JBL ON STAGE III IIIP (serv.man6) EMC - CB Certificate ▷ View online

   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 41 of 66 
 
 
Surge Immunity Test Results
 
Audix Technology (Shenzhen) Co., Ltd. 
                                                        Date : 07/26/2007 
Applicant 
: 
Harman Multimedia DBA Harman 
Motive Inc.
 
Test Date 
: 
Jul.12, 2007 
EUT 
: 
Computer Speaker System 
Temperature 
: 
25
 
M/N 
: 
jbl on stage lll 
Humidity 
: 
50
 
Power Supply 
DC 12V Adaptor Input AC 
230V/50Hz 
Test Mode 
:   Data Transmitting 
Test Engineer 
Shelle Criterion 
: B 
Pressure 
100.6KPa 
 
 
 
Location 
Polarity 
Phase Angle
No of Pulse 
Pulse Voltage 
(kV) 
Result 
L-N 
± 
0 5  1.0 
PASS 
 
± 
90 5  1.0 
PASS 
 
± 
180 5 
1.0 
PASS 
 
± 
270 5 
1.0 
PASS 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Test Equipment : 
Surge Tester Psurge4.1 
 
 
 
 
 
 
   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 42 of 66 
 
 
12. INJECTED CURRENTS SUSCEPTIBILITY TEST 
12.1.Test Equipments 
Item Equipment 
Manufacturer Model No. 
Serial No.  Last Cal. 
Cal. 
Interval 
1.  
Signal 
Generator 
HP 
8648A 
3625U00573 
May 11, 07 1 Year 
2.  
Amplifier 
AR 
25A250A 
17028 
NCR 
NCR 
3.  
Amplifier 
AR 
500A100 
17034 
NCR 
NCR 
4.  
CDN 
FCC 
FCC-801-M2-25
47 
May 11, 07 1 Year 
5.  
CDN 
FCC 
FCC-801-M3-25
107 
May 11, 07 1 Year 
6.  
PC 
N/A 
486DX2 
N/A 
N/A 
N/A 
7.   RF Cable 
MIYAZAKI 5D-2W 
No.1/2 
Mar.05, 07 1/2 Year 
8.  
EM Injection Clamp 
FCC 
F-203I-23mm  403 
May 11, 07 1 Year 
9.  
CDN 
FCC 
F-203I-DCN-2
3mm 
152 
May 11, 07 1 Year 
12.2.Block Diagram of Test Setup 
12.2.1.Block Diagram of the EUT 
 
 
 
 
 
 
 
 
 
 
 
 
 
    (EUT: Computer Speaker System) 
 
12.2.2.Block Diagram of Test Setup 
 
 
 
 
 
 
 
 
 
 
 
 
Ground Reference Support 
EUT and 
Support System
 
CDN 
AC Mains 
Signal 
Generator 
Power 
Amplifier 
Personal Computer Control System 
0.1 m
PC  
AC Mains
 
Keyboard 
Mouse 
EUT 
AC Mains 
Monitor
a: Audio Cable 
b: USB Cable 
 : Core 
a
Adaptor
b
   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 43 of 66 
 
12.3.Test Standard 
EN55024: 1998+A1:2001+A2: 2003 (IEC61000-4-6:2006) 
(Severity Level 2 at 3V (r.m.s.) and frequency is from 0.15MHz to 80MHz) 
12.4.Severity Levels and Performance Criterion 
12.4.1.Severity level 
Level 
Voltage Level (e.m.f.) V
10. 1 
11. 3 
12. 10 
X Special 
12.4.2.Performance criterion: A 
12.5.EUT Configuration 
The configuration of EUT are listed in Section 3.5. 
12.6.Operating Condition of EUT 
Same as Conducted Emission test which is listed in Section 3.6. except the test set up 
replaced by Section 12.2. 
12.7.Test Procedure 
1)  Set up the EUT, CDN and test generators as shown on Section 12.2.2. 
2)  Let the EUT work in test mode and test it. 
3)  The EUT are placed on an insulating support 0.1m high above a ground 
reference plane. CDN (coupling and decoupling device) is placed on the ground 
plane about 0.3m from EUT. Cables between CDN and EUT are as short as 
possible, and their height above the ground reference plane shall be between 30 
and 50 mm (where possible). 
4)  The disturbance signal described below is injected to EUT through CDN. 
5)  The EUT operates within its operational mode(s) under intended climatic 
conditions after power on. 
6)  The frequency range is swept from 0.150MHz to 80MHz using 3V signal level, 
and with the disturbance signal 80% amplitude modulated with a 1kHz sine 
wave. 
7)  The rate of sweep shall not exceed 1.5*10
-3
decades/s. Where the frequency is 
swept incrementally, the step size shall not exceed 1% of the start and thereafter 
1% of the preceding frequency value. 
8)  Recording the EUT operating situation during compliance testing and decide the 
EUT immunity criterion. 
12.8.Test Results 
PASS. 
 
The EUT was tested and all the test results are listed in next page. 
   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 44 of 66 
 
 
Injected Currents Susceptibility Test Results
 
Audix Technology (Shenzhen)Co.,Ltd. 
Date : 07/26/2007 
Applicant 
: 
Harman Multimedia DBA Harman 
Motive Inc.
 
Test Date 
: 
Jul.08, 2007 
EUT 
: 
Computer Speaker System 
Temperature 
: 
24
 
M/N 
: 
jbl on stage lll 
Humidity 
: 
52
 
Power Supply 
: 
DC 12V Adaptor Input AC 
230V/50Hz 
Test Mode 
: 
Data Transmitting 
Test Engineer 
Jolly Criterion 
: A 
Pressure 
100.6KPa 
 
 
 
Frequency 
Range 
(MHz) 
Injected Position
Voltage Level 
(e.m.f.) 
Criterion Result 
0.15 ~ 20 
AC Mains 
3V(rms), 
Unmodulated 
A PASS 
20 ~ 80 
AC Mains 
3V(rms), 
Unmodulated 
A PASS 
 
Remark 1. Modulation Signal:1kHz 80% AM 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 