JBL ON STAGE III IIIP (serv.man6) EMC - CB Certificate ▷ View online
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 29 of 66
7. IMMUNITY PERFORMANCE CRITERIA DESCRIPTION
Performance Level
The test results shall be classified in terms of the loss of function or degradation of performance of the
equipment under test, relative to a performance level by its manufacturer or the requestor of the test, or the
agreed between the manufacturer and the purchaser of the product.
Definition related to the performance level:
1. Based on the used product standard
2. Based on the declaration of the manufacturer, requestor or purchaser
For EN55024
Criterion A:
Definition: normal performance within limits specified by the manufacturer, requestor and purchaser.
The equipment shall continue to operate as intended without operator intervention. No degradation of
performance or loss of function is allowed below a performance level specified by the manufacturer when
the equipment is used as intended. The performance level may be replaced by a permissible loss of
performance. If the minimum performance level or the permissible performance loss is not specified by the
manufacturer, then either of these may be derived from the product description and documentation, and by
what the user may reasonably expect from the equipment if used as intended.
Criterion B:
Definition: temporary loss of function or degradation of performance which ceases after the disturbance
ceases, and from which the equipment under test recovers its normal performance, without operator
intervention.
After the test, the equipment shall continue to operate as intended without operator intervention. No
degradation of performance or loss of function is allowed, after the application of the phenomena below a
performance level specified by the manufacturer, when the equipment is used as intended. The performance
level may be replaced by a permissible loss of performance. During the test, degradation of performance is
allowed. However, no change of operating state or stored data is allowed to persist after the test. If the
minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then
either of these may be derived from the product description and documentation, and by what the user may
reasonably expect form the equipment if used as intended.
Criterion C:
Definition: temporary loss of function or degradation of performance, the correction of which requires
operator intervention.
Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of
the controls by the user in accordance with the manufacturer’s instructions. Functions, and/or information
stored in non-volatile memory, or protected by a battery backup, shall not be lost.
Criterion D:
Definition: loss of function or degradation of performance, which is not recoverable, owing to damage to
hardware or software, or loss of data.
Criterion A:
Definition: normal performance within limits specified by the manufacturer, requestor and purchaser.
The equipment shall continue to operate as intended without operator intervention. No degradation of
performance or loss of function is allowed below a performance level specified by the manufacturer when
the equipment is used as intended. The performance level may be replaced by a permissible loss of
performance. If the minimum performance level or the permissible performance loss is not specified by the
manufacturer, then either of these may be derived from the product description and documentation, and by
what the user may reasonably expect from the equipment if used as intended.
Criterion B:
Definition: temporary loss of function or degradation of performance which ceases after the disturbance
ceases, and from which the equipment under test recovers its normal performance, without operator
intervention.
After the test, the equipment shall continue to operate as intended without operator intervention. No
degradation of performance or loss of function is allowed, after the application of the phenomena below a
performance level specified by the manufacturer, when the equipment is used as intended. The performance
level may be replaced by a permissible loss of performance. During the test, degradation of performance is
allowed. However, no change of operating state or stored data is allowed to persist after the test. If the
minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then
either of these may be derived from the product description and documentation, and by what the user may
reasonably expect form the equipment if used as intended.
Criterion C:
Definition: temporary loss of function or degradation of performance, the correction of which requires
operator intervention.
Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of
the controls by the user in accordance with the manufacturer’s instructions. Functions, and/or information
stored in non-volatile memory, or protected by a battery backup, shall not be lost.
Criterion D:
Definition: loss of function or degradation of performance, which is not recoverable, owing to damage to
hardware or software, or loss of data.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 30 of 66
8. ELECTROSTATIC DISCHARGE IMMUNITY TEST
8.1. Test Equipments
Item Equipment
Manufacturer Model No. Serial No.
Last Cal.
Cal. Interval
1. ESD Tester EM Test
Dito
V0503100053 Mar.06, 07 1 Year
8.2. Block Diagram of Test Setup
8.2.1.Block Diagram of EUT Test Setup
(EUT: Computer Speaker System)
8.2.2.Block Diagram of ESD Test Setup
(EUT: Computer Speaker System )
8.3. Test Standard
EN 55024: 1998+A1:2001+A2: 2003 (IEC 61000-4-2: 2001)
(Severity Level 3 for Air Discharge at 8kV,
Severity Level 2 for Contact Discharge at 4kV)
(Severity Level 3 for Air Discharge at 8kV,
Severity Level 2 for Contact Discharge at 4kV)
Remark: is Discharge Electrode
EUT and
Support System
AC Mains
AC Mains
ESD
Tester
0.8 m
PC
AC Mains
Keyboard
Mouse
EUT
AC Mains
Monitor
a: Audio Cable
b: USB Cable
: Core
b: USB Cable
: Core
a
Adaptor
b
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 31 of 66
8.4. Severity Levels and Performance Criterion
8.4.1. Severity level
Level Test
Voltage
Contact Discharge (kV)
Test Voltage
Air Discharge (kV)
1.
2
2
2.
4
4
3.
6
8
4.
8
15
X Special
Special
8.4.2. Performance criterion : B
8.5. EUT Configuration
The configuration of EUT are listed in Section 3.5.
8.6. Operating Condition of EUT
Same as radiated test which is listed in Section 4.6. except the test set up replaced by
Section 8.2.
Section 8.2.
8.7. Test Procedure
8.7.1. Air
Discharge:
The test was applied on non-conductive surfaces of EUT. The round discharge tip
of the discharge electrode was approached as fast as possible to touch the EUT.
After each discharge, the discharge electrode was removed from the EUT. The
generator was re-triggered for a new single discharge and repeated 20 times for
each pre-selected test point. This procedure was repeated until all the air discharge
completed
After each discharge, the discharge electrode was removed from the EUT. The
generator was re-triggered for a new single discharge and repeated 20 times for
each pre-selected test point. This procedure was repeated until all the air discharge
completed
8.7.2. Contact Discharge:
All the procedure was same as Section 8.7.1. except that the generator was
re-triggered for a new single discharge and repeated 50 times for each pre-selected
test point. the tip of the discharge electrode was touch the EUT before the
discharge switch was operated.
test point. the tip of the discharge electrode was touch the EUT before the
discharge switch was operated.
8.8. Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
The EUT was tested and all the test results are listed in next page.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 32 of 66
Electrostatic Discharge Test Results
Audix Technology (Shenzhen) Co., Ltd.
Date : 07/26/2007
Applicant
:
Harman Multimedia DBA Harman
Motive Inc.
Motive Inc.
Test Date
:
Jul.12, 2007
EUT
:
Computer Speaker System
Temperature
: 25
℃
M/N
:
jbl on stage lll
Humidity
: 55
%
Test Voltage
:
DC 12V Adaptor Input AC
230V/50Hz
230V/50Hz
Test Mode
:
Data Transmitting
Test Engineer
:
Shelle Criterion
: B
Pressure
:
100.6KPa
Air Discharge:
±
2kV
±
4kV
±
8kV # For Air Discharge each Point Positive 10 times and negative 10
times discharge.
Contact Discharge:
Contact Discharge:
±
2kV
±
4kV # For Contact Discharge each point positive 25 times and
negative 25 times discharge
Location
Kind
A-Air Discharge
C-Contact Discharge
Result
Slots 5
points
A
PASS
Ports 3
points
A
PASS
Buttons 2
points
A
PASS
USB port
1 point
C/A
PASS
Matel plane
4 points
C
PASS
HCP 4
points
C
PASS
VCP of Front
1 point
C
PASS
VCP of Rear
1 point
C
PASS
VCP of Left
1 point
C
PASS
VCP of Right
1 point
C
PASS
Test Equipment :
ESD Test dito
ESD Test dito
Discharge should be considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical Coupling
Plane (VCP).
Plane (VCP).
Click on the first or last page to see other ON STAGE III IIIP (serv.man6) service manuals if exist.