DOWNLOAD JBL ON TOUR XTB (serv.man5) Service Manual ↓ Size: 2.51 MB | Pages: 76 in PDF or view online for FREE

Model
ON TOUR XTB (serv.man5)
Pages
76
Size
2.51 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-tour-xtb-sm5.pdf
Date

JBL ON TOUR XTB (serv.man5) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 
Phone (858) 755-5525 - Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Error! Reference 
source not 
found. 
Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
31 of 73 
 
Template 7-09aal 
Figure 8. RF Common Mode Immunity Test Setup Diagram  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
CONFIGURATION LEGEND 
 
1.  Test Laboratory 
2.  AC power for EUT  
3.  Ground Plane 
4.  10cm wooden Platform 
5.  Test Generator 
6.  Current Probe 
7.  Coupling/Decoupling Network 
8.  Coupling/Decoupling Network 
9.  EUT 
10.  Associated System, if needed. 
 
7
10
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 
Phone (858) 755-5525 - Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Error! Reference 
source not 
found. 
Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
32 of 73 
 
Template 7-09aal 
4.15.  Voltage Dips and Short Interruptions: EN 61000-4-11: 2004 
 
ETSI 301 489-1 specifies the EN 61000-4-11 Standard as the basic standard for voltage variations immunity 
testing. This standard relates to the immunity requirements, test methods, and range of recommended test levels 
for immunity to variations in AC line voltage. The standard configuration as outlined in the EN 61000-4-11: 
2004 was used. The EUT is powered up to a nominal voltage of 230 VAC 50 Hz, and then software-controlled 
voltage dips and interruptions are introduced. The EUT is tested with a 30% reduction for 0.5 periods, repeated 
once per minute for 3 repetitions. Next the dip is changed to a 60% reduction for 5 periods with the same rate 
for 3 repetitions. Finally a voltage interruption is performed with a >95% reduction for 250 periods. This is also 
repeated 3 times at 1-minute intervals. 
 
For further information, please refer to the technical sections of the EN 61000-4-11: 2004 Standard in addition 
to the test results section and photographs of the test set-up provided in this report. 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 
Phone (858) 755-5525 - Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Error! Reference 
source not 
found. 
Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
33 of 73 
 
Template 7-09aal 
Figure 9. Voltage Dips and Short Interruptions Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
N
OT TO 
S
CALE
 
 
CONFIGURATION LEGEND 
 
1.  Test Laboratory (6 X 6 meters) 
2.  AC Power for Devices 
3.  120/208VAC/60Hz Power for Harmonics/Flicker Test Equipment 
4.  115V/60 Hz Power Distribution Box  
5.  Power Source Rack with Computer Analysis System 
6.  Non-conducting table 
7.  EUT 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121 
Phone (858) 755-5525 - Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Error! Reference 
source not 
found. 
Harman Multimedia - On Tour XTB - RTTE Test Report 
2009 11138368 EMC 
34 of 73 
 
Template 7-09aal 
5.  TEST RESULTS 
 
5.1.  Conducted Emissions Test Data 
 
Client Harman 
Multimedia 
Temperature 
24 
°C 
PAN # 
12076-3 
Relative Humidity 
64 
EUT Name 
Bluetooth Portable Loudspeaker 
Barometric Pressure  101.4 
kPa 
EUT Model  
On Tour XTB 
Test Location 
Enclosure 1 
Governing Doc 
EN 301 489-1 
Test Engineer 
Alan Laudani 
Basic Standard 
EN 55022 
Date 
8-4-08 
Nemko USA, Inc.
EN 55022 Class B Conducted Emissions
230VAC @ 50Hz, L1 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
20.0
30.0
40.0
50.0
60.0
70.0
80.0
Am
pl
it
ude (
dbuV)
10:56:20 AM, Thursday, August 07, 2008
Bluetooth
Nemko USA, Inc.
EN 55022 Class B Conducted Emissions
230VAC @ 50Hz, L2 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
20.0
30.0
40.0
50.0
60.0
70.0
80.0
Am
pl
it
ude (
dbuV)
01:22:35 PM, Thursday, August 07, 2008
Bluetooth
Page of 76
Display