JBL ON TOUR XTB (serv.man5) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
31 of 73
Template 7-09aal
Figure 8. RF Common Mode Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1. Test Laboratory
2. AC power for EUT
3. Ground Plane
4. 10cm wooden Platform
5. Test Generator
6. Current Probe
7. Coupling/Decoupling Network
8. Coupling/Decoupling Network
9. EUT
10. Associated System, if needed.
2. AC power for EUT
3. Ground Plane
4. 10cm wooden Platform
5. Test Generator
6. Current Probe
7. Coupling/Decoupling Network
8. Coupling/Decoupling Network
9. EUT
10. Associated System, if needed.
1
2
9
6
5
7
10
3
4
8
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
32 of 73
Template 7-09aal
4.15. Voltage Dips and Short Interruptions: EN 61000-4-11: 2004
ETSI 301 489-1 specifies the EN 61000-4-11 Standard as the basic standard for voltage variations immunity
testing. This standard relates to the immunity requirements, test methods, and range of recommended test levels
for immunity to variations in AC line voltage. The standard configuration as outlined in the EN 61000-4-11:
2004 was used. The EUT is powered up to a nominal voltage of 230 VAC 50 Hz, and then software-controlled
voltage dips and interruptions are introduced. The EUT is tested with a 30% reduction for 0.5 periods, repeated
once per minute for 3 repetitions. Next the dip is changed to a 60% reduction for 5 periods with the same rate
for 3 repetitions. Finally a voltage interruption is performed with a >95% reduction for 250 periods. This is also
repeated 3 times at 1-minute intervals.
For further information, please refer to the technical sections of the EN 61000-4-11: 2004 Standard in addition
to the test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
33 of 73
Template 7-09aal
Figure 9. Voltage Dips and Short Interruptions Test Setup Diagram
N
OT TO
S
CALE
CONFIGURATION LEGEND
1. Test Laboratory (6 X 6 meters)
2. AC Power for Devices
3. 120/208VAC/60Hz Power for Harmonics/Flicker Test Equipment
4. 115V/60 Hz Power Distribution Box
5. Power Source Rack with Computer Analysis System
6. Non-conducting table
7. EUT
3
4
1
2
6
7
5
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
34 of 73
Template 7-09aal
5. TEST RESULTS
5.1. Conducted Emissions Test Data
Client Harman
Multimedia
Temperature
24
°C
PAN #
12076-3
Relative Humidity
64
%
EUT Name
Bluetooth Portable Loudspeaker
Barometric Pressure 101.4
kPa
EUT Model
On Tour XTB
Test Location
Enclosure 1
Governing Doc
EN 301 489-1
Test Engineer
Alan Laudani
Basic Standard
EN 55022
Date
8-4-08
Nemko USA, Inc.
EN 55022 Class B Conducted Emissions
230VAC @ 50Hz, L1 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
20.0
30.0
40.0
50.0
60.0
70.0
80.0
Am
pl
it
ude (
dbuV)
10:56:20 AM, Thursday, August 07, 2008
Bluetooth
Nemko USA, Inc.
EN 55022 Class B Conducted Emissions
230VAC @ 50Hz, L2 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
20.0
30.0
40.0
50.0
60.0
70.0
80.0
Am
pl
it
ude (
dbuV)
01:22:35 PM, Thursday, August 07, 2008
Bluetooth
Click on the first or last page to see other ON TOUR XTB (serv.man5) service manuals if exist.