3.  Power strip for associated devices from power line filter 
4.  Ground Plane  
5.  Surge Generator 
6.  Surge Coupling Network 
7.  Nonconductive tables 80cm above Ground Plane 
8.  EUT 
9.  Associated System, if needed. 
 
6
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 
Phone (858) 755-5525 - Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Error! Reference 
source not 
found. 
Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
30 of 73 
 
Template 7-09aal 
4.14.Radio Frequency Conducted Common Mode Immunity: EN 61000-4-6 
 
ETSI 301 489-1 specifies the EN 61000-4-6 Standard as the basic standard for radio frequency conducted 
common mode disturbance testing. This standard relates to the immunity requirements, test methods, and range 
of recommended test levels for immunity to conducted disturbances induced by radio-frequency fields in the 
150 kHz to 80 MHz frequency range. The standard configuration as outlined in the EN 61000-4-6: 2009 was 
used. For further information, please refer to the technical sections of the EN 61000-4-6: 2009 publication in 
addition to the test results section and photographs of the test set-up provided in this report. 
 
For RF induced conducted common mode disturbances, ETSI 301 489 specifies that the EUT meet at least 
performance Criterion A for 3 Vrms, 1 kHz, 80% amplitude modulated waveform. 
 