JBL ON STAGEII (serv.man6) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
29 of 72 
 
Figure 7.   Radio Frequency Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
 
CONFIGURATION LEGEND 
 
1.  Test laboratory 
2.  Shielded anechoic chamber (Anechoic absorber material on walls and ceiling; ferrite tiles on ceiling and floor) 
3.  Power Line filters and power distribution breaker box 
4.  Power strip for EUT and peripherals 
5.  Transmit antennas 
6.  E-Field sensor 
7.  Monitoring camera for EUT 
8.  Broadband power amplifiers 
9.  E-Field probe monitoring system 
10.  Signal Generators 
11.  Non-Conducting table 
12.  EUT: Computer Speaker System and Associated System 
 
3 m 
10 
11 
12 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
30 of 72 
 
3.11.  Electrical Fast Transient Immunity: IEC 61000-4-4 (2004) 
 
 
EN 55024 specifies the IEC 61000-4-4 Standard as the basic procedure for electrical fast transient testing. IEC 
61000-4-4 (2004) 
 
defines the immunity requirements and test methods for equipment that are required to withstand high-voltage 
transients coupled on supply, signal and control ports.  The standard configuration for “type tests” outlined in 
IEC 61000-4-4 (2004) 
 is 
used.  For further information, please refer to the technical sections in the IEC 61000-4-4 (2004) 
 in 
addition to the test results section and photographs of the test set-up provided in this report.  
 
For electrical fast transient/burst tests, EN 55024 requires that the EUT meet at least performance Criterion B 
for ± 1 kV Power line and ± 0.5 kV signal line transients. 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
31 of 72 
 
Figure 8.   EFT Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
CONFIGURATION LEGEND 
 
1.  Test Laboratory (6 x 7 meters) 
2.  Ground Plane 
3.  Power Strip for Peripherals from power line filter  
4.  DC Power for Devices 
5.  Capacitive Coupling Clamp (grounded) 
6.  Mains Power for EUT 
7.  AC Power for Fast Transient Noise Generator (120V) 
8.  Fast Transient Noise Generator 
9.  Coupling Network 
10.  10cm Non-Conducting Platform  
11.  EUT: Computer Speaker System 
12.  Associated System 
 
10 
8
 
6
 
5
11 
10 
12 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
32 of 72 
 
3.12.  Power Line Surge Immunity: IEC 61000-4-5 (2001) 
  
 
EN 55024 specifies the IEC 61000-4-5 Standard as the basic procedure for power line surge immunity tests.  
This standard relates to the immunity requirements, test methods, and range of recommended test levels for 
low voltage equipment to unidirectional surges caused by over-voltages from switching and lightning 
transients.  The standard configuration as outlined in IEC 61000-4-5 (2001) 
 , 
section 7 was used. 
 
Each device was tested in a total of three surge configurations: 
 
Surge #1: Combination Wave, Line to Protective Earth with 9uF and 10Ohm, common mode, generator 
earthed. 
Surge #2: Combination Wave, Neutral to Protective Earth with 9uF and 10Ohm, common mode, 
generator earthed. 
Surge #3: Combination Wave, Line to Neutral with 18uF, differential mode, generator floated. 
 
For further information, please refer to the technical sections in the IEC 61000-4-5 (2001) 
  
in addition to the test results section and photographs of the test set-up provided in this report. 
 
For Power line surge tests, the EUT meet at least performance Criterion B for ±2kV common mode and ±1kV 
differential mode surges in the AC power supply configuration. 
 
Page of 72