Issue Date: 
2013-01-09 
Page 23 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
           
6.1.2.1 
 
            Add the following text between the first and 
second paragraph of the compliance clause: 
If this insulation is solid, including insulation 
forming part of a component, it shall at least consist 
of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below. 
 
Alternatively for components, there is no distance 
through insulation requirement for the insulation 
consisting of an insulating compound completely 
filling the casing, so that CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the 
component passes the electric strength test in 
accordance with the compliance clause below and 
in addition 
- passes the tests and inspection criteria of 2.10.11 
with an electric strength test of 1,5 kV multiplied by 
1,6 (the electric strength test of 2.10.10 shall be 
performed using 1,5 kV), and 
- is subject to ROUTINE TESTING for electric 
strength during manufacturing, using a test voltage 
of 1,5 kV. 
 
It is permitted to bridge this insulation with an 
optocoupler complying with 2.10.5.4 b). 
 
It is permitted to bridge this insulation with a 
capacitor complying with EN 132400:1994, 
subclass Y2. 
A capacitor classified Y3 according to EN 132400 
[EN 60384-14:2005], may bridge this insulation 
under the following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by EN 
132400 [EN 60384-14], which in addition to the Y3 
testing, is tested with an impulse test of 2,5 kV 
defined in EN 60950-1:2006, 6.2.2.1; 
- the additional testing shall be performed on all the 
test specimens as described in EN 132400 [EN 
60384-14]; 
- the impulse test of 2,5 kV is to be performed 
 
             
           
N/A 
Issue Date: 
2013-01-09 
Page 24 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
before the endurance test in EN 132400 [EN 
60384-14], in the sequence of tests as described in 
EN 132400 [EN 60384-14.] 
           
6.1.2.2 
 
            The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT and 
PLUGGABLE EQUIPMENT TYPE B and 
equipment intended to be used in a RESTRICTED 
ACCESS LOCATION where equipotential bonding 
has been applied, e.g. in a telecommunication 
centre, and which has provision for a permanently 
connected PROTECTIVE EARTHING 
CONDUCTOR and is provided with instructions for 
the installation of that conductor by a SERVICE 
PERSON. 
           
 
             
           
N/A 
7.2 
 
            Requirements according to this annex, 
6.1.2.1 and 6.1.2.2 apply with the term 
TELECOMMUNICATION NETWORK in 6.1.2 
being replaced by the term CABLE DISTRIBUTION 
SYSTEM. 
           
 
             
           
N/A 
7.3 
 
            Requirements according to this annex 
1.2.13.14 and 1.7.2.1 apply. 
           
 
             
           
N/A 
 
Issue Date: 
2013-01-09 
Page 25 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
Switzerland - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009  
 
3.2.1.1 
 
            Supply cords of equipment having a 
RATED CURRENT not exceeding 10A shall be 
provided with a plug complying with SEV 1011 or 
IEC 60884-1 and one of the following dimension 
sheets: 
SEV 6532-2 1991 
Plug Type 15 
3P+N+PE 250/400 V, 10A 
SEV 6533-2 1991 
Plug Type 11 
L+N 
 
250 V, 10A 
SEV 6534-2 1991 
Plug Type 12 
L+N+PE  250V, 10A 
In general, EN 60309 applies for plugs for currents 
exceeding 10A.  However, a 16A plug and socket-
outlet system is being introduced in Switzerland, 
the plugs of which are according to the following 
dimension sheets, published in February, 1998.   
SEV 5932-2 1998:Plug Type 25 
3L+N+PE 230/400V, 16A 
SEV 5933-2 1998:Plug Type 21 
L+N 
 
250 V, 16A 
SEV 5934-2 1998:Plug Type 23    L+N+PE 
250 V, 16A 
           
 
             
           
N/A 
3.2.4 
 
            Requirements according to this annex 
3.2.1.1 apply. 
           
 
             
           
N/A 
 
Issue Date: 
2013-01-09 
Page 26 of 41 
Report Reference # 
E204594-A39-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
USA / Canada - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009  
 
1.1 
 
            Equipment able to be installed in 
accordance with the National Electrical Code 
ANSI/NFPA 70 and the Canadian Electrical Code, 
Part1, and when applicable, the National Electrical 
Safety Code, IEEE C2. 
           
 
             
           
Pass 
1.1.1 
 
            Equipment able to be installed in 
accordance with ANSI/NFPA 75 and NEC Art. 645 
unless intended for use outside of computer room 
and provided with such instructions. 
           
 
             
           
Pass 
1.1.2 
 
            Equipment in wire-line communication 
facilities serving high-voltage electric power 
stations operating at greater than 1kV are 
excluded. 
           
 
             
           
N/A 
1.1.2 
 
            Special requirements apply to equipment 
intended for use outdoors. 
           
 
             
           
N/A 
1.4.14 
 
            For PLUGGABLE EQUIPMENT TYPE A, 
the protection in the installation is assumed to be 
20 A. 
           
 
             
           
N/A 
1.5.1 
 
            All IEC standards for components identified 
in Annex P.1 replaced by the relevant requirements 
of CSA and UL component standards in Annex P.1. 
           
 
             
           
Pass 
1.5.1 
 
            All IEC standards for components identified 
in Annex P.2 alternatively satisfied by the relevant 
requirements of CSA and UL component standards 
in Annex P.2. 
           
 
             
           
Pass 
1.5.5 
 
            Interconnecting cables acceptable for the 
application regarding voltage, current, temperature, 
flammability, mechanical serviceability and the like. 
 
             
           
N/A 