EMC - CB Certificate
Brand
Device
Audio
File
on-stage-sm5.pdf
Date

JBL ON STAGE (serv.man5) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
May 21, 2004 
Harman Multimedia  JBL OnStage   EMC Test Report 
2004 050310 EMC 
 
21 of 80 
 
Figure 4.   ESD Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
N
OT TO 
S
CALE 
 
CONFIGURATION LEGEND 
 
1. 
Test Laboratory (6 x 7 meters) 
2. 
Vertical Conducting Wall (3 x 3 m, grounded) 
3. 
Ground Plane (14 square meters) 
4. 
Ground Rod extending 3 m under ground plane 
5. 
Non-Conducting table for ESD Simulator Control Box 
6. 
ESD Simulator Control Box on cart 
7. 
Electro-Static Discharge (ESD) Gun (hand held, grounded to grounding rod) 
8. 
DC power for devices 
9. 
Ground strap with two 470kOhm resistors 
10.  Grounding Strap 
11.  Horizontal Coupling Plane, grounded to Grounding Rod 
12.  Insulating Mat 
13.  Vertical Coupling Plane 
14.  EUT: Speaker System and Associated System 
 
 
11 
12 
10 
13 
14 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
May 21, 2004 
Harman Multimedia  JBL OnStage   EMC Test Report 
2004 050310 EMC 
 
22 of 80 
 
 
 
4.8.  Radio Frequency Immunity: IEC IEC 61000-4-3 (2002),A1(2002) 
 
This test bombards the EUT with electric fields that may couple into the system via chassis slots and interface 
cables and evaluates the product’s immunity.  Testing was performed in accordance with IEC 61000-4-3.  The 
RF immunity test entails subjecting the equipment under test to a uniform field of radiated electromagnetic 
energy of a specified field strength and frequency, and monitoring the functionality of the device as the 
frequency is swept over a specified frequency range.   
 
The EUT is set up inside a shielded, semi-anechoic chamber with a radiating antenna at a distance of 3 meters 
from the EUT.  For further information, please refer to the technical sections in the IEC 61000-4-3 publication in 
addition to the test results section and photographs of the test set-up provided in this report. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
May 21, 2004 
Harman Multimedia  JBL OnStage   EMC Test Report 
2004 050310 EMC 
 
23 of 80 
 
Figure 5.   Radio Frequency Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
 
CONFIGURATION LEGEND 
 
1. 
Test laboratory 
2. 
Shielded anechoic chamber (Anechoic absorber material on walls and ceiling; ferrite tiles on ceiling and floor) 
3. 
Power Line filters and power distribution breaker box 
4. 
Power strip for EUT and peripherals  
5. 
Transmit antennas 
6. 
E-Field sensor 
7. 
Monitoring camera for EUT 
8. 
Broadband power amplifiers 
9. 
E-Field probe monitoring system 
10.  Signal Generators 
11.  Non-Conducting table 
12.  EUT: Speaker System and Associated System 
 
3 m 
10 
11 
12 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
May 21, 2004 
Harman Multimedia  JBL OnStage   EMC Test Report 
2004 050310 EMC 
 
24 of 80 
 
 
4.9.  Electrical Fast Transient Immunity: IEC 61000-4-4 (1995)A1(2000),A2(2001) 
 
This test injects a transient/burst interference onto the AC/DC power supply and signal I/O lines.  Testing was 
performed in accordance with IEC 61000-4-4.  The standard configuration for “type tests” outlined in IEC 61000-
4-4 is used.  For further information, please refer to the technical sections in the IEC 61000-4-4 in addition to the 
test results section and photographs of the test set-up provided in this report.  