DOWNLOAD JBL ON CALL (serv.man2) Service Manual ↓ Size: 1.63 MB | Pages: 127 in PDF or view online for FREE

Model
ON CALL (serv.man2)
Pages
127
Size
1.63 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
Appendix 1 
Page 2 of 6 
ST- 06153 
 
 
 
 
 
11 
INSULATION RESISTANCE AND ELECTRIC STRENGTH 
 
11.1 
Insulation resistance test: d.c. 500 V, applied for 
60
 s. The insulation resistance shall be more 
than 5 M
Ω. 
 P 
11.2 
Electric strength test: a.c. 2000 V, 50 Hz, applied 
for 1 min. 
After the test, no flashover or 
breakdown occurred  
 
13 MECHANICAL 
STRENGTH 
 
13.1 Compression 
test: 
150 N, 5 min. (shown as figure 7)  
No deformation or any undue 
change of dimensions 
13.2 
Torque test on pins: 0.4 Nm, 1 min 
No pin turn occurred 
13.3 
Abrasion test:  
20 000 movements (fixed as figure 9) 
No damage 
13.4 
Pull test with steel plate on pin:  
Heated for 70 °C 
± 2 °C, 60  min; pull force 
40
 N, 60
 s. Displacement of the pin can not 
be more than 1 mm 
After the test, no pin 
displacement occurred 
 
14 
RESISTANCE TO HEAT AND TO AGEING 
 
14.1.1 
Heating test: 100 °C 
± 2 °C, 1 hour 
No damage 
14.1.2 
Compression test: 80 °C 
± 2 °C, force 20 N, 
60
 min 
No damage 
14.2 Aging 
test: 
70 °C 
± 2 °C, 168 hours; And then removed to 
room temperature for 96 hours 
No cracks visible 
 
Forefinger wrap in a dry piece of rough cloth and 
press the plug  with a force of 5 N 
No traces 
 
 
Appendix 1 
Page 3 of 6 
ST- 06153 
 
 
 
 
 
15 
CURRENT-CARRYING PARTS AND CONNECTIONS 
 
15.1 
Connections withstand the mechanical stresses 
occurring in normal use 
Complied P 
15.2 
Contact pressure not transmitted through 
insulating material 
 P 
15.3 
Material of current-carrying parts 
> 58% copper 
 
17 
RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT AND TO 
FIRE 
 
 Glow-wire 
test: 
750 °C for parts necessary to retain current-
carrying parts in position; 650 °C for other parts 
Flames and glowing 
extinguished within 30 s 
 
 
Appendix 1 
Page 4 of 6 
ST- 06153 
 
 
 
 
 
Supplementary tests on plug portion according to EN 50075 or IEC 60884-1 
 
 
Requirement - Test 
References to 
clauses in 
Result-Remark 
Comply 
 
 
IEC 
60884-1
EN 50075  
 
1 
Plug portion 
 
 
 
 
 
CEE 7 Standard Sheet 
 
 
XVI P 
 
EN 50075 
 
 
 P 
2 
Dimensions 
 
 
 
 
 
Checking dimensions by measuring 
and by gauges according to 
Standard sheet 
 
 
 P 
 
The edges of the metal-pins, 
Chamfered or rounded off? 
 
 
 P 
3 
Protection against electric 
shock
 
 
 
 
 
a 
Test finger (75 N, 1 min. in 35 °C) 
10.1 
8.1 
 
 or 
 
 
 
 
 
Applicable appliance standard 
 
 
 
 
b 
Single pole insertion. Checked with 
gauge: 
 
 
 
 
 Figure 
 
8.2 
 
 or 
 
 
 
 
 
C19A or C19B (CEE 7) 
9.2 
 
 
c 
Compression test 150 N, 5 min. 
10.1 
13.1 
 
d 
External parts made of insulating 
material 
10.4 8.3 
 
4 
Construction 
 
 
 
 
a 
Test on pins which are not solid 
14.2 
9.3 
 
b 
Pins shall be locked against 
rotation 0.4 Nm 1 min. 
24.2 13.2 
 
 
 
c 
Pins shall be adequately fixed in 
the body 1 min. Temperature 70 °C 
40 N for plugs < 2,5 A 
50 N for plugs > 2,5 A 
24.10 13.4 
 
 
 
 
Appendix 1 
Page 5 of 6 
ST- 06153 
 
 
 
 
 
 
Requirement - Test 
References to 
clauses in 
Result-Remark 
Comply 
 
 
IEC 
60884-1
EN 50075  
 
d 
Pins of copper or copper alloy min. 
58 % copper or equivalent 
26.5-26.6
15.3 
> 58 % copper 
e 
Plug shall not impose undue strain 
on fixed socket-outlets, 0,25 Nm 
14.23.2  
 
Measured max. 
0.07 Nm 
 
f 
Abrasion test on the insulating 
sleeves 20000 movements 
24.7 13.3 
 
 
 
5 
Resistance of insulating 
material to abnormal heat, to 
fire and to tracking
 
 
 
 
 
a 
Compression test 1 h in 80 °C 
25.4 
14.1.2 
 
 
b 
Glow-wire test 750 °C 
26.1.1 
17 
 
 
 
c 
Resistance to tracking 175 V 
(other than ordinary) 
28.2  
 
 
 
N/A 
 
P - Pass; N/A - Not applicable 
 
Page of 127
Display

Click on the first or last page to see other ON CALL (serv.man2) service manuals if exist.