JBL ON STAGE III IIIP (serv.man6) EMC - CB Certificate ▷ View online
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 41 of 66
Surge Immunity Test Results
Audix Technology (Shenzhen) Co., Ltd.
Date : 07/26/2007
Applicant
:
Harman Multimedia DBA Harman
Motive Inc.
Motive Inc.
Test Date
:
Jul.12, 2007
EUT
:
Computer Speaker System
Temperature
:
25
℃
M/N
:
jbl on stage lll
Humidity
:
50
%
Power Supply
:
DC 12V Adaptor Input AC
230V/50Hz
230V/50Hz
Test Mode
: Data Transmitting
Test Engineer
:
Shelle Criterion
: B
Pressure
:
100.6KPa
Location
Polarity
Phase Angle
No of Pulse
Pulse Voltage
(kV)
Result
L-N
±
0 5 1.0
PASS
±
90 5 1.0
PASS
±
180 5
1.0
PASS
±
270 5
1.0
PASS
Test Equipment :
Surge Tester Psurge4.1
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 42 of 66
12. INJECTED CURRENTS SUSCEPTIBILITY TEST
12.1.Test Equipments
Item Equipment
Manufacturer Model No.
Serial No. Last Cal.
Cal.
Interval
Interval
1.
Signal
Generator
HP
8648A
3625U00573
May 11, 07 1 Year
2.
Amplifier
AR
25A250A
17028
NCR
NCR
3.
Amplifier
AR
500A100
17034
NCR
NCR
4.
CDN
FCC
FCC-801-M2-25
47
May 11, 07 1 Year
5.
CDN
FCC
FCC-801-M3-25
107
May 11, 07 1 Year
6.
PC
N/A
486DX2
N/A
N/A
N/A
7. RF Cable
MIYAZAKI 5D-2W
No.1/2
Mar.05, 07 1/2 Year
8.
EM Injection Clamp
FCC
F-203I-23mm 403
May 11, 07 1 Year
9.
CDN
FCC
F-203I-DCN-2
3mm
3mm
152
May 11, 07 1 Year
12.2.Block Diagram of Test Setup
12.2.1.Block Diagram of the EUT
(EUT: Computer Speaker System)
12.2.2.Block Diagram of Test Setup
Ground Reference Support
EUT and
Support System
CDN
AC Mains
Signal
Generator
Power
Amplifier
Personal Computer Control System
0.1 m
PC
AC Mains
Keyboard
Mouse
EUT
AC Mains
Monitor
a: Audio Cable
b: USB Cable
: Core
b: USB Cable
: Core
a
Adaptor
b
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 43 of 66
12.3.Test Standard
EN55024: 1998+A1:2001+A2: 2003 (IEC61000-4-6:2006)
(Severity Level 2 at 3V (r.m.s.) and frequency is from 0.15MHz to 80MHz)
(Severity Level 2 at 3V (r.m.s.) and frequency is from 0.15MHz to 80MHz)
12.4.Severity Levels and Performance Criterion
12.4.1.Severity level
Level
Voltage Level (e.m.f.) V
10. 1
11. 3
12. 10
X Special
12.4.2.Performance criterion: A
12.5.EUT Configuration
The configuration of EUT are listed in Section 3.5.
12.6.Operating Condition of EUT
Same as Conducted Emission test which is listed in Section 3.6. except the test set up
replaced by Section 12.2.
12.7.Test Procedure
1) Set up the EUT, CDN and test generators as shown on Section 12.2.2.
2) Let the EUT work in test mode and test it.
3) The EUT are placed on an insulating support 0.1m high above a ground
2) Let the EUT work in test mode and test it.
3) The EUT are placed on an insulating support 0.1m high above a ground
reference plane. CDN (coupling and decoupling device) is placed on the ground
plane about 0.3m from EUT. Cables between CDN and EUT are as short as
possible, and their height above the ground reference plane shall be between 30
and 50 mm (where possible).
plane about 0.3m from EUT. Cables between CDN and EUT are as short as
possible, and their height above the ground reference plane shall be between 30
and 50 mm (where possible).
4) The disturbance signal described below is injected to EUT through CDN.
5) The EUT operates within its operational mode(s) under intended climatic
5) The EUT operates within its operational mode(s) under intended climatic
conditions after power on.
6) The frequency range is swept from 0.150MHz to 80MHz using 3V signal level,
and with the disturbance signal 80% amplitude modulated with a 1kHz sine
wave.
wave.
7) The rate of sweep shall not exceed 1.5*10
-3
decades/s. Where the frequency is
swept incrementally, the step size shall not exceed 1% of the start and thereafter
1% of the preceding frequency value.
1% of the preceding frequency value.
8) Recording the EUT operating situation during compliance testing and decide the
EUT immunity criterion.
12.8.Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
The EUT was tested and all the test results are listed in next page.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 44 of 66
Injected Currents Susceptibility Test Results
Audix Technology (Shenzhen)Co.,Ltd.
Date : 07/26/2007
Applicant
:
Harman Multimedia DBA Harman
Motive Inc.
Motive Inc.
Test Date
:
Jul.08, 2007
EUT
:
Computer Speaker System
Temperature
:
24
℃
M/N
:
jbl on stage lll
Humidity
:
52
%
Power Supply
:
DC 12V Adaptor Input AC
230V/50Hz
230V/50Hz
Test Mode
:
Data Transmitting
Test Engineer
:
Jolly Criterion
: A
Pressure
:
100.6KPa
Frequency
Range
(MHz)
Injected Position
Voltage Level
(e.m.f.)
Criterion Result
0.15 ~ 20
AC Mains
3V(rms),
Unmodulated
A PASS
20 ~ 80
AC Mains
3V(rms),
Unmodulated
A PASS
Remark : 1. Modulation Signal:1kHz 80% AM