JBL ON BEAT RUMBLE (serv.man2) EMC - CB Certificate ▷ View online
Report No.: EM201200813-6 Application No.: ZJ00024740 Page 45 of 61
5.6.4 TEST RESULTS
EUT
Wireless high-power speaker for lighting connector
Mode Number
JBL OnBeat Rumble
Test date
2013-01-04
Voltage Supply
AC 230V/50Hz
Test Engineer
Liang
environment
Tem:21℃ Hum:50 %100kPa
Test mode:
1. Test the EUT in BT, BT(Loading), BT (Headset),BT(Headset and
Loading), Audio in, Audio in (Loading), Audio in (Headset), Audio in
(Headset and Loading), iPhone5, iPhone5 (Loading), iPhone5 (Headset),
iPhone5 (Headset and Loading);
(Headset and Loading), iPhone5, iPhone5 (Loading), iPhone5 (Headset),
iPhone5 (Headset and Loading);
2. Test the EUT in idle mode.
Test Point Polarity
Test
Level
(kV)
Phase
Performanc
e
Criterion
Actual
performanc
e
Result
(P/F)
L - N
+/- 1 0° B
A
PASS
+/- 1 90° B
A
PASS
+/- 1
180° B
A
PASS
+/- 1
270° B
A
PASS
A*: There was no change compared with the initial operation during the test.
Report No.: EM201200813-6 Application No.: ZJ00024740 Page 46 of 61
5.7 INJECTED CURRENTS SUSCEPTIBILITY TEST
5.7.1 TEST SPECIFICATION
Basic Standard
EN 61000-4-6:2009
Frequency Range
0.15 MHz-80 MHz
Field Strength
3 V
Modulation
1 kHz,80% AM
Frequency Step
1%
Dwell time
2s
5.7.2 TEST PROCEDURE
1) Set up the EUT, CDN as shown on Section 5.7.3
2) Let the EUT work in test mode and measure it.
3) The EUT are placed on an insulating support 0.1m high above a ground reference plane. CDN
2) Let the EUT work in test mode and measure it.
3) The EUT are placed on an insulating support 0.1m high above a ground reference plane. CDN
(coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables
between CDN and EUT are as short as possible, and their height above the ground reference
plane shall be between 30 and 50 mm (where possible).
between CDN and EUT are as short as possible, and their height above the ground reference
plane shall be between 30 and 50 mm (where possible).
4) The disturbance signal described below is injected to EUT through CDN.
5) The EUT operates within its operational mode(s) under intended climatic conditions after
5) The EUT operates within its operational mode(s) under intended climatic conditions after
power on.
6) The frequency range is swept from 150 kHz to 80MHz using 3V signal level, and with the
disturbance signal 80% amplitude modulated with a 1 kHz sine wave.
7) The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept
incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding
frequency value.
frequency value.
8) Recording the EUT operating situation during compliance testing and decide the EUT
immunity criterion.
Report No.: EM201200813-6 Application No.: ZJ00024740 Page 47 of 61
5.7.3 TEST SETUP
Report No.: EM201200813-6 Application No.: ZJ00024740 Page 48 of 61
5.7.4 TEST RESULTS
EUT
Wireless high-power speaker for lighting connector
Mode Number
JBL OnBeat Rumble
Test date
2013-01-04
Voltage Supply
AC 230V/50HZ
Test Engineer
Liang
environment
Tem:22℃ Hum:51 %100kPa
Test mode:
1. Test the EUT in BT, BT(Loading), BT (Headset),BT(Headset and
Loading), Audio in, Audio in (Loading), Audio in (Headset), Audio in
(Headset and Loading), iPhone5, iPhone5 (Loading), iPhone5
(Headset), iPhone5 (Headset and Loading);
(Headset and Loading), iPhone5, iPhone5 (Loading), iPhone5
(Headset), iPhone5 (Headset and Loading);
2. Test the EUT in idle mode.
Frequency
Band (MHz)
Field
Strength
(Vrms)
Cable
Injection
Method
Required
Passing
Performance
Actual
performance
Result
0.15-80
3
AC Line CDN-M2/M3 Criterion A Criterion A*
PASS
A*: There was no change compared with initial operation during the test.
Click on the first or last page to see other ON BEAT RUMBLE (serv.man2) service manuals if exist.