JBL ON STAGEII (serv.man6) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
5 of 72
CERTIFICATION
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent
electromagnetic compatibility consulting and test laboratory.
Equipment.
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the
sample's immunity and emission characteristics, as of the test date(s), and for the design of the test sample
utilized to compile this report.
FR Fleury
Chip Fleury
Senior EMC Engineer
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
6 of 72
1. ADMINISTRATIVE DATA AND TEST SUMMARY
1.1. Administrative Data
CLIENT:
Harman Multimedia
8500 Balboa Blvd.
818 830-8764
CONTACT:
Robert Tang
DATE (S) OF TEST:
January 3, 2005 to January 5, 2005
EQUIPMENT UNDER TEST (EUT):
Computer Speaker System
Model
OnStage UD
Condition Upon Receipt
Suitable for Test
TEST SPECIFICATION:
Radio Frequency Emissions and Electromagnetic Immunity
tests in accordance with requirements of EN 55022 (1998),
A1(2000), A2(2003) and EN 55024 (1998), A1(2001),
A2(2003) as follows:
tests in accordance with requirements of EN 55022 (1998),
A1(2000), A2(2003) and EN 55024 (1998), A1(2001),
A2(2003) as follows:
Test Type
In Accordance with
Document
Document Title
Conducted and
Radiated Emissions
Radiated Emissions
EN 55022 (1998),
A1(2000), A2(2003)
A1(2000), A2(2003)
Class ““B”
Specifications for Limits and Methods of Measurement
of Radio Disturbance Characteristics of Information
Technology Equipment (ITE)
of Radio Disturbance Characteristics of Information
Technology Equipment (ITE)
Power Line Harmonics
EN 61000-3-2 (2000),
A1(2001), A2(2005)
Electromagnetic Compatibility, Limits for Harmonic
Current Emissions, Equipment Input Current
Current Emissions, Equipment Input Current
less than
or equal to
16A
Power Line Flicker
EN 61000-3-3 (1995),
A1(2001)
A1(2001)
Electromagnetic Compatibility, Limitation of Voltage
Fluctuations and Flicker In Low-Voltage Supply
Systems for Equipment with Rated Current
Fluctuations and Flicker In Low-Voltage Supply
Systems for Equipment with Rated Current
less than or
equal to
16A
Electrostatic Discharge
Immunity
Immunity
IEC 61000-4-2 (2001)
Electromagnetic Compatibility for Industrial Process
Measurement and Control Equipment Electrostatic
Discharge Requirements
Measurement and Control Equipment Electrostatic
Discharge Requirements
Radio Frequency
Immunity
Immunity
IEC 61000-4-3 (2002)
Electromagnetic Compatibility, Basic Immunity
Standard, Radiated Radio Frequency Electromagnetic
Field, Immunity Test
Standard, Radiated Radio Frequency Electromagnetic
Field, Immunity Test
Electrical Fast
Transient Burst
Immunity
Transient Burst
Immunity
IEC 61000-4-4 (2004)
Electromagnetic Compatibility for Industrial Process
Measurement and Control Equipment Electrical Fast
Transient / Burst Requirements
Measurement and Control Equipment Electrical Fast
Transient / Burst Requirements
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
7 of 72
Test Specifications Continued:
Power Line Surge
Immunity
Immunity
IEC 61000-4-5 (2001)
Electromagnetic Compatibility, Power Line Surge
Immunity
Immunity
RF Common Mode
Immunity
Immunity
IEC 61000-4-6 (2004)
Electromagnetic Compatibility - Basic Immunity Standard -
Conducted Disturbances Induced By Radio-Frequency
Fields - Immunity Test
Conducted Disturbances Induced By Radio-Frequency
Fields - Immunity Test
Power Frequency
Magnetic Field
Magnetic Field
IEC 61000-4-8 (2001)
Electromagnetic Compatibility, Testing and Measurement
Techniques for Power Frequency Magnetic Field,
Immunity Test
Techniques for Power Frequency Magnetic Field,
Immunity Test
Voltage Dips and Short
Interruptions Immunity
Interruptions Immunity
IEC 61000-4-11(2004)
Electromagnetic Compatibility - Testing and Measurement
Techniques - Voltage Dips, Short Interruptions and Voltage
Variations Immunity Tests
Techniques - Voltage Dips, Short Interruptions and Voltage
Variations Immunity Tests
1.2. Test Summary
1.2.1.
Emissions Test Summary
Specification
Frequency Range
Compliance Status
EN 55022 (1998), A1(2000),
A2(2003) , Class “B"
Conducted Emissions
A2(2003) , Class “B"
Conducted Emissions
0.15 MHz – 30 MHz
PASS
EN 55022 (1998), A1(2000),
A2(2003) , Class “B
Telecom Conducted Emissions
A2(2003) , Class “B
Telecom Conducted Emissions
0.15 MHz – 30 MHz
N/A
EN 55022 (1998), A1(2000),
A2(2003) , Class “B
Radiated Emissions
A2(2003) , Class “B
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 61000-3-2 (2000),
A1(2001), A2(2005)
Power Line Harmonics
up to the 40
th
Harmonic
Outside of Test
Requirement
EN 61000-3-3 (1995),
A1(2001)
Power Line Flicker
Power Line Flicker
less than or equal to
4% Maximum Relative
Voltage Change; Value of D(T)
less than or equal
to
3% for more than 200 Ms
Outside of Test
Requirement
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
8 of 72
1.2.2.
Immunity Test Summary
Specification
Minimum Criterion
Level Required
as per EN 55024
Criterion Level
Tested
Compliance
Status
IEC 61000-4-2 (2001)
- ESD Immunity
- ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
IEC 61000-4-3 (2002)
-Radio Frequency
Immunity
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
PASS
IEC 61000-4-4 (2004)
-Electrical Fast
-Electrical Fast
Transient Immunity
Criterion B
power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV;
up to ±2kV process/control lines;
I/O Line Pulses of ± 0.5 kV
PASS
IEC 61000-4-5 (2001)
-Surge Immunity
-Surge Immunity
Criterion B
±2kV common mode surges,
±1kV differential mode surges
Criterion C
±2kV Common Mode Surges,
±1kV Differential Mode Surges
PASS
IEC 61000-4-6 (2004)
-RF Common Mode
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion A
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
PASS
IEC 61000-4-8 (2001)
Power Frequency
Magnetic Field
Magnetic Field
Criterion A
Helmholtz coil at 50 Hz,
to 30 amps (rms) per meter
Criterion A
Helmholtz coil at 50 Hz,
to 30 amps (rms) per meter
Outside of Test
Requirement
IEC 61000-4-11(2004)
- Voltage Dips and
- Voltage Dips and
Short Interruptions
Criterion B and C
Voltage Dips of 30% and >95%;
Interruptions of >95%.
Criterion B and C
Voltage Dips of 30% and >60%;
Interruptions of >95%.
PASS
Test Supervisor:
FR Fleury
Floyd Fleury, Nemko USA, Inc.
Refer to the test results section for further details.
Click on the first or last page to see other ON STAGEII (serv.man6) service manuals if exist.