DOWNLOAD JBL ON BEAT RUMBLE Service Manual ↓ Size: 1.85 MB | Pages: 116 in PDF or view online for FREE

Model
ON BEAT RUMBLE
Pages
116
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-beat-rumble.pdf
Date

JBL ON BEAT RUMBLE EMC - CB Certificate ▷ View online

Issue Date: 
2013-01-09 
Page 35 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
3.4.2 
 
            Separate motor control device(s) required 
for cord-connected equipment rated more than 12 
A, or with motor rated more than 1/3 hp or more 
than 120 V. 
           
 
             
           
N/A 
3.4.8 
 
            Vertically mounted disconnect devices 
oriented so up position of handle is "on". 
           
 
             
           
N/A 
3.4.11 
 
            For computer-room applications, equipment 
with battery systems capable of supplying 750 VA 
for 5 min require battery disconnect means. 
           
 
             
           
N/A 
4.2.8.1 
 
            Special opening restrictions for enclosures 
around CRTs with face dimension of 160 mm or 
more. 
           
 
             
           
N/A 
4.2.9 
 
            Compartment housing high-pressure lamp 
marked to indicate risk of explosion. 
           
 
             
           
N/A 
4.2.11 
 
            For equipment intended for mounting on 
racks and provided with slide/rails allowing the 
equipment to slide away from the rack for 
installation, service and maintenance, additional 
construction, performance and marking 
requirements are applicable to determine the 
adequacy of the slide/rails. 
           
 
             
           
N/A 
4.3.2 
 
            Loading test for equipment with handle(s) 
used to support more than 9 kg tested at four times 
the weight of the unit. 
           
 
             
           
N/A 
4.3.6 
 
            In addition to the IEC requirements, Direct 
Plug-in Equipment complies with UL 1310 or CSA 
223 mechanical assembly requirements. 
           
 
             
           
N/A 
4.3.12 
 
 
N/A 
Issue Date: 
2013-01-09 
Page 36 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
            The maximum quantity of flammable liquid 
stored in equipment complies with ANSI/NFPA 
30(Table NAE.6). 
           
             
           
4.3.12 
 
            Equipment using replenishable liquids 
marked to indicate type of liquid to be used. 
           
 
             
           
N/A 
4.3.13.2 
 
            Equipment that produces x-radiation and 
does not comply with 4.3.12 under all conditions of 
servicing marked to indicate the presence of 
radiation where readily visible. 
           
 
             
           
N/A 
4.3.13.5 
 
            Requirements contained in the applicable 
national codes and regulations apply to lasers (21 
CFR 1040 and REDR C1370). 
           
 
             
           
N/A 
4.7 
 
            Automated information storage equipment 
intended to contain more than 0.76 m³ of 
combustible media requires provision for automatic 
sprinklers or a gaseous agent extinguishing 
system. 
           
 
             
           
N/A 
4.7.3.1 
 
            Equipment for use in environmental air 
space other than ducts or plenums provided with 
metal enclosure or with non-metallic enclosure 
having adequate fire-resistance and low smoke 
producing characteristics.  Low smoke-producing 
characteristics evaluated according to UL 2043.  
Equipment for installation in space used for 
environmental air as described in Sec. 300-22(c) of 
the NEC provided with instructions indicating 
suitability for installation in such locations. 
           
 
             
           
N/A 
4.7.3.1 
 
            Flame spread rating for external surface of 
combustible material with exposed area greater 
than 0.93 m² or a single dimension greater than 1.8 
m; 50 or less for computer room applications or 
200 or less for other applications. 
           
 
             
           
N/A 
Issue Date: 
2013-01-09 
Page 37 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
4.7.3.4 
 
            Wire marked "VW-1" or "FT-1" considered 
equivalent. 
           
 
             
           
Pass 
5.1.8.2 
 
            Special earthing provisions and instructions 
for equipment with high touch current due to 
telecommunication network connections. 
           
 
             
           
N/A 
5.1.8.3 
 
            Touch current due to ringing voltage for 
equipment containing telecommunication network 
leads. 
           
 
             
           
N/A 
5.3.7 
 
            Overloading of SELV connectors and 
printed wiring board receptacles accessible to the 
operator. 
           
 
             
           
Pass 
5.3.7 
 
            Tests interrupted by opening of a 
component repeated two additional times. 
           
 
             
           
N/A 
5.3.9.1 
 
            Test interrupted by opening of wire or trace 
subject to certain conditions. 
           
 
             
           
N/A 
 
            Specialized instructions provided for 
telephones that may be connected to a 
telecommunications network. 
           
 
             
           
N/A 
 
            Marking identifying function of 
telecommunication type connectors not used for 
connection to a telecommunication network. 
           
 
             
           
N/A 
6.3 
 
            Equipment remotely powered over 
telecommunication wiring systems provided with 
specialized markings adjacent to the connection. 
           
 
             
           
N/A 
6.3 
 
            Overcurrent protection incorporated into 
 
             
N/A 
Issue Date: 
2013-01-09 
Page 38 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
equipment to provide power over 
telecommunication wiring system not 
interchangeable with devices of higher ratings if 
operator replaceable. 
           
           
6.4 
 
            Additional requirements for equipment 
intended for connection to a telecommunication 
network using cable subject to overvoltage from 
power line failures (Fig. 6C). 
           
 
             
           
N/A 
6.4 
 
            Where 26 AWG line cord required by Fig. 
6C, either the cord is provided with the equipment 
or described in the safety instructions. 
           
 
             
           
N/A 
 
            Equipment associated with the cable 
distribution system may need to be subjected to 
applicable parts of Chapter 8 of the NEC. 
           
 
             
           
N/A 
 
            Ionizing radiation measurements made 
under single fault conditions in accordance with the 
requirements of the Code of Federal Regulations 
21 CFR 1020 and the Canadian Radiation Emitting 
Devices Act, REDR C1370. 
           
 
             
           
N/A 
M.2 
 
            Continuous ringing signals evaluated to 
Method A subjected to special accessibility 
considerations. 
           
 
             
           
N/A 
M.4 
 
            Special requirements for message waiting 
and similar telecommunications signals. 
           
 
             
           
N/A 
NAC 
 
            Equipment intended for use with a generic 
secondary protector marked with suitable 
instructions. 
           
 
             
           
N/A 
NAC 
 
            Equipment intended for use with a specific 
 
             
N/A 
Page of 116