JBL ON STAGE (serv.man5) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
25 of 80
Figure 6. EFT Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1.
Test Laboratory (6 x 7 meters)
2.
Ground Plane
3.
Power Strip for Peripherals from power line filter
4.
DC Power for Devices
5.
Capacitive Coupling Clamp (grounded)
6.
Mains Power for EUT
7.
AC Power for Fast Transient Noise Generator (120V)
8.
Fast Transient Noise Generator
9.
Coupling Network
10. 10cm Non-Conducting Platform
11. EUT: Speaker System
12. Associated System
11. EUT: Speaker System
12. Associated System
1
10
2
3
4
9
8
6
7
5
11
10
12
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
26 of 80
4.10. Power Line Surge Immunity: IEC 61000-4-5 (1995),A1(2001)
This test simulates a lightning event by inducing transients onto the AC/DC power supply lines in common
and differential mode. Testing was performed in accordance with IEC 61000-4-5.
Each device was tested in a total of three surge configurations:
Surge #1: Combination Wave, Line to Protective Earth with 9uF and 10Ohm, common mode, generator
earthed.
Surge #2: Combination Wave, Neutral to Protective Earth with 9uF and 10Ohm, common mode, generator
earthed.
Surge #3: Combination Wave, Line to Neutral with 18uF, differential mode, generator floated.
For further information, please refer to the technical sections in the IEC 61000-4-5 in addition to the test results
section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
27 of 80
Figure 7. Power Line Surge Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1.
Test Laboratory
2.
AC power for Devices
3.
Power strip for associated devices from power line filter
4.
Copper Ground Plane
5.
Surge Generator
6.
Surge Coupling Network
7.
Nonconductive tables 80cm above Ground Plane
8.
EUT: Speaker System
9.
Associated System
3
2
4
7
1
6
5
7
8
9
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
28 of 80
4.11. Radio Frequency Conducted Common Mode Immunity: IEC 61000-4-6
(1996)A1(2000)
This test injects a disturbance directly onto AC/DC power and signal I/O cables. Testing was performed in
accordance with IEC 61000-4-6. The standard configuration as outlined in the IEC 61000-4-6 was used. For
further information, please refer to the technical sections of the IEC 61000-4-6 publication in addition to the test
results section and photographs of the test set-up provided in this report.
Click on the first or last page to see other ON STAGE (serv.man5) service manuals if exist.