JBL ON STAGE (serv.man5) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
29 of 80
Figure 8. RF Common Mode Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1.
Test Laboratory
2.
DC power for EUT
3.
Ground Plane
4.
10cm wooden Platform
5.
Test Generator
6.
Current Probe
7.
Coupling/Decoupling Network
8.
Coupling/Decoupling Network
9.
EUT: Speaker System
10. Associated System
1
2
9
6
5
7
10
3
4
8
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
30 of 80
4.12. Power Frequency Magnetic Field Immunity: IEC 61000-4-11(2001)
This test subjects devices to the fields produced by current carrying conductors of standard building power.
Testing was performed in accordance with IEC 61000-4-8. The standard configuration as outlined in IEC 61000-
4-8 was used. For further information, please refer to the technical sections of IEC 61000-4-8 in addition to the
test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
31 of 80
Figure 9. Power Frequency Magnetic Field Immunity Test Setup
NOT TO SCALE
CONFIGURATION LEGEND
1.
Test laboratory
2.
AC Power for devices
3.
DC Power Supply
4.
Helmholtz Coil
5.
Ground Plane on Non-Conductive Table
6.
EUT: Speaker System on 10cm blocks
1
2
3
4
5
6
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
32 of 80
4.13. Voltage Dips and Short Interruptions: IEC 61000-4-11(2001)
This test subjects the EUT to power network faults and “brownouts”. Testing was performed in accordance
with IEC 61000-4-11. The standard configuration as outlined in the IEC 61000-4-11 was used. The EUT is
powered up to a nominal voltage of 230 VAC 50 Hz, and then software-controlled voltage dips and
interruptions are introduced. For further information, please refer to the technical sections of the IEC 61000-4-
11 in addition to the test results section and photographs of the test set-up provided in this report.