JBL ON STAGE III IIIP (serv.man6) EMC - CB Certificate ▷ View online
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 49 of 66
14.4.Severity Levels and Performance Criterion
14.4.1.Severity level
Test Level
%U
T
Voltage dip and
short interruptions
%U
T
Performance
Criterion
Duration
(in period)
0 100
C 250
0 100
B 0.5
70 30
C
25
14.4.2.Performance criterion : B & C
14.5.EUT Configuration
The configuration of EUT are listed in Section 3.5.
14.6.Operating Condition of EUT
Same as Conducted Emission test which is listed in Section 3.6. except the test set up
replaced by Section 14.2.
replaced by Section 14.2.
14.7.Test Procedure
1) Set up the EUT and test generator as shown on Section 14.2.2.
2) The interruptions is introduced at selected phase angles with specified duration.
3) Record any degradation of performance.
2) The interruptions is introduced at selected phase angles with specified duration.
3) Record any degradation of performance.
14.8.Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
The EUT was tested and all the test results are listed in next page.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 50 of 66
Voltage Dips And Interruptions Test Results
Audix Technology (Shenzhen) Co., Ltd.
Date : 07/26/2007
Applicant
: Harman Multimedia DBA
Harman Motive Inc.
Test Date
:
Jul.08, 2007
EUT
: Computer Speaker System
Temperature
: 24
℃
M/N
: jbl on stage lll
Humidity
: 52
%
Power Supply
:
DC 12V Adaptor Input AC
230V/50Hz
230V/50Hz
Test Mode
: Data Transmitting
Test Engineer
: Jolly Pressure
:
100.6KPa
Test Level
% U
T
Voltage Dips &
Short
Interruptions
% U
T
Duration (in period)
Phase Angle
Criterion
Result
0 100 0.5P
0
。
-360
。
B PASS
70 30 25P
0
。
-360
。
C PASS
0 100 250P
0
。
-360
。
C PASS
Remark: U
T
is the rated voltage for the equipment.
Test Equipment :
Main Interference Simulator:
(HEAFELY PLINE 1610)
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 51 of 66