JBL ON STAGE (serv.man5) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
33 of 80
Figure 10. Voltage Dips and Short Interruptions Test Setup Diagram
N
OT TO
S
CALE
CONFIGURATION LEGEND
1.
Test Laboratory (6 X 6 meters)
2.
AC Power for Devices
3.
120/208VAC/60Hz Power for Harmonics/Flicker Test Equipment
4.
115V/60 Hz Power Distribution Box
5.
Power Source Rack with Computer Analysis System
6.
Non-conducting table
7.
EUT: Speaker System and Associated System
3
4
1
2
6
7
5
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
34 of 80
5. FCC Test Results
5.1. Conducted Emissions Test Data
Client
Harman Multimedia
Temperature
74
deg F
PAN #
24-310-HAR
Relative Humidity
46
%
EUT Name
Speaker System
Barometric Pressure
30.32
Hg
EUT Model
JBL OnStage
Test Location
Enclosure 1
Governing Doc
CFR 47, Part 15B
Test Engineer
Rodel Resolme
Basic Standard
Sec. 15.107
Date
May 21, 2004
Nemko USA, Inc.
FCC Class B Conducted Emissions
120VAC @ 60Hz, L1 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
Amplitude (dbuV)
08:05:45 AM, Friday, May 21, 2004
Harman Multimedia
JBL Onstage Speaker System with CDplayer
24-310-HAR
JBL Onstage Speaker System with CDplayer
24-310-HAR
Nemko USA, Inc.
FCC Class B Conducted Emissions
120VAC @ 60Hz, L1 PK, QP = 0, AV = X
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
Amplitude (dbuV)
07:52:58 AM, Friday, May 21, 2004
Harman Multimedia
JBL Onstage Speaker System with CDplayer
24-310-HAR
JBL Onstage Speaker System with CDplayer
24-310-HAR
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
35 of 80
Conducted Emissions Test Equipment
Client
Harman Multimedia
EUT Name
Speaker System
PAN #
24-310-HAR
EUT Model
JBL OnStage
Device Type
Model #
Asset #
Used
Cal Done
Cal Due
Pre-Amplifier
Amplifier, HP
8447A
342
Amplifier, HP
8447A
166
Amplifier, HP
8447A
603
Filter / Limiter
High Pass Filter, Solar
7801-5.0
542
X
02/27/04
02/27/05
High Pass Filter, Solar
8310-1.0
559
Transient Limiter, HP
11947A
682
X
08/06/03
08/06/04
Transducer
LISN, EMCO
3825/2 – FCC
147
LISN, Electro-Metrics
LISN – VDE
425
V-Network LISN, Solar
9348-50-R-24-BNC
384
X
05/29/03
05/29/04
V-Network LISN, Solar
9348-50-R-24-BNC
395
Voltage Line Probe, EMCO
3701
471
LISN, Solar
8602-50-TS-50-N
424
LISN, Solar
8602-50-TS-50-N
423
Spectrum Analyzer / Receiver
Quasi-Peak Adapter, HP
Spectrum Analyzer Display, HP
Spectrum Analyzer, HP
Spectrum Analyzer Display, HP
Spectrum Analyzer, HP
85650A
85662A
8566B
85662A
8566B
533
404
104
404
104
RF Preselector, HP
85650A
673
Quasi-Peak Adapter, HP
Spectrum Analyzer Display, HP
Spectrum Analyzer, HP
Spectrum Analyzer Display, HP
Spectrum Analyzer, HP
85650A
85662A
8568B
85662A
8568B
438
107
422
107
422
Quasi-Peak Adapter, HP
Spectrum Analyzer Display, HP
Spectrum Analyzer, HP
Spectrum Analyzer Display, HP
Spectrum Analyzer, HP
85650A
85662A
8566B
85662A
8566B
538
537
711
537
711
X
04/13/04
10/13/04
RF Preselector, HP
85685A
403
Spectrum Analyzer, Advantest
R3261
523
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
36 of 80
5.2. Radiated Emissions Test Data
San Diego Headquarters:
11696 Sorrento Valley Rd.
San Diego, CA 92121
Tel: (858) 755-5525
NEMKO USA, Inc.
Fax: (858) 452-1810
Radiated Emissions Data
Complete
X
Job # :
24-310-HAR
Test # :
Preliminary
Page
1
of
1
Client Name :
Harman Multimedia
EUT Name :
JBL OnStage Speaker System
EUT Model # :
EUT Part # :
EUT Serial # :
EUT Config. :
EUT Part # :
EUT Serial # :
EUT Config. :
with CD Player
Specification :
CFR47 Part 15, Subpart B, Class B
Reference :
Rod. Ant. #:
NA
Temp. (deg. C) :
Date : 5/24/2004
Bicon Ant.#:
116
Humidity (%) :
Time :
Log Ant.#:
110
EUT Voltage :
120VAC
Staff : Rodel Resolme
DRG Ant. #
NA
EUT Frequency :
60Hz
Photo ID:
Dipole Ant.#:
NA
Phase:
Peak Bandwidth: 100 kHz
Cable#:
SOATS
Location:
SOATS
Video Bandwidth 100 kHz
Preamp#:
826
Distance:
10m
Spec An.#:
534
QP #:
438
PreSelect#:
NA
Meas.
Ant.
Atten.
Meter
Antenna
Path
RF
Corrected
Spec.
CR/SL
Pass
Freq.
Pol.
Reading
Factor
Loss
Gain
Reading
limit
Diff.
Fail
(MHz)
(H/V)
(dB)
(dBuV)
(dB)
(dB)
(dB)
(dBuV/m)
(dBuV/m)
(dB)
Unc.
Comment
48
V
0
42
13.8
1.9
32.6
25.1
30.0
-4.9
Pass
54.24
V
0
44
11.9
2.0
32.5
25.4
30.0
-4.6
Pass
68.77
V
0
45.6
7.7
2.3
32.4
23.2
30.0
-6.8
Pass
114.11
V
0
42
12.1
3.1
32.5
24.7
33.5
-8.8
Pass
139.97
V
0
30
14.8
3.3
32.6
15.5
33.5
-18.0
Pass
168.04
V
0
33.1
16
3.8
32.7
20.2
33.5
-13.3
Pass
194.91
V
0
39
17.3
4.2
32.8
27.7
33.5
-5.8
Pass
203.41
V
0
39
11.6
4.2
32.7
22.1
33.5
-11.4
Pass
237.22
H
0
49.2
10.9
4.6
32.7
32.0
36.0
-4.0
Pass
271.21
V
0
45.2
13
4.9
32.8
30.3
36.0
-5.7
Pass
Click on the first or last page to see other ON STAGE (serv.man5) service manuals if exist.