JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Page 97 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.6.3.4
When subject to impedance testing, protective
earthing and bonding are required to be
subjected to the additional test conditions
specified.
earthing and bonding are required to be
subjected to the additional test conditions
specified.
Class II equipment
N/A
3.2.1.2
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the mains protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the mains protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
N/A
4.2.8.1
Enclosures around CRTs with a face diameter of
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
No such devices within the EUT
N/A
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
No such devices within the EUT
N/A
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current measurement
tests.
telecommunication ringing signals is required to
comply with a special touch current measurement
tests.
No TNV circuit within the EUT
N/A
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subject to special
investigation.
electrical separation unless subject to special
investigation.
N/A
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
N/A
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipmentis subject to special
installation and performance restrictions.
permitted if the equipmentis subject to special
installation and performance restrictions.
No TNV circuit within the EUT
N/A
Page 98 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
National Differences Korea (KR)
IEC 60950-1, 1st ed.
1.5.101 Addition
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
P
7 Addition
EMC
The apparatus shall comply with the relevant
CISPR standards.
CISPR standards.
P
Page 99 of 99
ST-06153
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
National Differences
Argentine (AR), China (CN) and Singapore (SG)
IEC 60950-1, 1st ed.
No national differences.
P
Appendix 1
Page 1 of 6
ST- 06153
Equipment’s combined with two-pole plug (Class II)
Supplementary tests on plug portion according to EN 50075
Supplementary tests on plug portion according to EN 50075
7 DIMENSIONS
Checking dimensions by measuring and by
gauges according to Standard Sheet 1.
gauges according to Standard Sheet 1.
Complied P
8
PROTECTION AGAINST ELECTRIC SHOCK
8.1 Finger
test:
Shown as figure 3.
Ambient temperature: 35 ± 2 °C.
Ambient temperature: 35 ± 2 °C.
Force: 75
N, 60
s.
After subjected for 60 s with a
force of 75 N, no impair
occurred, and no live parts
accessible
force of 75 N, no impair
occurred, and no live parts
accessible
P
8.2
Single pin insertion test:
Checked by gauge of figure 4 (1 kg).
Ambient temperature: 35 ± 2 °C.
Ambient temperature: 35 ± 2 °C.
60
s.
The gauge did not come into
contact with the engagement
face of the plug
contact with the engagement
face of the plug
P
8.3
External parts of insulating material
Complied
P
9 CONSTRUCTION
9.3
Pins of plug solid
Complied (see clause 13)
P
9.4
Pins of plug locked against rotation
Complied
(see clauses 13.1 and 13.4)
(see clauses 13.1 and 13.4)
P
9.5
Effective permanent connections:
- soldered, welded, crimped
Soldered connection provided
P
- screwed and snap-on connections not used
Complied
P
- presoldered flexible conductor for crimping not
permitted
permitted
P
10
RESISTANCE TO HUMIDITY
Humidity
conditioning
P
Humidity
(%) .......................................................: 95
Temperature (
°C) ...............................................: 30
Test
time (h) ....................................................... : 48
Click on the first or last page to see other ON CALL (serv.man2) service manuals if exist.