DOWNLOAD JBL ON CALL (serv.man2) Service Manual ↓ Size: 1.63 MB | Pages: 127 in PDF or view online for FREE

Model
ON CALL (serv.man2)
Pages
127
Size
1.63 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-call-sm2.pdf
Date

JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
Appendix 4 
Page 2 of 3 
ST-06153 
 
 
 
 
 
J2.2.6.2 
High voltage test 
Clause 2.13.2 items (a) and (c), test voltage see 
table 2.3; 
Clause 2.13.2 items (b) and (d), test voltage is 
3500 Vac, 1 min.; 
Clause 2.13.2 item (e), test voltage is 1250 Vac, 
1 min. 
 P 
J2.2.6.3 
Mechanical strength of pin tests 
 
J2.2.6.3.1  Tumbling barrel test 
Three samples tests:  
EUT mass 
≤ 250 g, 500 times drops; 
EUT mass 
> 250 g, 250 times drops. 
500 times drops 
J2.2.6.3.2  Pin bending test 
Three sample plugs tested for 20 movement 
cycles.  
 P 
J2.2.6.4 Temperature 
rise 
test 
The temperature rise of the pins shall not exceed 
45 K. 
 P 
J2.2.6.5 
Securement of pins of the plug portion 
 
 
Movement of pins:  
Preconditioned for 40 
± 1 °C, 1 h;  
Test force applied 18 
± 1 N-push. 
 P 
 
Fixing of pins:  
Heated for 50 
± 2 °C, 1 h; 
Test force applied 60 
± 0.6 N-push/pull, 10 min. 
 P 
J2.2.6.6 
Tests on the insulation material of insulated pin plug portions 
 
 General 
 
Info 
 
Pressure test at high temperature:  
160 
± 5 °C for 2 h, 2.5 N. 
 P 
 
 
 
Appendix 4 
Page 3 of 3 
ST-06153 
 
 
 
 
 
 
Static damp heat test:  
Db (12 + 12 h cycle), 95 % R.H., lower 
temperature 25 
± 3 °C and upper temperature 40 
°C. After the test, It shall be complied with  
clause 2.13.2 (e) insulation resistance test,  
clause 2.13.3 high voltage test, and  
clause 2.13.13.6 abrasion test 
 P 
 
Lower temperature test:  
−15 ± 2 °C for 24 h. After the test, It shall be 
complied with  
clause 2.13.2 (e) insulation resistance test,  
clause 2.13.3 high voltage test, and  
clause 2.13.13.6 abrasion test 
 P 
 
Impact test at low temperature:  
−15 ± 2 °C for 24 h, falling weight mass 100 ± 1 
g, falling height 100 mm, four impacts. 
 P 
 Abrasion 
test: 
4 N, 10 000 times in each direction (20 000 
movements) at a rate of 30 movements per 
minute. 
 P 
J2.2.6.7 
Torque to socket-outlet test 
Plug shall not impose undue strain on fixed 
socket-outlets, limit 
≤ 0.25 Nm 
Measured max. 0.06 Nm 
P - Pass; N/A - Not applicable; Info - Information only
 
 
 
Appendix 5 
Page 1 of 1 
ST-06153 
 
 
 
 
 
Equipment’s combined with China plug. 
Supplementary tests on plug portion according to IEC 61558-1 
 
 
Requirement - Test 
Result-Remark 
Comply 
 
 
 
 
1 
Dimensions 
 
 
 
Checked according to Fig 1 of GB 
1002-1996 
 P 
2 
Mechanical strength (Clause 16 
of IEC 61558-1)
 
 
 
2.1 
Drop Test (16.3) 
100 falls 
2.2 
Tumbling Barrel Test (a of 16.4)  
50 falls 
2.3 
Torque Test (b of 16.4) 
0.4 Nm, 1 min for each direction 
2.4 
Pull Test (c of 16.4) 
40 N, 1 min (70
°C) P 
P - Pass; N/A - Not applicable
 
 
 
Appendix 6 
Page 1 of 1 
ST-06153 
 
 
 
 
 
Equipment’s combined with two-pole plug (Class II) 
Supplementary tests on plug portion are according to ANSI/UL 1310 
 
Clause  Requirement - Test 
Result-Remark 
Comply 
 
 
 
 
1 Dimensions 
 
1.1 
Checked according to figure C1.1 of ANSI/UL 
1681 
 P 
1.2 
Checked according to figure 5.1, sub-clauses 
5.11, 5.12 and 5.13 of ANSI/UL 1310-1996  
 P 
Direct Plug-In Blade Secureness Test 
 
2.1 
Pull test (89 N / 20 lb, 2 min.); clause 41 of 
ANSI/UL 1310-1996 
Blades are not loosened 
Direct Plug-In Security of Input Contacts Test 
 
3.1 
Push test of each blade (133 N / 30 lb, 1 
min.); clause 42 of ANSI/UL 1310-1996 
Blades are not loosened 
3.2 
Push test of all blades (178 N / 40 lb, 1 min.); 
clause 42 of ANSI/UL 1310-1996 
Blades are not loosened 
Rod Pressure on Direct Plug-in Units 
 
4.1 
Outer surface of the unit rod pressure test (89N / 20lb, 1 min); sub-clause 
44.4 of ANSI/UL 1310-1996  
 
Live part shall not become user accessible 
 
 
Hazardous part shall not become user 
accessible 
 P 
 
Voltage between dead metal and earth 
ground shall not exceed 42.4 Vpeak..............:
 N/A 
 
Leakage between dead metal and earth 
ground shall not exceed 7.07 mApeak...........:
 N/A 
Resistance to Crushing on Direct Plug-in Units 
 
5.1 
Enclosure crushing test (334 N / 75 lb, 1 
min.); sub-clause 44.5 of ANSI/UL 1310-1996
There is no shattering, 
cracking or other damage to 
the enclosure that will 
expose internal wiring or live 
parts 
P - Pass; N/A - Not applicable 
 
Page of 127
Display