JBL ON CALL (serv.man2) EMC - CB Certificate ▷ View online
Appendix 4
Page 2 of 3
ST-06153
J2.2.6.2
High voltage test
Clause 2.13.2 items (a) and (c), test voltage see
table 2.3;
table 2.3;
Clause 2.13.2 items (b) and (d), test voltage is
3500 Vac, 1 min.;
3500 Vac, 1 min.;
Clause 2.13.2 item (e), test voltage is 1250 Vac,
1 min.
1 min.
P
J2.2.6.3
Mechanical strength of pin tests
J2.2.6.3.1 Tumbling barrel test
Three samples tests:
EUT mass
≤ 250 g, 500 times drops;
EUT mass
> 250 g, 250 times drops.
500 times drops
P
J2.2.6.3.2 Pin bending test
Three sample plugs tested for 20 movement
cycles.
cycles.
P
J2.2.6.4 Temperature
rise
test
The temperature rise of the pins shall not exceed
45 K.
45 K.
P
J2.2.6.5
Securement of pins of the plug portion
P
Movement of pins:
Preconditioned for 40
± 1 °C, 1 h;
Test force applied 18
± 1 N-push.
P
Fixing of pins:
Heated for 50
± 2 °C, 1 h;
Test force applied 60
± 0.6 N-push/pull, 10 min.
P
J2.2.6.6
Tests on the insulation material of insulated pin plug portions
General
Info
Pressure test at high temperature:
160
± 5 °C for 2 h, 2.5 N.
P
Appendix 4
Page 3 of 3
ST-06153
Static damp heat test:
Db (12 + 12 h cycle), 95 % R.H., lower
temperature 25
temperature 25
± 3 °C and upper temperature 40
°C. After the test, It shall be complied with
clause 2.13.2 (e) insulation resistance test,
clause 2.13.3 high voltage test, and
clause 2.13.13.6 abrasion test
P
Lower temperature test:
−15 ± 2 °C for 24 h. After the test, It shall be
complied with
complied with
clause 2.13.2 (e) insulation resistance test,
clause 2.13.3 high voltage test, and
clause 2.13.13.6 abrasion test
P
Impact test at low temperature:
−15 ± 2 °C for 24 h, falling weight mass 100 ± 1
g, falling height 100 mm, four impacts.
g, falling height 100 mm, four impacts.
P
Abrasion
test:
4 N, 10 000 times in each direction (20 000
movements) at a rate of 30 movements per
minute.
movements) at a rate of 30 movements per
minute.
P
J2.2.6.7
Torque to socket-outlet test
Plug shall not impose undue strain on fixed
socket-outlets, limit
socket-outlets, limit
≤ 0.25 Nm
Measured max. 0.06 Nm
P
P - Pass; N/A - Not applicable; Info - Information only
Appendix 5
Page 1 of 1
ST-06153
Equipment’s combined with China plug.
Supplementary tests on plug portion according to IEC 61558-1
Supplementary tests on plug portion according to IEC 61558-1
Requirement - Test
Result-Remark
Comply
1
Dimensions
Checked according to Fig 1 of GB
1002-1996
1002-1996
P
2
Mechanical strength (Clause 16
of IEC 61558-1)
of IEC 61558-1)
2.1
Drop Test (16.3)
100 falls
P
2.2
Tumbling Barrel Test (a of 16.4)
50 falls
P
2.3
Torque Test (b of 16.4)
0.4 Nm, 1 min for each direction
P
2.4
Pull Test (c of 16.4)
40 N, 1 min (70
°C) P
P - Pass; N/A - Not applicable
Appendix 6
Page 1 of 1
ST-06153
Equipment’s combined with two-pole plug (Class II)
Supplementary tests on plug portion are according to ANSI/UL 1310
Supplementary tests on plug portion are according to ANSI/UL 1310
Clause Requirement - Test
Result-Remark
Comply
1 Dimensions
1.1
Checked according to figure C1.1 of ANSI/UL
1681
1681
P
1.2
Checked according to figure 5.1, sub-clauses
5.11, 5.12 and 5.13 of ANSI/UL 1310-1996
5.11, 5.12 and 5.13 of ANSI/UL 1310-1996
P
2
Direct Plug-In Blade Secureness Test
2.1
Pull test (89 N / 20 lb, 2 min.); clause 41 of
ANSI/UL 1310-1996
ANSI/UL 1310-1996
Blades are not loosened
P
3
Direct Plug-In Security of Input Contacts Test
3.1
Push test of each blade (133 N / 30 lb, 1
min.); clause 42 of ANSI/UL 1310-1996
min.); clause 42 of ANSI/UL 1310-1996
Blades are not loosened
P
3.2
Push test of all blades (178 N / 40 lb, 1 min.);
clause 42 of ANSI/UL 1310-1996
clause 42 of ANSI/UL 1310-1996
Blades are not loosened
P
4
Rod Pressure on Direct Plug-in Units
4.1
Outer surface of the unit rod pressure test (89N / 20lb, 1 min); sub-clause
44.4 of ANSI/UL 1310-1996
44.4 of ANSI/UL 1310-1996
P
Live part shall not become user accessible
P
Hazardous part shall not become user
accessible
accessible
P
Voltage between dead metal and earth
ground shall not exceed 42.4 Vpeak..............:
ground shall not exceed 42.4 Vpeak..............:
N/A
Leakage between dead metal and earth
ground shall not exceed 7.07 mApeak...........:
ground shall not exceed 7.07 mApeak...........:
N/A
5
Resistance to Crushing on Direct Plug-in Units
5.1
Enclosure crushing test (334 N / 75 lb, 1
min.); sub-clause 44.5 of ANSI/UL 1310-1996
min.); sub-clause 44.5 of ANSI/UL 1310-1996
There is no shattering,
cracking or other damage to
the enclosure that will
expose internal wiring or live
parts
cracking or other damage to
the enclosure that will
expose internal wiring or live
parts
P
P - Pass; N/A - Not applicable