JBL ON STAGE 400P (serv.man4) EMC - CB Certificate ▷ View online
IEC 60950-1 (ed.1)
-
Page 5 of 7
-
www.nemko.com
Report No. 100711
Clause
Requirement – Test
Result - Remark
Ver-
dict
U.2.1
Replacement:
Electric strength
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V, or;
INSULATION, 3000 V, or;
- for REINFORCED INSULATION, 6000 V.
Not TIW used.
N
U.2.2
Replacement:
Flexibility and adherence
Flexibility and adherence
Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
Not TIW used.
N
Table U.1
Replacement:
Mandrel diameter
Mandrel diameter
The tension to be applied to the wire during winding on
the mandrel is calculated from the wire diameter to be
equivalent to 118 Mpa ± 10 % (118 N/mm2 ± 10 %).
Not TIW used.
N
IEC 60950-1 (ed.1)
-
Page 6 of 7
-
www.nemko.com
Report No. 100711
U.2.3
Replacement:
Replace the first paragraph with the following.
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
Not TIW used.
N
U.2.4
Replacement:
Replace the third paragraph describing the test voltage
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
Not TIW used.
N
U.3.1
Replacement:
Replace with the following.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
Not TIW used.
N
IEC 60950-1 (ed.1)
-
Page 7 of 7
-
www.nemko.com
Report No. 100711
U.3.2
Replacement:
Replace with the following.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
Not TIW used.
N
IEC 60950-1 (ed.1)
-
Page 1 of 1
-
www.nemko.com
Report No. 100711
ATTACHMENT: KOREAN DIFFERENCES
Test results according to CB BULLETIN No. 112A, December 2006
Clause
Requirements – Test
Result – Remark
Verdict
1.5.101 Addition
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
Class III equipment. No
connection to mains supply.
connection to mains supply.
N
7 Addition
EMC
The apparatus shall comply with the relevant
CISPR standards.
The apparatus shall comply with the relevant
CISPR standards.
Must be considered before
marketing in Korea.
marketing in Korea.
—
Click on the first or last page to see other ON STAGE 400P (serv.man4) service manuals if exist.