JBL ON STAGE 400P (serv.man4) EMC - CB Certificate ▷ View online
IEC 60950-1 (ed.1)
- Page 4 of 5 -
www.nemko.com
Report No. 100711
TRF No. IECEN60950_1C
The following key national differences are based on requirements other than national regulatory
requirements. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL 60950-1, First Edition)
should be consulted for further details on the national differences summarized below
requirements. The bi-national standard (CAN/CSA C22.2 No. 60950-1/UL 60950-1, First Edition)
should be consulted for further details on the national differences summarized below
1.5.1
Components of equipment must be suitable for
the application, and must comply with the
requirements of the equipment standard and the
applicable national (Canadian and/or U.S.)
component or material standards, as far as they
may apply.
the application, and must comply with the
requirements of the equipment standard and the
applicable national (Canadian and/or U.S.)
component or material standards, as far as they
may apply.
The acceptance will be based on the following:
I) A component Certified by a Canadian or U.S.
National Certification Body (NCB) to a Canadian
or U.S. component standard will be checked for
correct application and use in accordance with its
specified rating. Where necessary, it will also be
subject to the applicable tests of the equipment
standard.
National Certification Body (NCB) to a Canadian
or U.S. component standard will be checked for
correct application and use in accordance with its
specified rating. Where necessary, it will also be
subject to the applicable tests of the equipment
standard.
J) A component, which has a CB Test Certificate
for compliance with a relevant IEC component
standard, will be checked for correct application
and use in accordance with its specified ratings.
Where necessary, it will also be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
for compliance with a relevant IEC component
standard, will be checked for correct application
and use in accordance with its specified ratings.
Where necessary, it will also be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
K) A component, which has no approval as in A)
or B) above or which is used not in accordance
with its specified ratings, will be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
or B) above or which is used not in accordance
with its specified ratings, will be subject to the
applicable tests of the equipment standard, and
to the applicable tests of the Canadian and/or
U.S. component or material standard, under the
conditions occurring in the equipment.
L) Some components may require annual re-
testing, which may be carried out by the
manufacturer, CSA International or another
laboratory
testing, which may be carried out by the
manufacturer, CSA International or another
laboratory
All critical components are
certified. Refer to appended
table 1.5.1 in main CB Test
Report.
certified. Refer to appended
table 1.5.1 in main CB Test
Report.
P
2.3.1
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 Vdc, the maximum acceptable current
through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
ringing signals and with voltages exceeding 42.4
Vp or 60 Vdc, the maximum acceptable current
through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mA dc
under normal operating conditions.
No TNV circuitry.
N
IEC 60950-1 (ed.1)
- Page 5 of 5 -
www.nemko.com
Report No. 100711
TRF No. IECEN60950_1C
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible conductive
parts.
apply to SELV Circuits and accessible conductive
parts.
No TNV circuitry.
N
2.6.3.4
When subject to impedance testing, protective
earthing and bonding are required to be
subjected to the additional test conditions
specified.
earthing and bonding are required to be
subjected to the additional test conditions
specified.
Class III equipment.
N
3.2.1.2
Equipment connected to centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
Class III equipment. Equipment
not for connection to DC mains.
not for connection to DC mains.
N
4.2.8.1
Enclosures around CRT’s with a face diameter of
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk
of injury due to the implosion of the CRT.
No CRTs in the equipment.
N
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
No handles.
N
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
No TNV circuitry.
N
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
No TNV circuitry.
N
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
No TNV circuitry.
N
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
No TNV circuitry.
N
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
No TNV circuitry.
N
IEC 60950-1 (ed.1)
-
Page 1 of 1
-
www.nemko.com
Report No. 100711
TRF No. IECEN60950_1C
ATTACHMENT: CHINESE DIFFERENCES
Test results according to CB BULLETIN No. 112A, December 2006
Clause
Requirement - Test
Result - Remark
Ver-
dict
1.4.5 Supply
tolerance:
Item 1.4.5 of IEC 60950 stipulates the
tolerance of rated voltage is +6% and –10%,
while GB4943-2001 makes a specification of
tolerance of +10% and –10%.
tolerance of rated voltage is +6% and –10%,
while GB4943-2001 makes a specification of
tolerance of +10% and –10%.
Class III equipment.
N
1.7.1
Power rating marking:
Item 1.7.1 of IEC 60950 does not specify
concrete figures of markings for supply voltage
and frequency, instead, descriprions are give
by examples. But the examples do not include
Chinas`s mains voltage.
GB4943-2001 stiplulates that:
- A single rated voltage shall be expressed as
220V
- When a rated volrage range is given, the
range shall cover 220V
- When a variety of rated voltages or rated
voltage ranges are given, one of them shall be
220V, and shall be set as 220V when
dispatched from the factory
- Rated frequency or rated frequency range
shall be 50Hz or include 50Hz
- If a unit is not provided with a means of direct
connection to the a.c. mains supply, it need not
be marked with any electrical rating
Item 1.7.1 of IEC 60950 does not specify
concrete figures of markings for supply voltage
and frequency, instead, descriprions are give
by examples. But the examples do not include
Chinas`s mains voltage.
GB4943-2001 stiplulates that:
- A single rated voltage shall be expressed as
220V
- When a rated volrage range is given, the
range shall cover 220V
- When a variety of rated voltages or rated
voltage ranges are given, one of them shall be
220V, and shall be set as 220V when
dispatched from the factory
- Rated frequency or rated frequency range
shall be 50Hz or include 50Hz
- If a unit is not provided with a means of direct
connection to the a.c. mains supply, it need not
be marked with any electrical rating
Class III equipment.
N
1.7.12
Plate and warning marking in Chinese:
Item 1.7.12 of GB4943-2001 stipulates;
instructions and equipment markings related to
safety shall be in simplified Chinese
Item 1.7.12 of GB4943-2001 stipulates;
instructions and equipment markings related to
safety shall be in simplified Chinese
Must be considered before
marketing in China.
marketing in China.
—
3.2.1
Power supply plug:
According to China`s particular standards for
power supply plug, it is added in article 3.2.1 of
GB4943-2001 that plug connecting equipment
with a.c. mains supply shall be in accordance
with requirements of GB1002
According to China`s particular standards for
power supply plug, it is added in article 3.2.1 of
GB4943-2001 that plug connecting equipment
with a.c. mains supply shall be in accordance
with requirements of GB1002
Class III equipment.
N
IEC 60950-1 (ed.1)
- Page 1 of 1 -
www.nemko.com
Report No. 100711
ATTACHMENT: ISRAELI DIFFERENCES
to IEC 60950-1 (ed.1)
Clause
Requirements – Test
Result – Remark
Verdict
1.7.0
Marking and Instructions
The package of the equipment shall be marked in
Hebrew, and shall include:
- The name of the product,
- The name of the manufacturer,
- The country of production,
- The name and the address of the importer.
The marking shall be on a rectangular label (of at
least 52mm x 24mm). The letters height should be
at least 2mm. The color of the label shall be in
contrast to the color of the package.
The package of the equipment shall be marked in
Hebrew, and shall include:
- The name of the product,
- The name of the manufacturer,
- The country of production,
- The name and the address of the importer.
The marking shall be on a rectangular label (of at
least 52mm x 24mm). The letters height should be
at least 2mm. The color of the label shall be in
contrast to the color of the package.
Must be considered before
marketing in Israel.
marketing in Israel.
—
1.7.12 Language
All instructions and warnings concerning safety
should be in the Hebrew language as well.
Must be considered before
marketing in Israel.
marketing in Israel.
—
2.101 EMC
The equipment shall comply with SI 961 part 6
(CISPR 22 + 24).
Class III equipment.
N
3.2.1.1
Connection to an a.c. mains supply
Additional note:
In Israel the mains supply plug shall comply with
Israeli standard SI 32.
Additional note:
In Israel the mains supply plug shall comply with
Israeli standard SI 32.
Class III equipment. Not for
permanently connected to the
mains.
permanently connected to the
mains.
N
Click on the first or last page to see other ON STAGE 400P (serv.man4) service manuals if exist.