Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 41 of 61 
 
 
5.4.4 TEST RESULTS 
EUT 
Wireless high-power speaker for lighting connector 
Mode Number 
JBL OnBeat Rumble 
Test date 
2013-01-04 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Liang 
environment 
Tem:23℃ Hum:48 %100kPa 
Test mode: 
1. Test the EUT in BT, BT(Loading), BT (Headset),BT(Headset and 
Loading), Audio in, Audio in (Loading), Audio in (Headset), Audio in 
(Headset and Loading), iPhone5, iPhone5 (Loading), iPhone5 
(Headset), iPhone5 (Headset and Loading); 
2. Test the EUT in idle mode. 
 
Frequency  
(MHz) 
Polarity 
Azimuth 
Field 
Strength
(V/m)
Required 
Passing 
Performance 
Actual 
performance
Result
80 ~ 1000 
V&H 
Front 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Rear 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Right 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Left 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Front 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Rear 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Right 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Left 
Criterion A 
Criterion A* PASS
A*There was no change compared with the initial operation during the test. 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 42 of 61 
 
 
5.5 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 
5.5.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-4: 2004+A1: 2010 
Test Voltage 
Electrical Fast Transient/Burst – EFT: 
AC Power Port: ±1kV,Signal port ±0.5kV 
Performance Criterion B 
Polarity 
Positive and Negative 
Impulse Frequency 
5 kHz 
Impulse Wave-shape 
5 ns/50ns for voltage  
Burst Duration 
15 ms 
Burst Period 
300 ms 
Test Duration 
2 minutes 
5.5.2 TEST PROCEDURE  
 
The EUT and its simulators shall be placed 0.1m high above the ground reference plane which is a min. 
1m×1m metallic sheet with 0.65mm minimum thickness. This reference ground plane shall project 
beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other 
conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m. 
For input and AC power ports
The EUT is connected to the power mains by using a coupling device which couples the EFT 
interference signal to AC power lines. Both polarities of the test voltage should be applied during 
compliance test and the duration of the test can’t less than 1min. 
5.5.3 TEST SETUP 
 
 
 
 
 
10 cm isolation 
supporter 
AC
 input 
EFT 
Generator 
EUT 
AC
  
AC Line 
Ground Reference Plane 
0.5m
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 43 of 61 
 
 
5.5.4 TEST RESULTS 
EUT 
Wireless high-power speaker for lighting connector 
Mode Number 
JBL OnBeat Rumble 
Test date 
2013-01-04 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Liang 
environment 
Tem:21℃ Hum:50 %100kPa 
Test mode: 
1. Test the EUT in BT, BT(Loading), BT (Headset),BT(Headset and 
Loading), Audio in, Audio in (Loading), Audio in (Headset), Audio in 
(Headset and Loading), iPhone5, iPhone5 (Loading), iPhone5 (Headset), 
iPhone5 (Headset and Loading); 
2. Test the EUT in idle mode. 
 
Test Point 
Polarity 
Test Level 
(kV) 
Required Passing 
Performance 
Actual 
performance 
Result 
+/- 
Criterion B 
Criterion A* 
PASS 
+/- 
Criterion B 
Criterion A* 
PASS 
L–N 
+/- 
Criterion B 
Criterion A* 
PASS 
A*There was no change compared with the initial operation during the test. 
 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 44 of 61 
 
 
5.6 SURGE IMMUNITY TEST 
5.6.1 TEST SPECIFICATION 
Basic Standard:  
EN 61000-4-5:2006 
Wave-Shape: 
CW 1.2µs/50µs 
Test Voltage: 
Line to line 0.5kV; line to PE 1kV 
Generator Source Impedance: 
Line to line 2ohm; line to PE 12ohm 
Polarity: 
Positive and Negative 
Phase Angle: 
0°, 90°, 180°, 270° 
Pulse Repetition Rate: 
60s 
Number of Tests: 
5 times 
5.6.2 TEST PROCEDURE  
a)  For EUT power supply: 
The surge is applied to the EUT power supply terminals via the capacitive coupling network. Decoupling 
networks are required in order to avoid possible adverse effects on equipment not under test that may be 
powered by the same lines, and to provide sufficient decoupling impedance to the surge wave. The power 
cord between the EUT and the coupling/decoupling networks was shorter than 2 meters in length. 
b)  For test applied to unshielded un-symmetrically operated interconnection lines of EUT: The surge was 
applied to the lines via the capacitive coupling. The coupling / decoupling networks didn’t influence the 
specified functional conditions of the EUT. The interconnection line between the EUT and the 
coupling/decoupling networks was shorter than 2 meters in length. 
c) For test applied to unshielded symmetrically operated interconnection / telecommunication lines of 
EUT:The surge was applied to the lines via gas arrestors coupling. Test levels below the ignition point of 
the coupling arrestor were not specified. The interconnection line between the EUT and the 
coupling/decoupling networks was shorter than 2 meters in length. 
5.6.3 TEST SETUP 
 
Page of 61