Page 16 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm)  .................................................................. :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
No mains connection
N/A
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c.
equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1
General requirements
Considered.
P
3.5.2
Types of interconnection circuits  ......................... :  Interconnection circuits of
SELV only
P
3.5.3
ELV circuits as interconnection circuits
No ELV interconnection
circuits.
N/A
3.5.4
Data ports for additional equipment
Class III equipment.
N/A
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
N/A
Angle of 10
EUT < 7kg
N/A
Test force (N)  ..................................................... : Equipment is not a
floorstanding unit.
N/A
4.2
Mechanical strength
N/A
4.2.1
General
Class III equipment, no
hazardous parts inside.
N/A
4.2.2
Steady force test, 10 N
Class III equipment, no
hazardous parts inside.
N/A
Page 17 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
4.2.3
Steady force test, 30 N
Class III equipment, no
hazardous parts inside.
N/A
4.2.4
Steady force test, 250 N
Class III equipment, no
hazardous parts inside.
N/A
4.2.5
Impact test
N/A
Fall test
Class III equipment, SELV
circuit only.
N/A
Swing test
Class III equipment, SELV
circuit only.
N/A
4.2.6
Drop test; height (mm)  ........................................ : Drop test not applicable.
N/A
4.2.7
Stress relief test
Class III equipment.
N/A
4.2.8
Cathode ray tubes
No cathode ray tube.
N/A
Picture tube separately certified .......................... :
4.2.9
High pressure lamps
No high pressure lamp.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N)  ..... :
Not wall or ceiling mounted
equipment.
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) ............ : 
No handles or manual
controls.
N/A
4.3.3
Adjustable controls
No control devices.
N/A
4.3.4
Securing of parts
Class III equipment.
N/A
4.3.5
Connection by plugs and sockets
SELV connectors do not
comply with IEC 60320 or
IEC 60083.
P
4.3.6
Direct plug-in equipment
Not intended to plug directly
into a wall socket-outlet.
N/A
Torque  ............................................................... :
Compliance with the relevant mains plug standard
 ...........................................................................  :
4.3.7
Heating elements in earthed equipment
No heating elements.
N/A
4.3.8
Batteries
Only button cell battery
provided for remote control
P
- Overcharging of a rechargeable battery
No such battery
N/A
- Unintentional charging of a non-rechargeable
battery
N/A
- Reverse charging of a rechargeable battery
N/A
- Excessive discharging rate for any battery
N/A
4.3.9
Oil and grease
No oil and grease.
N/A
Page 18 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
4.3.10
Dust, powders, liquids and gases
The equipment does not
generate ionizing radiation
or use a laser, and does not
contain flammable liquids or
gases.
N/A
4.3.11
Containers for liquids or gases
No containers for liquids or
gases in the equipment.
N/A
4.3.12
Flammable liquids  ............................................. :  The equipment does not
contain flammable liquid.
N/A
Quantity of liquid (l)  ........................................... :
Flash point ( C)  ................................................. :
4.3.13
Radiation
No ionizing radiation, laser
or flammable gases
presents.
N/A
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
Measured radiation (pA/kg)  ................................ :
Measured high-voltage (kV)  ............................... :
Measured focus voltage (kV)  ............................. :
CRT markings  ................................................... :
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification  ...................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation  .... :
N/A
4.3.13.5
Laser (including LEDs)
N/A
Laser class  ........................................................ :
4.3.13.6
Other types  ........................................................ :
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No hazardous moving parts
N/A
4.4.2
Protection in operator access areas  ................... :
N/A
4.4.3
Protection in restricted access locations  ............ :
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
P
4.5.1
General
No exceeding temperature.
P
4.5.2
Temperature tests
(see appended table 4.5).
P
Normal load condition per Annex L  .................... :
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
Page 19 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
4.5.5
Resistance to abnormal heat  ............................. :  No thermoplastic parts
carrying hazardous
voltages.
N/A
4.6
Openings in enclosures
N/A
4.6.1
Top and side openings
No openings, no hazard
N/A
Dimensions (mm)  .............................................. :
4.6.2
Bottoms of fire enclosures
No fire enclosure
N/A
Construction of the bottomm, dimensions (mm)  . :
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm)  .............................................. :
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature ( C), time (weeks) ...... :
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame 
Method 1 is used.
P
Method 1, selection and application of components
wiring and materials
Equipment is class III
equipment, powered by
separately certified LPS
adaptor
P
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
Refer to  cl. 4.7.2.2
N/A
4.7.2.2
Parts not requiring a fire enclosure
Fire enclosure is not
required, class III equipment
supplied by Limited Power
Source. Components
mounted on material of min.
V-1 material.
P
4.7.3
Materials
P
4.7.3.1
General
Components and materials
have adequate flammability
classification. (see
appended table 1.5.1)
P
4.7.3.2
Materials for fire enclosures
Fire enclosure is not
required, class III equipment
supplied by Limited Power
Source. Components
mounted on material of min.
V-1 material.
N/A
Page of 82