EMC - CB Certificate
Brand
Device
Audio
File
on-beat-rumble-sm2.pdf
Date

JBL ON BEAT RUMBLE (serv.man2) EMC - CB Certificate ▷ View online

Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 49 of 61 
 
 
5.8 VOLTAGE DIP & VOLTAGE INTERRUPTIONS 
5.8.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-11:2004 
Test duration time 
Voltage dips: 
30 during 25 periods, 
Meets the requirements of  Performance Criterion C 
Voltage interruption: 
100% during 0.5 cycles, 
100% during 1 cycles, 
Meets the requirements of Performance Criterion B 
100% during 250 cycles, 
Meets the requirements of Performance Criterion C 
Interval between event 
10s for each dips at each test angle 
Phase Angle 
 
Test cycle 
 
5.8.2 TEST PROCEDURE  
a) The EUT and test generator were setup as shown on Section  
b) The interruptions is introduced at selected phase angles with specified duration. 
c)  Record any degradation of performance. 
5.8.3 TEST SETUP 
                                                
 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 50 of 61 
 
 
5.8.4 TEST RESULTS 
EUT 
Wireless high-power speaker for lighting connector 
Mode Number 
JBL OnBeat Rumble 
Test date 
2013-01-04 
Voltage Supply 
AC 230V/50HZ 
Test Engineer 
Liang 
environment 
Tem:20℃ Hum:51 %100kPa 
Test mode: 
1. Test the EUT in BT, BT(Loading), BT (Headset),BT(Headset and 
Loading), Audio in, Audio in (Loading), Audio in (Headset), Audio in 
(Headset and Loading), iPhone5, iPhone5 (Loading), iPhone5 
(Headset), iPhone5 (Headset and Loading); 
2. Test the EUT in idle mode. 
 
Voltage 
( Reduction) 
Duration 
(Period) 
Angle 
Actual 
performance 
Test Result
Voltage 
dips 
30% 25  0°  A* PASS 
Voltage 
interruptions 
100% 0.5  0°  A*  PASS 
Voltage 
interruptions 
100% 1  0°  A* PASS 
Voltage 
interruptions 
100% 250  0°  C*  PASS 
Note: A*: There was no change compared with initial operation during the test. 
C* is within the acceptable criterion for Voltage Dips and Interruption test. 
 
 
 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 51 of 61 
 
APPENDIX A: PHOTOGRAPH OF THE TEST CONFIGURATION
 
RE (Blowe 1GHz) 
 
 
RE (Above 1GHz) 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 52 of 61 
 
CE 
 
 
Flicker 
Page of 61