Page 28 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)
N/A
X.1
Determination of maximum input current
N/A
X.2
Overload test procedure
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus ................................................... :
N/A
Y.2
Mounting of test samples  ................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus  ................. :
N/A
Y.4
Xenon-arc light exposure apparatus  ................... :
N/A
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
N/A
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N/A
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
Page 29 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
EN 60950-1:2006 – CENELEC COMMON MODIFICATIONS
Contents
Add the following annexes:
Annex ZA (normative)
Normative references to international
Annex ZB (normative)
Special national conditions
Annex ZC (informative)   A-deviations
P
General
Delete all the “country” notes in the reference document according to the
following list:
1.4.8  Note 
2
1.5.1
Note 2 & 3
1.5.7.1 Note
1.5.8  Note 
2
1.5.9.4  Note
1.7.2.1 
Note 4, 5 & 6
2.2.3  Note
2.2.4
Note
2.3.2
Note
2.3.2.1  Note 2
2.3.4
Note 2
2.6.3.3   Note 2 & 3
2.7.1  Note
2.10.3.2   Note 2
2.10.5.13  Note 3
3.2.1.1  Note
3.2.4
Note 3.
2.5.1
Note 2
4.3.6   Note 1 & 2
4.7
Note 4
4.7.2.2  Note
4.7.3.1  Note 2
5.1.7.1   Note 3 & 4
5.3.7
Note 1
6
Note 2 & 5
6.1.2.1   Note 2
6.1.2.2  Note
6.2.2   Note 6.
2.2.1
Note 2
6.2.2.2  Note
7.1
Note 3
7.2
Note
7.3
Note 1 & 2
G.2.1   Note 2
Annex H  Note 2
P
1.3.Z1
Add the following subclause:
1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed as to present no danger
when used for its intended purpose, either in normal operating conditions or
under fault conditions, particularly providing protection against exposure to
excessive sound pressures from headphones or earphones.
NOTE Z1 A new method of measurement is described in EN 50332-1, Sound system
equipment:
Headphones and earphones associated with portable audio equipment - Maximum sound
pressure level measurement methodology and limit considerations - Part 1: General
method for “one package equipment”, and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with portable audio equipment - Maximum sound
pressure level measurement methodology and limit considerations - Part 2: Guidelines to
associate sets with headphones coming from different manufacturers.
N/A
1.5.1
Add the following NOTE:
NOTE Z1 The use of certain substances in electrical and electronic equipment is
restricted within the EU: see Directive 2002/95/EC
N/A
1.7.2.1
Add the following NOTE:
NOTE Z1 In addition, the instructions shall include, as far as applicable, a warning that
excessive sound pressure from earphones and headphones can cause hearing loss
N/A
Page 30 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-circuits and earth faults in PRIMARY
CIRCUITS, protective devices shall be included either as integral parts of the
equipment or as parts of the building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective devices necessary to comply with
the requirements of 5.3 shall be included as parts of the equipment;
b) for components in series with the mains input to the equipment such as the
supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault
protection may be provided by protective devices in the building installation;
c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY
CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit
protection in the building installation, provided that the means of protection, e.g.
fuses or circuit breakers, is fully specified in the installation instructions.
If reliance is placed on protection in the building installation, the installation
instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A
the building installation shall be regarded as providing protection in accordance
with the rating of the wall socket outlet.
N/A
2.7.2
This subclause has been declared ‘void’.
N/A
3.2.3
Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in
parentheses.
N/A
3.2.5.1
Replace  
“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”.
In Table 3B, replace the first four lines by the following:
| Up to and including 6
|
0,75
a)
|
| Over 6 up to and including 10  |
(0,75)
b)
1,0
|
| Over 10 up to and including 16  |
(1,0)
c)
1,5
|
In the conditions applicable to Table 3B delete the words “in some countries” in
condition
a)
.
In NOTE 1, applicable to Table 3B, delete the second sentence.
N/A
3.3.4
In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace
with the following:
| Over 10 up to and including 16  |
1,5 to 2,5   |
1,5 to 4
|
Delete the fifth line: conductor sizes for 13 to 16 A.
N/A
4.3.13.6
Add the following NOTE:
NOTE Z1 Attention is drawn to 1999/519/EC: Council Recommendation on the limitation
of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this Recommendation which demonstrate compliance with the
applicable EU Directive are indicated in the OJEC.
N/A
Page 31 of 39
Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
Annex H
Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the
dose rate shall not exceed 1  Sv/h (0,1 mR/h) (see NOTE). Account is taken of
the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete NOTE 2.
N/A
Biblio-
graphy
Additional EN standards.
ZA
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH
THEIR CORRESPONDING EUROPEAN PUBLICATIONS
ZB
SPECIAL NATIONAL CONDITIONS
P
1.2.4.1
In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided
with a plug not establishing earthing conditions when inserted into Danish socket-
outlets.
N/A
1.5.7.1
In FinlandNorway and Sweden, resistors bridging BASIC INSULATION in
CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.2.
N/A
1.5.8
In Norway, due to the IT power system used (see annex V, Figure V.7),
capacitors are required to be rated for the applicable line-to-line voltage (230 V).
N/A
1.5.9.4
In FinlandNorway and Sweden, the third dashed sentence is applicable only
to equipment as defined in 6.1.2.2 of this annex.
N/A
1.7.2.1
In FinlandNorway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a network shall, if safety relies on
connection to protective earth or if surge suppressors are connected between the
network terminals and accessible parts, have a marking stating that the
equipment must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follows:
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
N/A
1.7.5
In Denmark, socket-outlets for providing power to other equipment shall be in
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet shall be in accordance with
Standard Sheet DK 1-1b or DK 1-5a.
N/A
2.2.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.3.2
In FinlandNorway and Sweden there are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.3.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.6.3.3
In the United Kingdom, the current rating of the circuit shall be taken as 13 A,
not 16 A.
N/A